Inpho on Automatic Line Testers From the Telescum Manuals..
|
||
Typed Together by RiPMaX/LIBERTY!!
|
||
|
||
DOC NO : [1/4]
|
||
|
||
AUTOMATIC LINE TESTERS - A.P.R.
|
||
|
||
GENERAL
|
||
-------
|
||
|
||
The A.P.R. is installed in exchanges to provide automatic testing facilities
|
||
for telephones and line conditioners on exchange services. After clearing a
|
||
fault it is necessary to test the complete telephone service including the
|
||
insulation resistance of the line to earth and between the pair, the bell and
|
||
dial operation. Access to the A.P.R. testing equipment is obtained by dialing
|
||
the special number allotted to the particular exchange. It is only necessary
|
||
to gain access to the A.P.R. tester once. All subsequent tests may be made by
|
||
dialing the code digit for that test. Tests listed below may be preformed in
|
||
any order or independantly of each other without the need to release the
|
||
tester.
|
||
|
||
OBTAIN ACCESS TO A.P.R. TESTER
|
||
------------------------------
|
||
|
||
Dial access code number for the particular exchange.
|
||
|
||
* If tester is free ring tone will be heard immediately.
|
||
* If no tone is heard then WAIT for busy tone, hang up and try again.
|
||
* If while waiting the tester becomes free, ring tone will be heard.
|
||
|
||
Hang up and wait for the telephone bell to ring (about 4 seconds).
|
||
Lift reciever on ring back. If A.P.R. tone (900hz) is heard, the circuit is
|
||
ready to proceed with testing.
|
||
The A.P.R. is released when the handset is replaced after a test.
|
||
|
||
INSULATION TEST (A TO EARTH)
|
||
----------------------------
|
||
|
||
Obtain access to A.P.R. tester.
|
||
Dial 5 , Listen for Busy Tone.
|
||
Hang up and wait for telephone bell to ring.
|
||
Lift receiver on ring back.
|
||
listen for tone :
|
||
|
||
* Dial tone = Line OK (I * R over 1 Mê [ohm]).
|
||
* NU tone = Line faulty (I * R 0.5Mê to 1Mê).
|
||
* Ring tone = Line faulty (I * R under 0.5Mê).
|
||
|
||
INSULATION TEST (B TO EARTH)
|
||
----------------------------
|
||
|
||
Dial 6 and listen for busy tone.
|
||
Continue as for Insulation test A to Earth.
|
||
|
||
INSULATION RESISTANCE (A TO B)
|
||
------------------------------
|
||
|
||
Dial 7 and Listen for busy tone.
|
||
Continue as for Insulation test A to Earth.
|
||
|
||
LINE LOOP RESISTANCE
|
||
--------------------
|
||
|
||
Dial 8.
|
||
Listen to tones :
|
||
|
||
* NU tone = line OK.
|
||
* Dial tone = Loop resistance too high.
|
||
* Ring tone = Loop resistance 200ê or less.
|
||
|
||
DIAL TEST (SPEED)
|
||
-----------------
|
||
|
||
Dial 1 then 0.
|
||
Listen to tone :
|
||
|
||
* NU tone = Dial speed OK.
|
||
* Dial tone = Dial fast (Replace).
|
||
* Ring tone = Dial slow (Replace).
|
||
|
||
DIAL TEST (RATIO)
|
||
-----------------
|
||
|
||
* NU tone = Dial Ratio OK.
|
||
* Dial tone = Ratio high (Replace).
|
||
* Ring tone = ratio low (Replace).
|
||
|
||
BELL OPERATION (FULL VOLTAGE)
|
||
-----------------------------
|
||
|
||
Dial 3 and listen for busy tone.
|
||
Hang up and ringing commences in 4 to 5 seconds.
|
||
Lift receiver to trip ring.
|
||
|
||
BELL OPERATION (HALF VOLTAGE)
|
||
-----------------------------
|
||
|
||
Dial 4 and listen for busy tone.
|
||
Continue as for Full voltage test.
|
||
|
||
TESTING CONTROL OF A.P.R.
|
||
-------------------------
|
||
|
||
Dial 0 and listen for A.P.R. tone (900Hz), which indicates that the testing
|
||
equipment is functioning correctly. This test may be done at any time after
|
||
access to A.P.R. tester.
|
||
|
||
Hang up to release testing equipment.
|
||
|
||
*******************************************************************************
|
||