AST RESEARCH TECHNICAL BULLETIN TB-0182B 6-30-86
|
||
|
||
|
||
CC432 WRAP PLUG
|
||
|
||
|
||
When running the diagnostics program 'CC432TEST' on the AST CC432
|
||
board, it is required that you install the shorting plugs at
|
||
positions 2, 4 and 8. (Reference Users Manual part number
|
||
000140-001, April 1984, page 5-3.) Since these shorting plugs
|
||
are at 1, 3 and 8 when you are running emulation, it is necessary
|
||
to remove the cover of the PC and change these shorting plugs
|
||
before you can run diagnostics. Some users find this
|
||
inconvenient. The following is a wiring configuration for the
|
||
wrap plug part number 202034-001 which will allow you to run
|
||
diagnostics without having to move the shorting plugs to 2, 4
|
||
and 8:
|
||
|
||
Connect Pins
|
||
2 to 3
|
||
4 to 5 to 22
|
||
6 to 8 to 20
|
||
15 to 17 to 24
|
||
|
||
Then follow the normal test procedures outlined in Section 5.4,
|
||
pages 5-4 thru 5-9.
|
||
|
||
NOTE: As a portion of the data is in pictorial form, it is not
|
||
included here. To obtain a complete copy of this
|
||
technical bulletin, contact:
|
||
|
||
AST RESEARCH, INC.
|
||
2121 Alton Avenue
|
||
Irvine, California 92714-4992
|
||
|
||
Attention: Product Support
|
||
(Technical Bulletin)
|
||
|