In article <8209@watdaisy.UUCP> dvadura@watdaisy.UUCP (Dennis Vadura) writes:
>Can anyone out there point
>me to someplace that I can find a detailed description of the format of
>a .exe file. I need to know all the fields, their meanings, and their
>offsets from the start of the file. Any help will be greatly appreciated.
OK, here it is. The following is from the IBM Personal Computer
Software Disk Operating System Technical Reference, v2.10, 3.00 and
3.10, pp 10-3 to 10-6:
-- cut here --
EXEILE STRUCTURE
The .EXE files produced by the Linker program consist of two parts:
* Control and relocation information
* The load module itself
The control and relocation information, which is described below, is
at the beginning of the file in an area known as the _header_. The
load module begins in the memory image of the modlue constructed by
the Linker.
The header is formatted as follows:
HEX OFFSET CONTENTS
00-01 4DH, 5AH -- this is the Link program's signature to
mark the file as a valid .EXE file.
02-03 Length of image mod 512 (remainder after dividing the
load module image size by 512).
04-05 Size of the file in 512-byte increments (pages),
including the header.
06-07 Number of relocation table items.
08-09 Size of theeader in 16-byte increments (paragraphs).
This is used to locate the beginning of the load
module in the file.
0A-0B Minimum number of 16-byte paragraphs required above
the end of the loaded program.
0C-0D Maximum number of 16-byte paragraphs required above
the end of the loaded program.
0E-0F Displacement in paragraphs of stack segment within load
module.
10-11 Offset to be in the SP register when the module is
given control.
12-13 Word checksum -- negative sum of all of the words in
thefile, ignoring overflow.
14-15 Offset to be in the IP register when the module is given
control.
16-17 Displacement in paragraphs of code segment within load
module.
18-19 Displacement in bytes of the first relocation item
within the file.
1A-1B Overlay number (0 for resident part of the program).
NOTE: Use the value at hex offset 18-19 to locate the first entry in
the relocation table.
RELOCATION TABLE
The word at 18H locates the first entry in the relocation table. The
relocation table is made up of a variable number of relocation items.
The number of items is contained at offset 06-07. The relocation item
contains two fields -- a 2-byte offset value, followed by a 2-byte
segment value. These two fields represent the displacement into the
load module of a work which requires modification before the module is
given control. This process is called _relocation_ and is
accomplished as follows:
1. A program segment prefix is built following the resident portion
of the program that is performing the load operation.
2. The formatted part of the header is read in memory (it's size is
at offset 08-09).
3. The load module size is determined by subtracting the header size
more - return to continue, Q to quit
from the file size. Offsets 04-05 and 08-09 can be used for this
calculation. The actual size is downward adjusted based on the
contents of offsets 02-03. Note that all files created by Link
programs prior to version 1.10 _always_ placed a value of 4 at that
location, regardless of actual program size. Therefore, we recommend
that this field be ignored if it contains a value of 4. Based on the
setting of the high/low loader switch, an appropriate segment is
determined at which to load the load module. This segment is called
the _start_segment_.
4. The load module is read into memory beginning at the start
segment. Note: The relocation table is an unordered list of
relocation items. The first relocation item is the one that has the
lowest offset in the file.
5. The relocation items are read into a work area (one of morat a
time).
6. Each relocation table item segment value is added to the start
segment value. This calculated segment, in conjunction with the
relocation item offset value, points to a word in the load module
to which is added the start segment value. The result is placed back
into the word in the load module.
7. Once all relocation items have been processed, the SS and SP
registers are set from the values in the header and the start segment
value is added to SS. The ES and DS registers are set to the segment
address of the program segment prefix. The start segment value is
added to the header CS register value. The result, along with the
header IP value, is used to give the module control.
-- cut here --
I'd have just given the location in the book, but I assume that not
everyoneants to pay the ghastly amount that IBM charges for that
tech manual. Anyway, that's what the book has to say about EXE files.
Good luck with whatever you're making, and happy hacking.
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
Jim Frost * The Madd Hacker | UUCP: ..!harvard!bu-cs!bucsb!madd
H H | ARPA: madd@bucsb.bu.edu
H-C-C-OH <- heehee +---------+----------------------------------
H H | "We are strangers in a world we never made"
The above was an excerpt of UUCP Netnews, from E-mag, (713)561-0400.