* The 1986 COSMOS FILES *
|
||
* PART III: Service Order Input *
|
||
* Written by: *
|
||
* *
|
||
* SIR WILLIAM *
|
||
* [KOTRT] *
|
||
* *
|
||
***************************************
|
||
|
||
|
||
|
||
The 1986 COSMOS FILE series consists of 6 parts, including the introduction,
|
||
covering all major Service Orders, Work Orders, Reports, Facility and Circuit
|
||
Alteration, COSMOS-N/PREMIS transactions and a complete list of all the
|
||
facility prefixes. The 1986 file series is intended for the serious COSMOS
|
||
hacker. (Not too serious)
|
||
|
||
NOTE: The content of this material is proprietary and constitutes a trade
|
||
secret. It is furnished pursuant to written agreements or instructions
|
||
limiting the extent of its disclosure. Its further disclosure in any form
|
||
without the permission of its owner, Western Electric Co. Inc., is prohibited.
|
||
hi ho.
|
||
|
||
DISCLAIMER: I take full responsibility for all deaths, physical injuries,
|
||
emotional stress, and monetary damages as a result of this file.
|
||
Please send all claims to KOTRT Enterprises, P.O. Box 1223-232,
|
||
Wunderland, N. Ireland 928301
|
||
|
||
***************************************
|
||
INTRO TO SERVICE ORDER INPUT
|
||
***************************************
|
||
|
||
Under COSMOS software version 8.X there are new input procedures for SOE's.
|
||
Although these are mostly in the area of error handling, they require a bit
|
||
of discussion, seperate from the basic input.
|
||
|
||
Error Handling
|
||
--------------
|
||
Service order transactions interact with the user more frequently in
|
||
REV 8.X. Each time the transaction is ready for a new input, it will
|
||
respond with and underscore "_" at the beginning of the new line. This
|
||
indicates that the preceding line is correct.
|
||
If an error does occur, the transaction will respond with an error
|
||
message and prompt for correction. When an error occurs, you have
|
||
4 choices.
|
||
1. Re-enter the entire field correctly.
|
||
2. Enter line-feed to ignore, (checks rest of line)
|
||
3. Enter a ";" to disregard the present circuit.
|
||
4. Enter a "." the transaction will disregard all input, and exit.
|
||
|
||
H-LINE inputs.
|
||
--------------
|
||
H-LINE input for the service order trio SOE/CSA/TSA is being rigidly
|
||
defined in 8.0 according to three categories. These categorys contain
|
||
fundamentally different types of order/facility information.
|
||
Category 1: ORD, OT, DD, FDD,J OC, DT, SG, EO, LC
|
||
Category 2: US, FEA, CCF, CAT, BTN, SS, AO, RZ, FR, GP/CG, CTX/CG/MG/NNX,
|
||
LDN, RTI.
|
||
Category 3: FW, RW
|
||
Category 1 items are primary, once defined they cannot be changed
|
||
by conflicting category 2, and 3 lines.
|
||
|
||
SERVICE ORDER TRANSACTIONS
|
||
|
||
Transaction Definition
|
||
=========== ======================
|
||
SOE Service Order Input
|
||
TDZ Telephone Number Assignment lists
|
||
LDZ Line Equipment Assignment list
|
||
SOH Service Order withheld
|
||
SOM Service Order Modification
|
||
SOC Service Order Cancellation
|
||
SOW Service Order Withdraw
|
||
SCM Service Order Completion by MDF
|
||
SCP Service Order Completion by PAO
|
||
SCA Service Order Completion - Automatic
|
||
SCF Service Order Completion for MDF automatic
|
||
SCI Spare Cable pair inquiry
|
||
CDD Change Due Date
|
||
BAI Bridge Lifter Assignment Inquiry
|
||
LAI Line Equipment Assignment Inquiry
|
||
NAI Telephone Numbers Assignment Inquiry
|
||
TAI Tie pair assignment Inquiry
|
||
EDZ Facility Emergency Assignment list for backup
|
||
MAP Manual Assignment Parameters
|
||
MAL Manual Assignment list
|
||
TSW Total Service Order Withdraw
|
||
|
||
***************************************
|
||
TRANSACTIONS DEFINED
|
||
***************************************
|
||
|
||
SOE - Service Order Establishment
|
||
- Establishes a pending service order. The types of orders are; NC, CD,
|
||
CH, F, T, SS, RS, R, RF. Reassociations are treated as change orders.
|
||
- H-lines must contain ORD, DD, and OT. Optional facilities; FW, RW, FDD
|
||
AO, FR, SG, and either DT or OC.
|
||
- I and O lines may contain; US, FEA, CP, OE, TN, RZ, NNX, PL, TP, TK, BL, # SE, CON, MR, BTN, RC, RE, RT,STC, STN, STO, CCF, LCC, and RTI.
|
||
- ESS orders requiring coordination by the recent change input center may # be flagged with an input of "RW C".
|
||
Example of a NC [New Connect]
|
||
WC% SOE
|
||
H ORD NCXXXXXX/DD 01-01-86/OT NC/FDD 02-05-86/DT AM
|
||
_I CP XXXXX-XXXXXX/OE ?/TN ?/US 2FR/FEA RNNL
|
||
_.
|
||
|
||
Example of a CD [Complete Disconnect]
|
||
WC% SOE
|
||
H ORD CDXXXXXX/DD 01-01-85/OT CD
|
||
_O TN 534-1822
|
||
_.
|
||
|
||
Example of a CH [Change]
|
||
WC% SOE
|
||
H ORD CHXXXXX/OT CH/DD 01-01-86/TN 534-1822
|
||
_O TN 534-1822/STN CO
|
||
_I TN ?
|
||
_.
|
||
Example of SS [Suspension]
|
||
WC% SOE
|
||
H ORD SSXXXXX/OT SS/DD 01-01-86
|
||
_O TN 534-1822/SS SB
|
||
_.
|
||
|
||
TDZ - Telephone Number Assignments List
|
||
- List the indicated number of spare directory numbers for a NNX code, and
|
||
directory number type.
|
||
- Up to 25 directory numbers can be specified, using the prefix LC.
|
||
Example
|
||
WC% TDZ
|
||
H NNX 534/TT G/LC 7 (LC can be up to 25)
|
||
.
|
||
Output example would look similar to this.
|
||
**EMERGENCY FACILITY ASSIGNMENT LIST 01-01-86
|
||
RESERVED LINE EQUIPMENT
|
||
**NO SPARE LINE EQUIPMENT FOUND
|
||
AVAILABLE DIRECTORY NUMBERS (7)
|
||
534-XXXX
|
||
534-XXXX, etc.
|
||
**TRANSACTION COMPLETED
|
||
|
||
SOW - Service Order Withdraw
|
||
- Withdraws most recent version of a service order
|
||
- Order number must refer to the latest version. The H-line circuit ID
|
||
identifys the order. Valid circuit identifiers are; TN, XN, PL, CP, OE,
|
||
and TK.
|
||
Example
|
||
WC% SOW
|
||
H ORD NC-XXXXX/TN 534-1822
|
||
.
|
||
|
||
SCP - Service Order Completion by PAO
|
||
- Record in the Service Order File the completion of an order by PAO
|
||
- Standard SXX H line input.
|
||
Example
|
||
WC% H ord CDXXXXXX/TN 534-1822
|
||
.
|
||
|
||
SCA - Service Order Completion Automatic
|
||
- Enters final completion on all service orders which have been or are
|
||
not requried to be completed by the MDF, are not in a held, or jeopardy
|
||
status, and are due prior to or on the current date.
|
||
- Two due dates may be entered on the H-line; SCA will complete orders due # on or between the dates. Additional options are OT (order type), ORD,
|
||
and SG.
|
||
Example
|
||
WC% SCA
|
||
. :complete all orders on or before this due date
|
||
|
||
Example2
|
||
WC%SCA
|
||
H DD 01-01-86/OT NC :Complete all NC (new connect) orders
|
||
.
|
||
|
||
|
||
CDD - Change Due Date
|
||
- Change due date of a service or frame order
|
||
- I think an example will suffice;
|
||
WC% CDD
|
||
H ORD CH-XXXXXX/TN 534-1822
|
||
I DD 01-01-86
|
||
.
|
||
output example
|
||
**ORD CH-XXXXX DUE DATE 01-01-86
|
||
|
||
|
||
NAI - Telephone Number Assignment Inquiry
|
||
- Provides from 1 to 25 spare telephone numbers compatable with the
|
||
input specifications.
|
||
- Input is an H-line with the TN type and NNX or RZ entries. The status of
|
||
the TN supplied will be modified to reserved if ST is specified on the H-# line.
|
||
Example
|
||
WC% NAI
|
||
H TT X/NNX 534/ST RS
|
||
.
|
||
this shows first available spare in prefix 534.
|
||
|
||
MAP - Manual Assignment Parameter
|
||
- Permits the PAO to establish the parameters that will constitute the PAO # Open-of-Day report.
|
||
WC% MAP
|
||
I NNX 534/ECS 1R/EQF TNNL/LC 50, etc. (for line equipment)
|
||
I NNX 534/TT B/LC 10 (For Telephone numbers of type B, 10)
|
||
etc.
|
||
|
||
==============================================================
|
||
[C]OPYRIGHT 1986. KOTRT ENTERPRISES. WUNDERLAND, S. AFRICA
|
||
==============================================================
|
||
|
||
|
||