ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»
|
|
º º
|
|
º SatisFAXtion Modem/400: Solutions to Common Problems º
|
|
º º
|
|
ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ
|
|
|
|
CONFLICTS WITH 8514A COMPATIBLE VIDEO BOARDS
|
|
|
|
The IBM 8514a and compatible video boards will conflict with any modem
|
|
or faxmodem you configure as COM4. This is because 8514a and
|
|
compatible video boards use the I/O address 2E8 which is the I/O
|
|
address used by COM4.
|
|
|
|
If you use an 8514a or compatible video board, DO NOT set your modem
|
|
or faxmodem to COM4. Neither the video board nor the modem will
|
|
operate reliably.
|
|
|
|
This also applies to video boards based on the S3 chipset.
|
|
|
|
S3-BASED VIDEO BOARDS
|
|
|
|
Video boards based on the S3 86C911 controller will use the I/O
|
|
address 2E8 (but won't use IRQ 3). This means you can't address your
|
|
modem as COM4.
|
|
|
|
The S3 controller has several features derived from the IBM 8514/a
|
|
adapter. Along with these features comes inherent issues with 8-bit
|
|
devices.
|
|
The 86C911 is a 16-bit device that uses x2E8h, x6E8, xAE8, xEE8h to
|
|
access its enhanced more register; all 16 bits are decoded. Since the
|
|
AT bus decodes only the lower 10 bits of the I/O address, conflicts
|
|
will occur between the 86C911 and other devices using the same
|
|
addresses.
|
|
|
|
WINFAX PRO LOCKS UP WHEN VIEWING FAILED RECEIVE
|
|
|
|
SatisFAXtion/200, /400, and Classic:
|
|
When running CASMGR 1.40, WinFax Pro may lock up when you view a
|
|
failed receive event in the WinFax log. Delrina's fix for this problem
|
|
is now available on CompuServe and the Delrina BBS in an archive file
|
|
called CAS.EXE. The archive file contains a program named a README
|
|
file and the program CASFIX.EXE. The README file instructs you to add
|
|
the CASFIX command immediately following the CASMGR command in your
|
|
AUTOEXEC.BAT file.
|
|
|
|
CONFIGURING YOUR SYSTEM'S MEMORY
|
|
|
|
For information on configuring your system's memory for use with
|
|
SatisFAXtion products, order FaxBACK document 4149.
|
|
|
|
HOW TO CREATE LOGO FILES
|
|
|
|
For detailed instructions on how to create logo files using various
|
|
graphics programs, order FaxBACK document 4006.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ
|
|
|
|
October 29, 1992 Intel FaxBACK # 4044 Page 1
|
|
|
|
ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»
|
|
º º
|
|
º SatisFAXtion Modem/400: Solutions to Common Problems º
|
|
º º
|
|
ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ (continued) ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ
|
|
|
|
THE INPUT FILE CONTAINS HP GL/2 COMMANDS...
|
|
|
|
...that are not supported by the emulator. Try setting your
|
|
application to use an HP LaserJet II printer driver.
|
|
|
|
While FAXPOP does support the HPPCL (Hewlett-Packard Printer Control
|
|
Language) up to and including verison 5, FAXPOP doesn't support the
|
|
HPGL (Hewlett-Packard Graphics Language). Use a printer driver that
|
|
doesn't incorporate HPGL commands.
|
|
|
|
For WordPerceft 5.1, use either an HP LJIII driver dated 3-92 or
|
|
earlier or just use an HP LJII driver.
|
|
|
|
CAN'T PRINT ON POSTSCRIPT PRINTER
|
|
|
|
Version 1.40 of the FAX.EXE program only prints on PostScript printers
|
|
when you select Print from the View Screen. If you print from any
|
|
other menu, the computer appears to send the data and the printer
|
|
appears to accept it. However, the page never actually prints.
|
|
|
|
Intel has corrected the problem and an updated MA.UTL file is
|
|
available on FaxBACK. The MA.UTL file is still version 1.40, but the
|
|
date on the file is 6-92 or later.
|
|
|
|
SatisFAXtion Modem/200 users, order document 0028.
|
|
SatisFAXtion Modem/400 users, order document 0029.
|
|
|
|
MODEM WON'T AUTOANSWER WHEN SLS ENABLED
|
|
|
|
If the SatisFAXtion board is set for "Shares phone line, mostly fax
|
|
calls", "shares phone line, mostly voice calls", or "Shares phoneline,
|
|
has a distinctive ring", modem callers MUST include the characters @#
|
|
at the end of their dialing string. The "@" command tells the calling
|
|
modem to wait for a period of silence (30 seconds by default). The "#"
|
|
character tells the answering SatisFAXtion board the call is from a
|
|
modem.
|
|
|
|
Otherwise, if no CNG tone is detected, the SatisFAXtion board will
|
|
assume the call is a voice call and ring the downline phone. If users
|
|
truly need the board to arbitrate between fax and modem calls without
|
|
user intervention, then they must set the SLS setting for "has its own
|
|
phone line".
|
|
|
|
NO DIALTONE ON DOWN-LINE PHONE
|
|
|
|
SatisFAXtion/200, SatisFAXtion/400
|
|
If you get a clicking sound or no dialtone on your down-line phone
|
|
after selecting one of the "Shares phone line" answering options, try
|
|
selecting the answering option "Has own phone line". If you get a
|
|
dialtone then, check the version number on your DOWNLOAD file. If you
|
|
have a DOWNLOAD.200 version earlier than 2.04 or a DOWNLOAD.400
|
|
version earlier than 3.01, call FaxBACK and order the latest DOWNLOAD
|
|
file for your board.
|
|
|
|
|
|
|
|
ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ
|
|
|
|
October 29, 1992 Intel FaxBACK # 4044 Page 2
|
|
|
|
ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»
|
|
º º
|
|
º SatisFAXtion Modem/400: Solutions to Common Problems º
|
|
º º
|
|
ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ (continued) ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ
|
|
|
|
Order 0028 for the Latest DOWNLOAD.200 (SatisFAXtion/200 only)
|
|
Order 0029 for the latest DOWNLOAD.400 (SatisFAXtion/400 only)
|
|
|
|
TROUBLESHOOTING SEND/RECEIVE PROBLEMS
|
|
|
|
If you're having trouble sending or receiving, here are some thing you
|
|
can try:
|
|
|
|
þ Always load a disk cache program BEFORE loading CASMGR.
|
|
|
|
þ Always load network software BEFORE loading CASMGR and FAXPOP.
|
|
|
|
þ Do not load anti-virus software in TSR mode.
|
|
|
|
þ If you use the STACKER program to increace your disk storage
|
|
space, always load the STACKER drivers BEFORE loading SATISFAX.SYS
|
|
in your CONFIG.SYS file.
|
|
|
|
þ If you use QEMM 6.0, disable the STEALTH feature. Later versions
|
|
may or may not have this STEALTH mode problem fixed.
|
|
|
|
V.17 14.4KBPS RECEIVE STATUS REPORT
|
|
|
|
For the latest status on the SatisFAXtion Modem/400 high-speed receive
|
|
problem, order FaxBACK document 9983.
|
|
|
|
TELENET
|
|
|
|
Several customers have reported problems using this service. These
|
|
range from locking the system to not being able to connect.
|
|
|
|
SatisFAXtion/400:
|
|
SatisFAXtion Modem/400 users should use DOWNLOAD.400 version 3.02 or
|
|
higher when calling Telenet.
|
|
|
|
SatisFAXtion Classic:
|
|
SatisFAXtion users need software version 1.20 to connect to Telenet.
|
|
Also please note that you must type @ then press ENTER to get the
|
|
Telenet prompt.
|
|
|
|
CONFIGURING YOUR COMMUNICATIONS SOFTWARE
|
|
|
|
If your communications software doesn't list your SatisFAXtion
|
|
faxmodem but does list an Intel modem, choose the equivalent Intel
|
|
modem:
|
|
|
|
Intel Modem SatisFAXtion Faxmodem
|
|
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
|
|
14.4EX Modem/400, Modem/400e
|
|
9600EX Modem/400, Modem/400e (Set port speed to 57600)
|
|
2400 MNP/2400EX MNP Modem/200
|
|
2400B/2400EX Modem/100
|
|
|
|
|
|
|
|
|
|
ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ
|
|
|
|
October 29, 1992 Intel FaxBACK # 4044 Page 3
|
|
|
|
ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»
|
|
º º
|
|
º SatisFAXtion Modem/400: Solutions to Common Problems º
|
|
º º
|
|
ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ (continued) ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ
|
|
|
|
If your communications software doesn't list any Intel modems, order
|
|
the FaxBACK Communications software Index (document 4351). This index
|
|
will tell you how to find instructions for configuring many popular
|
|
communications programs.
|
|
|
|
MY SOFTWARE DOESN'T LIST THE INTEL MODEM
|
|
|
|
If your communications program doesn't list your Intel modem in the
|
|
setup screen, try selecting a Hayes compatible configuration. If the
|
|
problem persists, change the "Initialization String" to match your
|
|
modem type:
|
|
|
|
Intel Modem Initialization String
|
|
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
|
|
Intel V.42 modems (1,2) : AT&F\N0\Q0\J1\V0"H0-J0
|
|
Intel 2400B MNP modems (3): AT&F\N0\Q0\J1\V0
|
|
Intel non-MNP modems (4) : AT&F&C1&D2
|
|
|
|
CARBON COPY FOR WINDOWS
|
|
|
|
SatisFAxtion/400:
|
|
You need DOWNLOAD.400 version 3.02 or higher to use Carbon for Windows
|
|
with a SatisFAXtion Modem/400. Earlier versions didn't implement the
|
|
Ring Indicator signal which Carbon Copy uses to detect incoming calls.
|
|
|
|
I/O AND IRQ CONFLICTS
|
|
|
|
When two devices share the same I/O address or IRQ (interrupt), one or
|
|
the other (or both) devices may not work correctly. To eliminate the
|
|
potential for conflicts, make sure each device you add to your
|
|
computer occupies a unique I/O address and IRQ.
|
|
|
|
Standard COM (serial) Port Address/IRQ Settings
|
|
|
|
I/O
|
|
Port Address IRQ
|
|
---- ------- ---
|
|
COM1 3F8 4
|
|
COM2 2F8 3
|
|
COM3 3E8 4
|
|
COM4 2E8 3
|
|
|
|
Intel faxmodems and modems come with a program called TESTCOM.EXE that
|
|
can tell you what I/O address and IRQs are in use. Change to the disk
|
|
or directory containing TESTCOM.EXE and enter this command: TESTCOM
|
|
/S
|
|
|
|
If TESTCOM reports that only COM1 is active, set the modem to COM2.
|
|
If TESTCOM reports both COM1 and COM2 active, disable the COM2 port in
|
|
your computer (if possible) so that you can set the modem to COM2.
|
|
See the user's guide for your computer to find out how to disable a
|
|
COM port.
|
|
|
|
|
|
|
|
|
|
ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ
|
|
|
|
October 29, 1992 Intel FaxBACK # 4044 Page 4
|
|
|
|
ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»
|
|
º º
|
|
º SatisFAXtion Modem/400: Solutions to Common Problems º
|
|
º º
|
|
ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ (continued) ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ
|
|
|
|
If you're using both COM1 and COM2 or can't disable COM2, you may be
|
|
able to use COM3 or COM4 depending on the devices attached to COM1 and
|
|
COM2. A mouse and a modem will not successfully share an IRQ. A
|
|
printer and a modem sometimes can share an IRQ.
|
|
|
|
The Intel SatisFAXtion faxmodems, Intel internal 2400 baud modems, and
|
|
the Connection CoProcessor Modem Option allow two additional
|
|
configurations:
|
|
|
|
COM3 3E8 IRQ 5 (works in 286/386/486-based (AT) computers)
|
|
COM4 2E8 IRQ 2 (works in 8088/8086-based (PC/XT) computers)
|
|
|
|
NOTE: Before configuring your modem for COM3/IRQ 5 or COM4/IRQ 2,
|
|
make sure your communications software supports these ports.
|
|
|
|
NOTE: Never use IRQ 5 in 8088/8086-based computers because IRQ 5
|
|
is used by your hard drive. Never use IRQ 2 in 286/386/486-
|
|
based computers because IRQ 2 is used to "cascade" the two
|
|
interrupt controllers.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ
|
|
|
|
October 29, 1992 Intel FaxBACK # 4044 Page 5
|