21 lines
768 B
Plaintext
21 lines
768 B
Plaintext
AST RESEARCH TECHNICAL BULLETIN TB-0164 4-24-86
|
||
|
||
|
||
AST-5251/11 CABLE TERMINATION
|
||
|
||
|
||
If the PC is the last unit on the twinax cable, the user must
|
||
terminate the cable in one of two ways:
|
||
|
||
1. Install the terminator jumpers on the TAB in the manner
|
||
described in the AST-5251/11 User's Manual, part number
|
||
000196-001 D, Section 3.1.5, on pages 3-9 and 3-10.
|
||
|
||
2. Or, remove the terminator jumpers and install a "termin-
|
||
ator plug" on the end of the cable, as described in the
|
||
AST-5251/11 User's Manual, part number 000196-001 D,
|
||
section 4.3, on pages 4-5 and 4-6.*
|
||
|
||
|
||
* "Terminator plugs" are not supplied by AST.
|
||
|