AST RESEARCH TECHNICAL BULLETIN TB-0182B 6-30-86
CC432 WRAP PLUG
When running the diagnostics program 'CC432TEST' on the AST CC432
board, it is required that you install the shorting plugs at
positions 2, 4 and 8. (Reference Users Manual part number
000140-001, April 1984, page 5-3.) Since these shorting plugs
are at 1, 3 and 8 when you are running emulation, it is necessary
to remove the cover of the PC and change these shorting plugs
before you can run diagnostics. Some users find this
inconvenient. The following is a wiring configuration for the
wrap plug part number 202034-001 which will allow you to run
diagnostics without having to move the shorting plugs to 2, 4
and 8:
Connect Pins
2 to 3
4 to 5 to 22
6 to 8 to 20
15 to 17 to 24
Then follow the normal test procedures outlined in Section 5.4,
pages 5-4 thru 5-9.
NOTE: As a portion of the data is in pictorial form, it is not
included here. To obtain a complete copy of this
technical bulletin, contact:
AST RESEARCH, INC.
2121 Alton Avenue
Irvine, California 92714-4992
Attention: Product Support
(Technical Bulletin)