! Bell Telephone Info !
|
||
\-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-/
|
||
|
||
|
||
******************************************************************************
|
||
|
||
BRIDGING HEADS, RESIDENTIAL AND BUSINESS MULTILINE DISTRIBUTION BOXES, LINE
|
||
AND TRUNK SPLITTERS, AND OTHER BELL SYSTEM WIRE TERMINATIONS.
|
||
|
||
- HOW TO USE, AND/OR ABUSE THEM -
|
||
|
||
(INCLUDING A TUTORIAL ON BASIC TELEPHONE EAVESDROPPING TECHNIQUES.)
|
||
|
||
******************************************************************************
|
||
|
||
WRITTEN BY : PHUCKED
|
||
AGENT 07/29/84
|
||
04
|
||
|
||
REVISED FOR LOD! 10/84
|
||
CURRENTLY REVISION II
|
||
|
||
****************************************************************************
|
||
|
||
IN THIS ARTICLE, I WILL FIRST BESCRIBE THE TERMINATION, WIRING, AND
|
||
TERMINAL HARDWARE MOST COMMONLY USED IN THE BELL SYSTEM, AND I WILL INCLUDE
|
||
A SECTION ON METHODS OF USING THEM.
|
||
|
||
*****************************************************************************
|
||
|
||
-------------
|
||
LOCAL NETWORK
|
||
-------------
|
||
|
||
THE LOCAL TELEPHONE NETWORK BETWEEN THE CENTRAL OFFICE/EXCHANGE AND
|
||
THE TELEPHONE SUBSCRIBERS CAN BE BREIFLY DESCRIBED AS FOLLOWS:
|
||
FROM THE CENTRAL OFFICE (OR LOCAL EXCHANGE) OF A CERTAIN PREFIX(ES),
|
||
UNDERGROUND AREA FEEDER TRUNKS GO TO EACH AREA THAT HAS THAT PREFIX. (USUALLY
|
||
MORE THAN ONE PREFIX PER AREA) AT EVERY FEW STREETS OR TRACT AREAS, THE
|
||
UNDERGROUND CABLES SURFACE. THEY THEN GO TO THE SECONDARY TERMINATION, (THE
|
||
AERIAL TELEPHONE FEEDER CABLE) (OR BACK UNDERGROUND, DEPENDING ON THE AREA) AND
|
||
THEN TO THE SUBSRIBERS HOUSE (OR IN THE CASE OF AN APARTMENT BUILDING OR
|
||
MUTLILINE BUSINESS, TO A SPLITTER OR DISTRIBUTION BOX/PANEL).
|
||
|
||
NOW THAT WE HAVE THE BASICS, I'LL TRY AND GO IN-DEPTH ON THE SUBJECT.
|
||
|
||
------------------
|
||
UNDERGROUND CABLES
|
||
------------------
|
||
|
||
THESE ARE SOMETIMES INTEROFFICE TRUNKS, BUT USUALLY IN A RESIDENTIAL AREA
|
||
THEY ARE FEEDER GROUPS THAT GO OTO BRIDGING HEADS OR DISTRIBUTION CASES. THE
|
||
CABLES ARE ABOUT 2-3 INCHES THICK (VARIES), AND ARE EITHER IN A METAL OR
|
||
PVC-TYPE PIPE (OR SIMILAR). RARELY (MAYBE NOT IN SOME REMOTE RURAL AREAS) ARE
|
||
THE CABLES JUST 'ALONE' IN THE GROUND. INSTEAD, THEY ARE USUALLY IN AN
|
||
UNDERGROUND CEMENT TUNNEL (RESEMBLES A SMALL SEWER OR STORMDRAIN). THE MANHOLES
|
||
ARE >HEAVY< AND WILL SAY 'BELL SYSTEM' ON THEM. THEY CAN BE OPEN ED WITH A 1/2
|
||
INCH WIDE CROWBAR (HOOK SIDE) INSERTED IN THE TOP RECTANGULAR HOLE. IF YOU GET
|
||
IT OPEN, GO INSIDE!! THERE ARE LADDER RUNGS TO HELP YOU CLIMB DOWN. YOU WILL
|
||
SEE THE CABLE PIPES ON THE WALL, WITH THE BLUE AND WHITE STRIPED ONE BEING THE
|
||
INTEROFFICE TRUNK GRP (AT LEAST IN MY AREA). THE OTHERS ARE LOCAL LINES, AND
|
||
ARE USUALLY MARKED OR COLOR CODED. THERE IS ALMOST ALWAYS A POSTED COLOR CODE
|
||
CHART ON THE WALL, NOT TO MENTION TELCO MANUALS DESCRIBING THE CABLES AND
|
||
TERMINALS, SO I NEED NOT GET INTO DETAIL. AGAIN: >IF YOU CAN GET INTO A
|
||
BELL MANHOLE, DO IT!, IT WILL PAY OFF<. ALSO, THERE IS USUALLY SOME KIND OF
|
||
TEST EQUIPMENT, AND OFTEN BELL TEST SETS ARE LEFT IN THERE. SO GET YOUR
|
||
CROWBARS!
|
||
|
||
--------------
|
||
BRIDGING HEADS - (WE MS2'S)
|
||
--------------
|
||
|
||
THE INNOCENT-LOOKING GRAYISH-GREEN BOXES. WHEN IN GROUPS OF TWO OR THREE,
|
||
THEY ARE FOR SECONDAY/TERTIARY TERMINATION AND ACCESS POINTS (BRIDGED ACCESS).
|
||
THESE ARE THE WESTERN ELECTRIC SAI 55 OR 22/E TERMINAL CASES. THEY HOLD ON THE
|
||
ORDER OF 900-1200 CABLE PAIRS. THIS IS USUALLY THE SECOND TERM. POSITION ON THE
|
||
LOCAL LOOP (AFTER THE MTF FRAME AT THE CO/ OR THE UNDERGROUND 'FTP' POSITION).
|
||
THESE CAN BE EITHER TRUNK BRIDGES OR BRIDGING FOR RESIDENCES. THE AREA FEEDER
|
||
BRIDGING HEADS ARE USUALLY LARGER, AND THEY HAVE THE 'WESTERN ELECTRIC' LOGO AT
|
||
THE BOTTOM, WHEREAS THE NORMAL BRIDGING HEADS (WHICH MAY BE DIFFERENT IN SOME
|
||
AREAS DEPENDING ON THE COMPANY YOU ARE SERVED BY. GTE B.H'S LOOK SLIGHTLY
|
||
DIFFERENT. ALSO, DO NOT BE FOOLED BY SPRINKLER BOXES!) CAN BE FOUND IN JUST
|
||
ABOUT EVERY CITY.
|
||
TO OPEN A BRIDGING HEAD: IF IT IS LOCKED (AND YOU'RE FEELING DESTRUCTIVE),
|
||
PUT A HAMMER OR CROWBAR (THE SAME ONE YOU USED ON THE MANHOLE) IN THE SLOT
|
||
ABOVE THE TOP HINGE OF THE RIGHT DOOR. PULL HARD, AND THE DOOR WILL RIP OFF.
|
||
VERY EFFECTIVE!
|
||
IF IT ISN'T LOCKED (AS USUAL), TAKE A 7/16 INCH HEX SOCKET AND WITH IT, TURN
|
||
THE BOLT ABOUT 1/8 OF A TURN TO THE LEFT (YOU SHOULD HEAR A SPRING RELEASE
|
||
INSIDE). HOLDING THE BOLT, TURN THE HANDLE ALL THE WAY TO THE RIGHT AND PULL
|
||
OUT.
|
||
NOW INSIDE, FIRST CHECK FOR A TEST-SET (WHICH ARE OFTEN LEFT BY BELL
|
||
EMPLOYEES). THERE SHOULD BE A PANEL OF CABLE PAIRS + SCREW TERMINALS (TYPE
|
||
45/47IB REGULAR BINDERS) . PUSH THE PANEL BACK ABOUT AN INCH OR SO, AND ROTATE
|
||
THE TOP LATCH (ROUND WITH A FLAT SECTION) DOWNWARD. RELEASE THE PANEL AND IT
|
||
WILL FALL ALL THE WAY FORWARD. THERE IS USUALLY A LARGE AMOUNT OF WIRE AND
|
||
EXTRA TERMINALS. THE TEST-SETS ARE OFTEN HIDDEN HERE, SO DONT OVERLOOK IT (400
|
||
FOOT ROLLS OF #22 SOLID WIRE ARE OFTEN NEAR THE TOP IN THE BACK OF THE BOX.
|
||
'BORROW THEM'). ON THE RIGHT DOOR IS A METAL BOX OF INSULATORS, BINDERS, CLIPS,
|
||
ETC. TAKE A FEW (COMPLIMENTS OF BELL...). ON EACH DOOR IS A USEFUL ROUND METAL
|
||
DEVICE. (SAYS 'INSERT GENTLY' OR 'CLAMP GENTLY - DO NOT OVERTIGHTEN' ETC..) ON
|
||
THE FRONT OF THE DISC, YOU SHOULD FIND TWO TERMINALS. THESE ARE FOR YOUR TEST
|
||
SET. (IF YOU DONT HAVE ONE, DONT DEPAIR -I'LL SHOW YOU WAYS TO MAKE BASIC TEST
|
||
SETS LATER IN THIS ARTICLE). HOOKING THE RING (-) WIRE TO THE 'R' TERMINAL; AND
|
||
THE TIP (+) WIRE TO THE OTHER. (BY THE WAY, AN EASY WAY TO DETERMINE THE
|
||
CORRECT POLARITY IS WITH A 1.5V LED. TAP IT TO THE TERM. PAIR, IF IT DOESNT
|
||
LIGHT, SWITCH THE POLES UNTIL IT DOES. WHEN IT LIGHTS, FIND THE LONGER OF THE
|
||
TWO LED POLES. THIS ONE WILL BE ON THE TIP WIRE (+)) BEHIND THE DISC IS A
|
||
COILED UP CORD. THIS SHOULD HAVE A SPECIALIZED CONNECTOR. ITS VERY USEFUL,
|
||
BECAUSE YOU DONT HAVE TO KEEP CONNECTING AND DISCONNECTING THE FONE (TEST SET)
|
||
ITSELF, AND THE CLIP IS DESIGNED TO AID IN LOCATING THE PAIR AND ASSURING THE
|
||
CORRECT POLARITY.
|
||
ON THE TERMINAL BOARD, THERE SHOULD BE ABOUT 20 PAIRS (RED/WHITE) PER ROW
|
||
PER SIDE. HOOK THE CLIP TO ANY TERMINAL PAIR, AND YOU'RE SET! DIAL OUT IF YOU
|
||
WANT, OR JUST LISTEN (IF SOMEONE'S ON THE LINE). LATER, I'LL SHOW YOU A WAY TO
|
||
SET UP A TRUE 'TAP' THAT YOU CAN SETUP, AND WILL LET THE PERSON DIAL OUT ON HIS
|
||
LINE AND RECEIVE CALLS AS NORMAL, AND YOU CAN LISTEN IN THE WHOLE TIME. MORE
|
||
ABOUT THIS LATER...
|
||
ON MAJOR PREFIX-AREA BRIDGING HEADS ('SAI' FOR AREA C.O. FEEDER CABLE) YOU
|
||
CAN SEE TEMPORARY 'LOCAL LOOPS', WHICH ARE TWO CABLE PAIRS (CABLE PAIR =RING +
|
||
TIP, A FONE LINE) THAT ARE DIRECTLY CONNECTED TO EACH OTHER ON THE TERMINAL
|
||
BOARD. THESE 'CHEAP LOOPS' AS THEY ARE CALLED, DO NOT WORK NEARLY AS WELL AS
|
||
THE EXISTING ONES SET UP IN THE SWITCHING HARDWARE AT THE EXCHANGE OFFICE. (TRY
|
||
SCANNING YOUR PREFIXES' 00XX OR 99XX #'S. THE TONE SIDES WILL ANNOUNCE
|
||
THEMSELVES WITH THE 1000 HZ LOOP TONE, AND THE HANG SIDE WILL GIVE NO RESPONSE.
|
||
THE FIRST PERSON SHOULD DIAL THE 'HANG' SIDE, AND THE OTHER PERSON DIAL THE,
|
||
TONE SIDE, AND THE TONE SHOULD STOP IF YOU HAVE GOT THE RIGHT LOOP). THE LOOPS
|
||
ARE USED IN FRAME TERMINATION AND IN SONIC/600 OHM TERM. TESTING AND
|
||
LINE/CABLE/FEEDER LOCATION.
|
||
IF YOU WANT TO FIND THE NUMBER OF THE LINE THAT YOU'RE ON, YOU CAN EITHER
|
||
TRY TO DECIPHER THE 'BRIDGING LOG' (OR WHATEVER), WHICH IS ON THE LEFT DOOR. IF
|
||
THAT DOESNT WORK, YOU CAN USE THE FOLLWING:
|
||
|
||
---
|
||
ANI # (AUTOMATIC NUMBER INDENTICATION)
|
||
---
|
||
THIS IS A TELCO TEST NUMBER THAT REPORTS TO YOU THE NUMBER THAT YOU'RE
|
||
CALLING FROM (IT'S THE SAME, CHOPPY 'BELL BITCH' VOICE THAT YOU GET WHEN YOU
|
||
REACH A DISCONNECTED #) (PIP OR ONE OF THE 11X SERIES ANNOUNCE MENT FRAME
|
||
MACHINES.)
|
||
|
||
FOR THE 213 NPA - DIAL 1223
|
||
213 NPA - (GTE AREAS) DIAL 114
|
||
408 NPA - DIAL 760
|
||
914 NPA - DIAL 990
|
||
|
||
THESE ARE EXTREMELY USEFUL WHEN MESSING WITH ANY KIND OF LINE TERMINALS,
|
||
FEEDER BOXES, ETC.
|
||
|
||
WHEN FINISHED, BE SURE TO CUT OFF THE CONNECTOR AND TAKE IT WITH YOU (THEY
|
||
ARE VERY HANDY), AND CLOSE/LATCH THE BOX TO AVOID SUSPICION.
|
||
|
||
|
||
"CANS" - AERIAL-MOUNTED (TELEPHONE POLE TERMINAL) BRANCH FEEDER CABLE
|
||
SPLITTER.
|
||
----
|
||
|
||
BASICALLY, TWO TYPES:
|
||
|
||
1> MS3A SERVICE AREA INTERFACE. (LARGE, RECTANGULAR SILVER BOX AT THE END OF
|
||
EACH STREET.)
|
||
|
||
2> SERIES 600 LOADING COIL, INCLUDES THE MSX AERIAL DROP SPLITTER. (BLACK,
|
||
ROUND OR RECTANGULAR THING AT EVERY TELEPHONE POLE.)
|
||
|
||
|
||
TYPE 1 - THIS IS THE CASE THAT TAKES THE UNDERGROUND CABLE FROM THE BRIDGER
|
||
AND RUNS IT TO THE AERIAL BRANCH FEEDER CABLE (THE LOWEST, LARGEST WIRE ON THE
|
||
TELEPHONE POLE). THE BOX IS ALWAYS ON THE POLE NEAREST THE BRIGING HEAD, WHERE
|
||
THE LINE COMES UP. LOOK FOR THE 'CALL BEFORE YOU DIG - UNDERGROUND CABLE'
|
||
STICKERS..
|
||
THE CASE BOX IS HINGED, SO IF YOU WANT TO CLIMB THE POLE, YOU CAN OPEN IT
|
||
WITH NO PROBLEMS. THESE USUALLY HAVE 2 ROWS OF TERMINAL SETS. (TOTAL APPROX.
|
||
200-600 PAIRS, DEPENDING ON THE AREA.) THESE ARE ALL THE CABLE PAIRS FOR YOUR
|
||
STREET. (ITS SIMILAR TO A MINIATURE BRIDGING HEAD). USE/ABUSE IT IN THE SAME
|
||
MANNER AS WE DID BEFORE. (NOTE: ALL THE ACTIVE LINES CARRY FROM 15 TO 48 VDC,
|
||
AND EVEN 90VAC (WHEN RINGING), SO BE CAREFUL - IT'S NOT GOING TO HURT YOU,
|
||
BUT IT CAN SURPRISE YOU (AND IF YOU'RE HANGING BY ONE HAND FROM A TEL. POLE, IT
|
||
>CAN< BE HARMFUL!))
|
||
OH, BY THE WAY, IF YOU USE ANI ON EVERY PAIR AND YOU FIND ONE THAT ISNT IN
|
||
USE ON YOUR STREET, YOU CAN HOOK IT UP FOR YOURSELF (ALMOST). ALSO, YOU HAVE TO
|
||
BE ABLE TO IMPERSONATE A TELCO TECHNICIAN AND REPORT THE NUMBER AS 'NEW ACTIVE'
|
||
(GIVING A FAKE NAME AND FAKE REPORT, ETC) I DONT RECOMMEND THIS AND IT PROBABLY
|
||
WONT (ALMOST POSITIVELY WONT) WORK, BUT THIS IS BASICALLY WHAT TELCO LINEMEN
|
||
DO).*
|
||
|
||
* THE USE OF THE 'TEST BOARD' (A 7D# FOR LINEMEN TESTS, OFTEN FOUND
|
||
NXX-0003 OR NXX-0004) IS BEYOND THE SCOPE OF THIS ARTICLE, BUT WILL BE COVERED
|
||
IN A FUTURE ARTICLE.
|
||
|
||
|
||
TYPE 2 - THIS IS THE SPLITTER BOX FOR THE AERIAL DROP WIRES FOR THE GROUP OF
|
||
HOUSES AROUND THE POLE. (USUALLY 4 OR 5 HOUSES). USE IT LIKE I MENTIONED
|
||
BEFORE. THE TERMINALS (20 OR SO) WILL BE IN 2 HORIZONTAL ROWS OF SETS. THE
|
||
EXTRA WIRES THAT ARE JUST 'HANGING THERE' ARE PROVISIONS FOR EXTRA LINES TO
|
||
RESIDENCES (1 EXTRA LINE PER HOUSE, THATS WHY THE INSANE CHARGE FOR LINE #3).
|
||
IF ITS THE BOX FOR YOUR HOUSE ALSO, HAVE FUN AND SWAP LINES WITH YOUR NEIGHBOR!
|
||
'PIGGYBACK' THEM OR USE A CHEESEBOX FOR A LOOP-AROUND, ETC. AGAIN, I DONT
|
||
RECOMMEND THIS, AND ITS DIFFICULT TO DO IT CORRECTLY. (ALTHOUGH USEFUL)
|