AST RESEARCH, INC. TECHNICAL BULLETIN #TB-0348 12/16/88
|
||
|
||
TURBOLASER/PS ROTARY SWITCH CONNECTOR TO PCB
|
||
|
||
|
||
PROBLEM:
|
||
|
||
Some early models of the TurboLaser/PS printers contain
|
||
Rotary Switch Assemblies that have a four position connector
|
||
housing. This switch matches the four position post header of
|
||
J-3 located on the early model PostScript PCB's. Later model
|
||
printers contain Rotary Switch Assemblies that have a five
|
||
position connector that match the five position post header at
|
||
J-3 on the newer model PostScript controller boards.
|
||
|
||
This has created a problem of incompatibility between the
|
||
PostScript printers: IE: new model printers with the five
|
||
position Rotary Switch connectors, will not be able to
|
||
utilize older model PostScript PCB,s, and older model printers
|
||
will not be able to utilize the newer model PostScript PCB,s.
|
||
|
||
HISTORY OF CHANGES
|
||
|
||
The Rotary Switch Assy, AST Part Number 220261-001 has the
|
||
five position connector.
|
||
|
||
The Rotary Switch Assy, AST Part Number 220261-002 has the
|
||
four position connector.
|
||
|
||
The TurboLaser PostScript PCB AST Part Number 202219-001
|
||
(artwork REV X3 and below) has the four position post header
|
||
at J-3.
|
||
|
||
The TurboLaser PostScript PCB AST Part Number 202219-001
|
||
(artwork REV X4 and above) has the five position post header
|
||
at J-3. Note: Rev A is later than any X type revision.
|
||
|
||
SOLUTION
|
||
|
||
If maintenance of the TurboLaser/PS printer requires
|
||
replacement of either the Rotary Switch Assembly or the
|
||
PostScript PCB, the technician must be aware of the
|
||
differences mentioned above and insure that correct parts are
|
||
available to make the repair.
|
||
|
||
|
||
|
||
|