AST RESEARCH, INC. TECHNICAL BULLETIN #0722 11-01-91
|
|
|
|
=============================================================================
|
|
|
|
|
|
ADVANCED FASTRAM
|
|
|
|
|
|
PROBLEM: Several customers have reported being unable to use the
|
|
Advanced FastRam board. The failure has been isolated to a
|
|
Improperly programmed smart switch device on the FastRam card
|
|
(IC U65 107000-642).
|
|
|
|
SYMPTOM: The Advanced FastRam is not being seen by the FastRam
|
|
software. The machine boots, but the I/O and starting address
|
|
is not recognized by the Configuration Utility software
|
|
(910314-301 revision A).
|
|
|
|
AFFECTED
|
|
SYSTEMS: Advanced FastRam card with the following part number:
|
|
|
|
202253-001 or 500565-001
|
|
|
|
SOLUTION: Any customers reporting this problem should contact their
|
|
local AST Service Center to have the defective IC,
|
|
(107000-642B) replaced.
|