AST RESEARCH, INC. TECHNICAL BULLETIN #0666 02-13-91
|
|
|
|
=============================================================================
|
|
|
|
|
|
NOVELL COMPSURF WITH ESDI DRIVES
|
|
|
|
|
|
Problems may occur when running Novell's Compsurf Utility with AST's OEM
|
|
version of the WD1007 ESDI controller (AST part number 240018-001) and the
|
|
Maxtor 4380 320 MB hard drive (AST part number 230055-320). Examples of some
|
|
errors are as follows:
|
|
|
|
- Abend: Disk Channel 0 could not reset controller
|
|
|
|
- Unable to access Sector 14
|
|
|
|
- Unable to read bad block table
|
|
|
|
To resolve the above problems, you must do the following:
|
|
|
|
- Do a low-level format using the manufacturer's utility software (i.e.,
|
|
HDFORMAT.EXE for an AST drive).
|
|
|
|
- Run Novell utility ESDIDISK.EXE. (Do not attempt more than three
|
|
passes.)
|
|
|
|
NOTE: The Novell utility ESDIDISK.EXE is available on Novell's Bulletin
|
|
Board (NETWIRE) and is listed as ESDIDR.ZIP in Library 6, Forum A.
|
|
This utility will:
|
|
|
|
- Check track zero.
|
|
|
|
- Scan the hard drive surface.
|
|
|
|
- Put the COMPSURF "stamp" on the drive.
|
|
|
|
- Create a bad block table that Novell can use.
|