textfiles/phreak/CELLULAR/cellqst1.txt
2021-04-15 13:31:59 -05:00

53 lines
1.8 KiB
Plaintext
Raw Blame History

This file contains invisible Unicode characters

This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

CELLQUEST
NOTES: This is a single NAM unit.
The ESN prefix is 174 decimal & AE hex.
Shintom: 213-328-7200
NAM PROGRAMING:
1. Turn power on.
2. If not locked press FUNC 5 to lock.
3. Enter FUNC # 6 2 6 # FUNC. (626 SPELLS NAM)
4. The SEND key stores and increments each step.
5. You can jump to any entry by pressing END STEP# SEND.
6. At any time press END FUNC END to complete and exit programing.
7. The first two (unnumbered) steps below are not strictly programing
data, and can not be altered, but are shown for clarity.
PROGRAMING DATA:
STEP# #OF DIGITS/RANGE DESCRIPTION
CAN NOT BE CHANGED MODEL NUMBER & SOFTWARE VERSION
CAN NOT BE CHANGED ESN IN HEX
01 3 DIGITS AREA CODE
02 7 DIGITS PHONE NUMBER
03 00000 - 32767 SYSTEM ID
04 2 DIGITS ACCESS OVERLOAD CLASS
05 2 DIGITS GROUP ID (10 IN USA)
06 0 OR 1 LOCAL USE MARK
07 0 OR 1 MIN MARK
08 3 DIGITS LOCK CODE
09 0 OR 1 AUTO LOCK
10 3 DIGITS CALL RESTRICTION CODE (DEFAULTS TO LOCK CODE)
11 2 DIGITS CALL COUNTER RESET CODE (DEFAULTS TO FIRST TWO
DIGITS OF LOCK CODE)
12 0 OR 1 HANDS FREE
13 0 OR 1 HORN ALERT
14 0 TO 3 HORN ALERT TURN OFF DELAY (0 = 2 hrs, 1 = 4 hrs,
2 = 8 hrs, 3 = no turn off)
15 2 DIGITS TOTAL AIRTIME RESET CODE (DEFAULTS TO FIRST TWO
DIGITS OF LOCK CODE)
LOCK: F5, UNLOCK: 3 DIGIT CODE
SYSTEM SELECT: F7 = A ONLY, F8 = B ONLY (F7 OR F8 AGAIN WILL TOGGLE BACK TO
PREF/NON PREF)