BELLCORE Information by The Mad Phone-man
|
|
--------------------------------------------------------------------
|
|
|
|
So, You've broken into the big phone box on the wall, and are looking at
|
|
a bunch of tags with numbers and letters on them. Which one is the modem
|
|
line? Which one is the 1-800 WATTS line? Which one is the Alarm Line?
|
|
Bell has a specific set of codes that enable you to identify what you're
|
|
looking at. These are the same codes the installer gets from the wire
|
|
center to enable him to setup the line, test it, and make sure it matches
|
|
the customers order. Here are some extracts from the Bellcore book.
|
|
|
|
First lets take a Hypothetical Line number I'm familiar with:
|
|
64FDDV 123456
|
|
-------------------------------------------------------------
|
|
The serial number format:
|
|
|
|
Prefix + service code + modifier + serial number +
|
|
digits: 1,2 3,4 5,6 7,8,9,10,11,12 continued
|
|
-------------------------------------------------------------------------
|
|
|
|
Suffix + CO assigning circut number + segmet
|
|
digits: 13,14,15 16,17,18,19 20,21,22
|
|
-------------------------------------------------------------------------
|
|
|
|
The Important shit is in the 3d thru 6th digit.
|
|
|
|
SERVICE CODES Intra or Inter LATA Block 1-26
|
|
-----------------
|
|
AA- Packet Analog Access line
|
|
AB- Packet switch trunk
|
|
AD- Attendant
|
|
AF- Commercial audio fulltime
|
|
AI- Automatic Identified outward dialing
|
|
AL- Alternate services
|
|
AM- Packet, off-network access line
|
|
AN- Announcement service
|
|
AO- International/overseas audio (full time)
|
|
AP- Commercial audio (part time)
|
|
AT- International/overseas audio (part time)
|
|
AU- Autoscript
|
|
BA- Protective alarm (CD)
|
|
BL- Bell & Lights
|
|
BS- Siren control
|
|
CA- SSN Access
|
|
CB- OCC Audio facilitys
|
|
CC- OCC Digital facility-medium speed
|
|
CE- SSN Station Line
|
|
CF- OCC Special facility
|
|
CG- OCC Telegraph facility
|
|
CH- OCC Digital facility High-speed
|
|
CI- Concentrator Identifier trunk
|
|
CJ- OCC Control facility
|
|
CK- OCC Overseas connecting facility wide-band
|
|
CL- Centrex CO line
|
|
CM- OCC Video facility
|
|
CN- SSN Network trunk
|
|
CO- OCC Overseas connecting facility
|
|
CP- Concentrator identifier signaling link
|
|
CR- OCC Backup facility
|
|
CS- Channel service
|
|
CT- SSN Tie trunk
|
|
CV- OCC Voice grade facility
|
|
CW- OCC Wire pair facility
|
|
CZ- OCC Access facility
|
|
DA- Digital data off-net extention
|
|
DB- HSSDS 1.5 mb/s access line
|
|
DF- HSSDS 1.5 mb/s hub to hub
|
|
DG- HSSDS 1.5 mb/s hub to earth station
|
|
DH- Digital service
|
|
DI- Direct-in dial
|
|
DJ- Digit trunk
|
|
DK- Data Link
|
|
DL- Dictation line
|
|
DO- Direct-out dial
|
|
DP- Digital data-2 4 kb/s
|
|
DQ- Digital data-4 8 kb/s
|
|
DR- Digital data-9.6 kb/s
|
|
DW- Digital data-56 kb/s
|
|
DY- Digital service (under 1 mb/s)
|
|
EA- Switched access
|
|
EB- ENFIA II end office trunk
|
|
EC- ENFIA II tandem trunk
|
|
EE- Combined access
|
|
EF- Entrance facility-voice grade
|
|
EG- Type #2 Telegraph
|
|
EL- Emergency reporting line
|
|
EM- Emergency reporting center trunk
|
|
EN- Exchange network acess facility
|
|
EP- Entrance facility-program grade
|
|
EQ- Equipment only-(network only) assignment
|
|
ES- Extension service-voice grade
|
|
ET- Entrance facility-telegraph grade
|
|
EU- Extension service-telegraph grade
|
|
EV- Enhanced Emergency reporting trunk
|
|
EW- Off network MTS/WATS equivalent service
|
|
FD- Private line-data
|
|
FG- Group-supergroup spectrum
|
|
FR- Fire dispatch
|
|
FT- Foreign exchange trunk
|
|
FW- Wideband channel
|
|
FV- Voice grade facility
|
|
FX- Foreign exchange
|
|
HP- Non-DDS Digital data 2.4 kb/s
|
|
HQ- Non-DDS Digital data 4.8 kb/s
|
|
HR- Non-DDS Digital data 9.6 kb/s
|
|
HW- Non-DDS Digital data 56 kb/s
|
|
IT- Inter-tandem tie trunk
|
|
LA- Local area data channel
|
|
LL- Long distance terminal line
|
|
LS- Local service
|
|
LT- Long distance terminal trunk
|
|
MA- Cellular access trunk 2-way
|
|
MT- Wired music
|
|
NA- CSACC Link (EPSCS)
|
|
NC- CNCC link (EPSCS)
|
|
ND- Network data line
|
|
OI- Off premises intercommunication station line
|
|
ON- Off network access line
|
|
OP- Off premises extension
|
|
OS- Off premises PBX station line
|
|
PA- Protective alarm (AC)
|
|
PC- Switched digital-access line
|
|
PG- paging
|
|
PL- Private line-voice
|
|
PM- Protective monitoring
|
|
PR- Protective relaying-voice grade
|
|
PS- MSC constructed spare facility
|
|
PV- Protective relaying-telegraph grade
|
|
PW- Protective relaying-signal grade
|
|
PX- PBX station line
|
|
PZ- MSC constructed circut
|
|
QU- Packet asyncronous access line
|
|
QS- Packet synchronous access line
|
|
RA- Remote attendant
|
|
RT- Radio landline
|
|
SA- satellite trunk
|
|
SG- control/remote metering signal grade
|
|
SL- secretarial line
|
|
SM- sampling
|
|
SN- Special access termination
|
|
SQ- equipment only-customer premises
|
|
SS- dataphone select-a-station
|
|
TA- Tandem tie-trunk
|
|
TC- Control/remote metering-telegraph grade
|
|
TF- Telephoto/facsimile
|
|
TK- Local PBX trunk
|
|
TL- Non-tandem tie trunk
|
|
TR- turret or automatic call distributor (ACD) trunk
|
|
TT- Teletypewriter channel
|
|
TU- Turret or automatic call distributor (ACD) line
|
|
TX- Dedicated facility
|
|
VF- Commercial television (full time)
|
|
VH- Commercial television (part time)
|
|
VM- Control/remote metering-voice grade
|
|
VO- International overseas television
|
|
VR- Non-commercial Television (7003,7004)
|
|
WC- Special 800 surface trunk
|
|
WD- Special WATS trunk (OUT)
|
|
WI- 800 surface trunk
|
|
WO- WATS line (OUT)
|
|
WS- WATS trunk (OUT)
|
|
WX- 800 service line
|
|
WY- WATS trunk (2-way)
|
|
WZ- WATS line (2-way)
|
|
ZA- Alarm circuts
|
|
ZC- Call and talk circuts
|
|
ZE- Emergency patching circuts
|
|
ZF- Order circuts, facility
|
|
ZM- Measurement and recording circuts
|
|
ZP- Test circut, Plant service center
|
|
ZQ- Quality and management circuts
|
|
ZS- Switching, control and transfer circuts
|
|
ZT- Test circuts, central office
|
|
ZV- Order circuts, service
|
|
|
|
SERVICE CODES FOR LATA ACCESS
|
|
---------------------------------------------------
|
|
HC- High capacity 1.544 mb/ps
|
|
HD- High capacity 3.152 mb/ps
|
|
HE- High capacity 6.312 mb/ps
|
|
HF- High capacity 6.312
|
|
HG- High capacity 274.176 mb/s
|
|
HS- High capacity subrate
|
|
LB- Voice-non switched line
|
|
LC- Voice-switched line
|
|
LD- Voice Switched trunk
|
|
LE- Voice and tone-radio landline
|
|
LF- Data low-speed
|
|
LG- Basic data
|
|
LH- Voice and data-PSN access trunk
|
|
LJ- Voice and data SSN access
|
|
LK- Voice and data-SSN-intermachine trunk
|
|
LN- Data extension, voice grade data facility
|
|
LP- Telephoto/facsimile
|
|
LQ- Voice grade customized
|
|
LR- Protection relay-voice grade
|
|
LZ- dedicated facility
|
|
MQ- Metalic customized
|
|
NQ- Telegraph customized
|
|
NT- Protection alarm-metalic
|
|
NU- Protection alarm
|
|
NV- Protective relaying/telegraph grade
|
|
NW- Telegraph grade facility-75 baud
|
|
NY- Telegraph grade facility- 150 baud
|
|
PE- Program audio, 200-3500 hz
|
|
PF- Program audio, 100-5000 hz
|
|
PJ- Program audio, 50-8000 hz
|
|
PK- Program audio, 50-15000 hz
|
|
PQ- Program grade customized
|
|
SB- Switched access-standard
|
|
SD- Switched access-improved
|
|
SE- Special access WATS-access-std
|
|
SF- Special access- WATS access line improved
|
|
SJ- Limited switched access line
|
|
TQ- Television grade customized
|
|
TV- TV Channel one way 15khz audio
|
|
TW- TV Channel one way 5khz audio
|
|
WB- Wideband digital, 19.2 kb/s
|
|
WE- Wideband digital, 50 kb/s
|
|
WF- Wideband digital, 230.4 kb/s
|
|
WH- Wideband digital, 56 kb/s
|
|
WJ- Wideband analog, 60-108 khz
|
|
WL- Wideband analog 312-552 khz
|
|
WN- Wideband analog 10hz-20 khz
|
|
WP- Wideband analog, 29-44 khz
|
|
WR- Wideband analog 564-3064 khz
|
|
XA- Dedicated digital, 2.4 kb/s
|
|
XB- Dedicated digital, 4.8 kb/s
|
|
XG- Dedicated digital, 9.6 kb/s
|
|
XH- Dedecated digital 56. kb/s
|
|
|
|
|
|
|
|
Now the last two positions of real importance, 5 & 6 translate thusly:
|
|
|
|
Modifier Character Position 5
|
|
------------------------------
|
|
|
|
INTRASTATE INTERSTATE
|
|
-------------------------------------
|
|
A B Alternate data & non data
|
|
-------------------------------------
|
|
C Customer controlled Service
|
|
-------------------------------------
|
|
D E Data
|
|
-------------------------------------
|
|
N L Non-data operation
|
|
-------------------------------------
|
|
P Only offered under intra Restructured
|
|
private line (RPL) tariff (Payphones)
|
|
-------------------------------------
|
|
S T Simultanious data & non-data
|
|
-------------------------------------
|
|
F Interexchange Carriers is less than 50%
|
|
-------------------------------------
|
|
G Interstate carrier is more than 50% usage
|
|
===============================================================================
|
|
|
|
MODIFIER CHARACTER POSITION 6
|
|
--------------------------------------------------------------
|
|
|
|
TYPE OF SERVICE Intra LATA
|
|
--------------------------------------
|
|
ALL EXCEPT US GOVT US GOVERNMT
|
|
--------------------------------------
|
|
T M Circut is BOC customer to BOC customer
|
|
all facilitys are TELCO provided
|
|
--------------------------------------
|
|
C P Circut is BOC/BOC and part of facilitys
|
|
or equipment is telco provided
|
|
--------------------------------------
|
|
A J Circut is BOC/BOC all electricaly
|
|
connected equip is customer provided
|
|
--------------------------------------
|
|
L F Circut terminates at Interexchange
|
|
carrier customers location
|
|
--------------------------------------
|
|
Z Offical company service
|
|
--------------------------------------
|
|
Interlata
|
|
S S Circut terminates at Interexchange
|
|
carriers point of term (POT)
|
|
--------------------------------------
|
|
V V Circut terminates at an interface of a
|
|
Radio common carrier (RCC)
|
|
--------------------------------------
|
|
Z Official company service
|
|
--------------------------------------
|
|
|
|
Corridor
|
|
Y X Corridor circut
|
|
--------------------------------------
|
|
International
|
|
K H Circut has at least 2 terminations in
|
|
different countries
|
|
--------------------------------------
|
|
interexchange carrier
|
|
Y X Transport circut between Interexchange
|
|
carrier terminals.
|
|
----------------------------------------
|
|
|
|
|
|
|
|
|
|
So 64FDDV would be a private line data circut terminating at a radio common
|
|
carrier. Other examples can be decoded likewise.
|
|
|
|
|
|
|
|
Enjoy this information as much as I've had finding it, and bringing it to you!
|
|
|
|
-= The Mad Phone-man =-
|
|
|
|
Leeched from The Knight Society (716)745-3231
|
|