BC140
|
|
|
|
|
|
One can convert this scanner from a 10 channel machine to 16 channels.
|
|
All one need do is rempve a diode.
|
|
turn off the power and unplug the power source and remove whip antenna.
|
|
Turn the scanner over and remove 4 screws.
|
|
Carefully seperate the cabinet halves, carefully as the top and
|
|
bottom are wired together.
|
|
locate corner of the board where the connectors for the front panel
|
|
are. See the 30 pin IC that says "Uniden". near this IC is a diode
|
|
with insulating tubing on its leads. One end of this diode is
|
|
connected to the topside of the board, and the other goes over the
|
|
edge of the board and is connected to the underside of the board.
|
|
Clip a lead or remove this diode.
|
|
You should have 16 channels now. Program them as you would the others.
|
|
(from 7/90 Monitoring Times, page 94)
|
|
|
|
|