The following tips were retrieved from the Micropolis BBS as tech tips
|
|
which their support team uses in resolving customer issues.
|
|
|
|
1. Ultrastor 12F when installing NETWARE 2.15A
|
|
Low-level format using the physical parameters(no
|
|
translation) to use the full capacity of Micropolis drives
|
|
that exceed 1024 cylinders. Install Advanced Netware 2.15A
|
|
using the "Default" configuration.
|
|
|
|
2. Ultrastor 12F in EISA machines.
|
|
To configure an Ultrastor 12F in an EISA bus you must use the
|
|
file USC0120.CFG located on the ultrastor diskettes.
|
|
|
|
3. WD1007x
|
|
Say "NO" to "enable alternate sectors?" during low-level the
|
|
format. The use of alternate sectors will disable WD1007x 63
|
|
sector translation mode. *NOTE* alternate sectors may be
|
|
enabled when no translation will be required.
|
|
|
|
4. WD1007v-SE1/SE2
|
|
Models 1568-15 and 1664-7 must have the W2 jumper removed from
|
|
the drive. Removing the W2 jumpers changes the drive geometry
|
|
from 54 to 53 spt. The WD1007V does NOT support 54 spt.
|
|
|
|
5. SCSI
|
|
The drive and host adapter must have different SCSI ID's.
|
|
Conflicting SCSI ID's will cause a variety of problems.
|
|
|
|
6. ESDI Drive Splitting
|
|
Enabling drive splitting with ESDI controllers will limit the
|
|
system to one physical EDSI drive. The computer CMOS must be
|
|
set for two physical drives set to type (Type 1)
|
|
|
|
7. ESDI
|
|
When using ESDI controllers and drives, you must be sure that
|
|
the controller has a transfer rate equal to or higher than the
|
|
drive. Eg.. WD1007A is a 10 Megahertz controller, with a 1664-
|
|
7 which is a 15 Megahertz drive. This is an incompatible mix.
|
|
|
|
8. UltraStor and Netware
|
|
UltraStor 12/f is certified for Netware 2.2 and Netware 386
|
|
v3.11 with the Rev 009 bios on the controller.
|
|
|
|
9. In-2000 Synchronous negotiation
|
|
Set SW-8 to "ON" position to force the IN-2000 to initiate
|
|
synchronous negotiation.
|
|
|
|
10. HS Code
|
|
HS code supports 512 bytes per sector only. This applies to
|
|
firmware P/N 800574-XX-X.
|
|
|
|
11. RS6000
|
|
HSP4 (800574-03-0) will issue an Illegal request in
|
|
CDB(05/24h) when formatted with AIX "Service and Diagnostics
|
|
Module". ASOC must be used in an IBM RS6000 machines. HS code
|
|
doesn't support a command issued by the RS6000.
|
|
|
|
12. Future Domain 1680 Host Adapter
|
|
Disk Manager will not initialize a drive over 1.2 gigabytes.
|
|
You must use have a bios revision of 2.0 and higher for the
|
|
Future Domain 1680. You must use Disk Maestro or Debug to
|
|
format the drives.
|
|
|
|
13. SCO UNIX
|
|
The boot partition must reside under 1024 cylinders or you will
|
|
have erratic behavior of the OS.
|
|
|
|
14. Ultra 12f-24 with Two drives
|
|
When a 1518-15 is attached to the 12f and additional drive will
|
|
be will be added , the bios on the Ultrastor should be Rev.
|
|
-010.
|
|
|
|
15. DPT / MYLEX WITH 1598 AND 1528
|
|
The firmware on the drives must be DD24_1 to work with DPT and
|
|
Mylex Host Adapters.
|
|
|
|
16. PS2 Model 95 and 1528
|
|
Configure automatically with the reference diskette and the
|
|
utility will return '????' as the 2nd drive.
|
|
After configuration, the drive will respond normally.
|
|
|
|
17. Always and UNIX / XENIX
|
|
If a customer has problems creating the N1 boot diskette, the
|
|
customer can call Always and they will create the N1 diskette
|
|
for the customer.
|
|
|
|
18. WESTERN DIGITAL 7000FASST
|
|
The WD7000FASST host adapter does not support parity.
|
|
Micropolis drives must have parity disabled by placing a jumper
|
|
on W9 on the 1674 /1684 or w4 on 1578/1588/1598/1528. On the
|
|
models 1548/1908/1624 drives to disable parity jumper in 13-14
|
|
in the J2 connector. (Download the drive spec sheet from the
|
|
files section of the BBS).
|
|
|
|
19. ULTRASTOR(ALL CONTROLLERS)
|
|
Ultrasor ESDI controllers will not co-reside with any other
|
|
manufacturers controller card under Netware.
|
|
|