AST RESEARCH TECHNICAL BULLETIN TB-0278A 08/28/87
|
||
|
||
|
||
RAMPAGE 286
|
||
|
||
|
||
AST customers have reported some difficulties when using the
|
||
Rampage 286 product. The symptoms occur when the Rampage
|
||
286 is being used to fill in conventional memory (below
|
||
640K).
|
||
|
||
The actual symptoms are that data is being corrupted during
|
||
a DMA transfer. This most commonly happens during a copy or
|
||
back-up type operation.
|
||
|
||
Rampage 286 boards that may exhibit this tendency can be
|
||
identified by part number "202154-301" revision level "X1".
|
||
These numbers are located on the circuit side of the board,
|
||
along the edge of the board on the end opposite the mounting
|
||
bracket.
|
||
|
||
Observe the circuit side of the board and verify if there is
|
||
a jumper wire connected to lifted pin U111-19 (74LS245) to
|
||
pin U76-9 (PLS153). This jumper should correct the problem.
|
||
|
||
If the jumper is not installed and the above problem exists,
|
||
contact AST Product Support for further instructions.
|
||
|