AST RESEARCH, INC. TECHNICAL BULLETIN #0790 12-01-92
|
|
|
|
=============================================================================
|
|
|
|
|
|
BRAVO 4/33 LC AND IRWIN TAPE BACKUP UNIT
|
|
|
|
|
|
PROBLEM: Bravo 4/33 LC fails to recognize an Irwin A250EP Parallel Port
|
|
Tape Backup Unit. The EZ-Tape software that is provided with
|
|
the unit is unable to detect the tape drive connected to the
|
|
parallel port. This generates the error message "No tape
|
|
drive found."
|
|
|
|
CAUSE: The EZ-Tape software has several delay loops that are executed
|
|
too quickly on the Bravo 4/33 LC.
|
|
|
|
AFFECTED
|
|
SYSTEMS: All Bravo 4/33 LC systems.
|
|
|
|
SOLUTION: By patching the software and increasing the delay loops, the
|
|
EZ-Tape software can run properly on the Bravo 4/33 systems.
|
|
These delays can be added by manipulating an environment
|
|
string as follows:
|
|
|
|
SET PPCFDC=O:12,I:18
|
|
|
|
This string represents the environment for the Parallel Port
|
|
Controller Floppy Disk Controller (PPCFDC) to have an Output
|
|
delay factor of 12 (O:12) and an Input delay factor of 18
|
|
(I:18). These values were found to provide the best results
|
|
for the software to function properly. This environment
|
|
string can be typed at a DOS prompt before executing the EZ-
|
|
Tape software or by adding this line to the AUTOEXEC.BAT file.
|
|
|
|
This string will not decrease the functionality of the
|
|
software or system. The delay factors are only providing the
|
|
normal delay that would be done on systems that the software
|
|
was originally designed for.
|
|
|