Inpho on Automatic Line Testers
|
|||
|
Typed By RiPMaX/LIBERTY
|
|||
|
|
|||
|
DOC NO: [2/4]
|
|||
|
|
|||
|
AUTOMATICE LINE TESTERS - S.A.L.T.
|
|||
|
|
|||
|
GENERAL
|
|||
|
-------
|
|||
|
|
|||
|
The S.A.L.T. (Subscriber Automatic Line Tester) is installed in exchanges to
|
|||
|
provide automatic testing facilities for telephones and line conditions on
|
|||
|
exchange services.
|
|||
|
After clearing the fault it is neccessary to test the complete telephone
|
|||
|
service including the insulation resistance on the line to earth and between
|
|||
|
the pair, the bell and dial operation.
|
|||
|
Access to the S.A.L.T. testing equipment is obtained by dialing the special
|
|||
|
number allotted to the particualr exchange. It is only neccessary to obtain
|
|||
|
access to the S.A.L.T. tester once. All subsequent tests may be made by
|
|||
|
dialing the code digit for that test. The following tests may be preformed in
|
|||
|
any order or independantly of each other without the need to release the
|
|||
|
tester.
|
|||
|
|
|||
|
TO OBTAIN ACCESS TO S.A.L.T. TESTER
|
|||
|
-----------------------------------
|
|||
|
|
|||
|
Dial the access code number for the particular exchange.
|
|||
|
|
|||
|
* If the tester is free ring tone will be heard.
|
|||
|
* If no tone is heard wait for busy tone, hang up and try again.
|
|||
|
* If the tester becomes free while waiting, ring tone will be heard.
|
|||
|
|
|||
|
Hang up and wait for telephone bell to ring ( About 4 seconds ).
|
|||
|
|
|||
|
Lift receiver on ring back. If dial tone is heard the circuit is ready for
|
|||
|
testing to proceed.
|
|||
|
|
|||
|
The S.A.L.T. is released when the handset is replaced after a test.
|
|||
|
|
|||
|
INSULATION RESISTANCE TESTS A> A TO B B> A AND B TO EARTH
|
|||
|
-----------------------------------------------------------
|
|||
|
|
|||
|
This is a combination test which tests both the insulation resistance between
|
|||
|
the pair and the insulation resisitance to earth.
|
|||
|
|
|||
|
Dial 5 and listen for ring tone.
|
|||
|
Hang up and wait for telephone bell to ring.
|
|||
|
Lift receiver on ring back.
|
|||
|
Listen to tone :
|
|||
|
|
|||
|
* 900 Hz = Line OK (I * R Over 1M<31>)
|
|||
|
* Busy Tone = Line Faulty (I * R between 0.5M<EFBFBD> and 1M<31>)
|
|||
|
* NU Tone = Line Faulty (I * R below 0.5M<EFBFBD>)
|
|||
|
|
|||
|
If the service fails this test, use code digits 6 and/or 7 to isolate the
|
|||
|
problem.
|
|||
|
|
|||
|
INSULATION RESISTANCE, A TO EARTH AND B TO EARTH
|
|||
|
------------------------------------------------
|
|||
|
|
|||
|
Dial 6 and LIsten for ring tone.
|
|||
|
Continue as for Insulation resistance tests. (Code digit 5)
|
|||
|
|
|||
|
INSULATION RESISTANCE, A TO B
|
|||
|
-----------------------------
|
|||
|
|
|||
|
Dial 7 and LIsten for ring tone.
|
|||
|
Continue as for Insulation resistance tests. (Code digit 5)
|
|||
|
|
|||
|
LINE LOOP RESISTANCE TEST
|
|||
|
-------------------------
|
|||
|
|
|||
|
Dial 8.
|
|||
|
Listen to tone :
|
|||
|
|
|||
|
* 900 Hz = Line OK
|
|||
|
* Busy Tone = Loop resistance too high
|
|||
|
* NU Tone = Loop resistance 200<30> or less.
|
|||
|
|
|||
|
DIAL TEST
|
|||
|
---------
|
|||
|
|
|||
|
Dial 1 and listen for ring tone, then dial "0".
|
|||
|
Listen to tone :
|
|||
|
|
|||
|
* 0.5 seconds 900 Hz tone then ring tone = Dial OK.
|
|||
|
* NU Tone = Pulse Faulty (Replace)
|
|||
|
|
|||
|
BELL TEST (FULL VOLTAGE)
|
|||
|
------------------------
|
|||
|
|
|||
|
Dial 4 and Listen for ring tone.
|
|||
|
Hang up and ring back in 4 to 5 seconds.
|
|||
|
Lift receiver to trip ring.
|
|||
|
|
|||
|
BELL TEST (HALF VOLTAGE)
|
|||
|
------------------------
|
|||
|
|
|||
|
Dial 4 and Listen for ring tone.
|
|||
|
Continue as for full voltage test.
|
|||
|
|
|||
|
TEST CONTROL FOR S.A.L.T.
|
|||
|
|
|||
|
Dial 9 and listen for dial tone, which indicates that the testing equipment is
|
|||
|
functioning correctly. This test may be done at anytime time after access to
|
|||
|
the S.A.L.T. has been obtained. Hang up to release the testing equipment.
|
|||
|
|
|||
|
*******************************************************************************
|
|||
|