A Practical Guide to RS-232 Interfacing
|
||
|
||
Lawrence E. Hughes
|
||
|
||
Mycroft Labs, Inc.
|
||
P.O. Box 6045
|
||
Tallahassee, FL 32301
|
||
|
||
The following information is intended to collect together in
|
||
one place, and explain in relatively simple terms, enough of the
|
||
details of the RS-232 standard to allow a technician to construct
|
||
and/or debug interfaces between any two "RS-232 Compatible"
|
||
devices. A more detailed coverage of the subject may be found in
|
||
the book "Technical Aspects of Data Communication" by John E.
|
||
McNamara (1977, Digital Press).
|
||
|
||
This guide is necessary due to the casual way that vendors
|
||
implement "RS-232" interfaces, sometimes omitting required
|
||
signals, requiring optional ones, or worse, implementing signals
|
||
incorrectly. Due to this, and a lack of readily available
|
||
information about the real EIA standard, there is often
|
||
considerable confusion involved in trying to interface two RS-232
|
||
devices.
|
||
|
||
BACKGROUND
|
||
|
||
RS-232-C is the most recent version of the EIA (Electronics
|
||
Industry Association) standard for low speed serial data
|
||
communication. It defines a number of parameters concerning
|
||
voltage levels, loading characteristics and timing relationships.
|
||
The actual connectors which are almost universally used (DB-25P
|
||
and DB-25S, sometimes called "EIA connectors") are recommended,
|
||
but not mandatory. Typical practice requires mounting the female
|
||
(DB-25S) connector on the chassis of communication equipment, and
|
||
male (DB-25P) connectors on the cable connecting two such
|
||
devices.
|
||
|
||
There are two main classes of RS-232 devices, namely DTE (Data
|
||
Terminal Equipment), such as terminals, and DCE (Data
|
||
Communication Equipment), such as modems. Typically, one only
|
||
interfaces a DTE to a DCE, as opposed to one DTE to another DTE,
|
||
or one DCE to another DCE, although there are ways to do the
|
||
later two by building non-standard cables. Rarely if ever are
|
||
more than two devices involved in a given interface (multidrop is
|
||
not supported). A serial port on a computer may be implemented as
|
||
either DTE or DCE, depending on what type of device it is
|
||
intended to support.
|
||
|
||
RS-232 is intended for relatively short (50 feet or less),
|
||
relatively low speed (19,200 bits per second or less) serial (as
|
||
opposed to parallel) communications. Both asynchronous and
|
||
synchronous serial encoding are supported. As 'digital' signals
|
||
(switched D.C. voltage, such as square waves) are used, as
|
||
opposed to 'analog' signals (continuously varying voltage, such
|
||
as sine waves) a very wide bandwidth channel (such as direct
|
||
wire) is required. A limited bandwidth channel (such as a phone
|
||
circuit) would cause severe and unacceptable distortion and
|
||
consequent loss of information.
|
||
|
||
RS-232 will support simplex, half-duplex, or full-duplex type
|
||
channels. In a simplex channel, data will only ever be travelling
|
||
in one direction, e.g. from DCE to DTE. An example might be a
|
||
'Receive Only' printer. In a half-duplex channel, data may travel
|
||
in either direction, but at any given time data will only be
|
||
travelling in one direction, and the line must be 'turned around'
|
||
before data can travel in the other direction. An example might
|
||
be a Bell 201 style modem. In a full-duplex channel, data may
|
||
travel in both directions simultaneously. An example might be a
|
||
Bell 103 style modem. Certain of the RS-232 'hand-shaking' lines
|
||
are used to resolve problems associated with these modes, such as
|
||
which direction data may travel at any given instant.
|
||
|
||
If one of the devices involved in an RS-232 interface is a
|
||
real modem (especially a half-duplex modem), the 'hand-shaking'
|
||
lines must be supported, and the timing relationships between
|
||
them are quite important. These lines are typically much easier
|
||
to deal with if no modems are involved. In certain cases, these
|
||
lines may be used to allow one device (which is receiving data at
|
||
a higher rate than it is capable of processing indefinitely) to
|
||
cause the other device to pause while the first one 'catches up'.
|
||
This use of the hand-shaking lines was not really intended by the
|
||
designers of the RS-232 standard, but it is a useful by-product
|
||
of the way such interfaces are typically implemented.
|
||
|
||
Much of the RS-232 standard is concerned with support of
|
||
'modems'. These are devices which can convert a serial digital
|
||
data signal into an analog signal compatible with a narrow
|
||
bandwidth (e.g. 3 kHz) channel such as a switched telephone
|
||
circuit, and back into serial digital data on the other end. The
|
||
first process is called 'MOdulation', and the second process is
|
||
called 'DEModulation', hence the term 'MODEM'. The actual process
|
||
used (at data rates of up to 1200 bits per second) is FSK
|
||
(Frequency Shift Keying), in which a constant frequency sine wave
|
||
(called the 'carrier') is shifted to a slightly higher or
|
||
slightly lower frequency to represent a logic 0 or logic 1,
|
||
respectively. In a half duplex modem, the entire available
|
||
bandwidth is used for one direction. In a full duplex modem, the
|
||
available bandwidth is divided into two sub-bands, hence there is
|
||
both an 'originate carrier' (e.g. for data from the terminal to
|
||
the computer), and an 'answer carrier' (e.g. for data from the
|
||
computer to the terminal). The actual frequencies (in Hertz) used
|
||
on the Bell 103A full duplex modem are:
|
||
|
||
signal state Originate Answer
|
||
|
||
logic 0 SPACE 1180 1850
|
||
carrier 1080 1750
|
||
logic 1 MARK 980 1650
|
||
|
||
.pa
|
||
THE STANDARD CIRCUITS AND THEIR DEFINITIONS
|
||
|
||
For the purposes of the RS-232 standard, a 'circuit' is
|
||
defined to be a continuous wire from one device to the other.
|
||
There are 25 circuits in the full specification, less than half
|
||
of which are at all likely to be found in a given interface. In
|
||
the simplest case, a full-duplex interface may be implemented
|
||
with as few as 3 circuits. There is a certain amount of confusion
|
||
associated with the names of these circuits, partly because there
|
||
are three different naming conventions (common name, EIA circuit
|
||
name, and CCITT circuit name). The table below lists all three
|
||
names, along with the circuit number (which is also the connector
|
||
pin with which that circuit is normally associated on both ends).
|
||
Note that the signal names are from the viewpoint of the DTE
|
||
(e.g. Transmit Data is data being sent by the DTE, but received
|
||
by the DCE).
|
||
|
||
PIN NAME EIA CCITT DTE DCE FUNCTION
|
||
|
||
1 CG AA 101 --- Chassis Ground
|
||
2 TD BA 103 --> Transmit Data
|
||
3 RD BB 104 <-- Receive Data
|
||
4 RTS CA 105 --> Request To Send
|
||
5 CTS CB 106 <-- Clear To Send
|
||
6 DSR CC 107 <-- Data Set Ready
|
||
7 SG AB 102 --- Signal Ground
|
||
8 DCD CF 109 <-- Data Carrier Detect
|
||
9* <-- Pos. Test Voltage
|
||
10* <-- Neg. Test Voltage
|
||
11 (usually not used)
|
||
12+ SCDC SCF 122 <-- Sec. Data Car. Detect
|
||
13+ SCTS SCB 121 <-- Sec. Clear To Send
|
||
14+ STD SBA 118 --> Sec. Transmit Data
|
||
15# TC DB 114 <-- Transmit Clock
|
||
16+ SRD SBB 119 <-- Sec. Receive Data
|
||
17# RC DD 115 <-- Receive Clock
|
||
18 (not usally used)
|
||
19+ SRTS SCA 120 --> Sec. Request To Send
|
||
20 DTR CD 108.2 --> Data Terminal Ready
|
||
21* SQ CG 110 <-- Signal Quality
|
||
22 RI CE 125 <-- Ring Indicator
|
||
23* CH 111 --> Data Rate Selector
|
||
CI 112 <-- Data Rate Selector
|
||
24* XTC DA 113 --> Ext. Transmit Clock
|
||
25* --> Busy
|
||
|
||
In the above, the character following the pin number means:
|
||
|
||
* rarely used
|
||
+ used only if secondary channel implemented
|
||
# used only on synchronous interfaces
|
||
|
||
also, the direction of the arrow indicates which end (DTE or DCE)
|
||
originates each signal, except for the ground lines (---). For
|
||
example, circuit 2 (TD) is originated by the DTE, and received by
|
||
the DCE. Certain of the above circuits (11, 14, 16, and 18) are
|
||
used only by (or in a different way by) Bell 208A modems.
|
||
|
||
A secondary channel is sometimes used to provide a very slow
|
||
(5 to 10 bits per second) path for return information (such as
|
||
ACK or NAK characters) on a primarily half duplex channel. If the
|
||
modem used suppports this feature, it is possible for the
|
||
receiver to accept or reject a message without having to 'turn
|
||
the line around', a process that usally takes 100 to 200
|
||
milliseconds.
|
||
|
||
On the above circuits, all voltages are with respect to the
|
||
Signal Ground (SG) line. The following conventions are used:
|
||
|
||
Voltage Signal Logic Control
|
||
+3 to +25 SPACE 0 On
|
||
-3 to -25 MARK 1 Off
|
||
|
||
Note that the voltage values are inverted from the logic values
|
||
(e.g. the more positive logic value corresponds to the more
|
||
negative voltage). Note also that a logic 0 corresponds to the
|
||
signal name being 'true' (e.g. if the DTR line is at logic 0,
|
||
that is, in the +3 to +25 voltage range, then the Data Terminal
|
||
IS Ready).
|
||
|
||
ELECTRICAL CHARACTERISTICS OF EACH CIRCUIT
|
||
|
||
The following criteria apply to the electrical characteristics
|
||
of each of the above lines:
|
||
|
||
1) The magnitude of an open circuit voltage shall not exceed 25V.
|
||
|
||
2) The driver shall be able to sustain a short to any other wire
|
||
in the cable without damage to itself or to the other equipment,
|
||
and the short circuit current shall not exceed 0.5 ampere.
|
||
|
||
3) Signals shall be considered in the MARK (logic 1) state when
|
||
the voltage is more negative than -3V with respect to the Signal
|
||
Ground. Signals shall be considered in the SPACE (logic 0) state
|
||
when the voltage is more positive that 3V with respect to the
|
||
Signal Ground. The range between -3V and 3V is defined as the
|
||
transition region, within which the signal state is not defined.
|
||
|
||
4) The load impedance shall have a DC resistance of less than
|
||
7000 ohms when measured with an applied voltage of from 3V to 25V
|
||
but more than 3000 ohms when measured with a voltage of less than
|
||
25V.
|
||
|
||
5) When the terminator load resistance meets the requirements of
|
||
Rule 4 above, and the terminator open circuit voltage is 0V, the
|
||
magnitude of the potential of that circuit with respect to Signal
|
||
Ground will be in the 5V to 15V range.
|
||
|
||
6) The driver shall assert a voltage between -5V and -15V
|
||
relative to the signal ground to represent a MARK signal
|
||
condition. The driver shall assert a voltage between 5V and 15V
|
||
relative to the Signal Ground to represent a SPACE signal
|
||
condition. Note that this rule in conjunction with Rule 3 above
|
||
allows for 2V of noise margin. Note also that in practice, -12V
|
||
and 12V are typically used.
|
||
|
||
7) The driver shall change the output voltage at a rate not
|
||
exceeding 30 volts per microsecond, but the time required for the
|
||
signal to pass through the -3V to +3V transition region shall not
|
||
exceed 1 millisecond, or 4 percent of a bit time, whichever is
|
||
smaller.
|
||
|
||
8) The shunt capacitance of the terminator shall not exceed 2500
|
||
picofarads, including the capacitance of the cable. Note that
|
||
when using standard cable with 40 to 50 picofarads per foot
|
||
capacitance, this limits the cable length to no more than 50
|
||
feet. Lower capacitance cable allows longer runs.
|
||
|
||
9) The impedance of the driver circuit under power-off conditions
|
||
shall be greater than 300 ohms.
|
||
|
||
Note that two widely available integrated circuit chips (1488
|
||
and 1489) implement TTL to RS232 drivers (4 per chip), and RS232
|
||
receivers to TTL (also 4 per chip), in a manner consistent with
|
||
all of the above rules.
|
||
|
||
DEFINITION OF THE MOST COMMON CIRCUITS
|
||
|
||
1 CG Chassis Ground
|
||
|
||
This circuit (also called Frame Ground) is a mechanism to
|
||
insure that the chassis of the two devices are at the same
|
||
potential, to prevent electrical shock to the operator. Note
|
||
that this circuit is not used as the reference for any of
|
||
the other voltages. This circuit is optional. If it is used,
|
||
care should be taken to not set up ground loops.
|
||
|
||
2 TD Transmit Data
|
||
|
||
This circuit is the path whereby serial data is sent from
|
||
the DTE to the DCE. This circuit must be present if data is
|
||
to travel in that direction at any time.
|
||
|
||
3 RD Receive Data
|
||
|
||
This circuit is the path whereby serial data is sent from
|
||
the DCE to the DTE. This circuit must be present if data is
|
||
to travel in that direction at any time.
|
||
|
||
4 RTS Request To Send
|
||
|
||
This circuit is the signal that indicates that the DTE
|
||
wishes to send data to the DCE (note that no such line is
|
||
available for the opposite direction, hence the DTE must
|
||
always be ready to accept data). In normal operation, the
|
||
RTS line will be OFF (logic 1 / MARK). Once the DTE has
|
||
data to send, and has determined that the channel is not
|
||
busy, it will set RTS to ON (logic 0 / SPACE), and await an
|
||
ON condition on CTS from the DCE, at which time it may then
|
||
begin sending. Once the DTE is through sending, it will
|
||
reset RTS to OFF (logic 1 / MARK). On a full-duplex or
|
||
simplex channel, this signal may be set to ON once at
|
||
initialization and left in that state. Note that some DCEs
|
||
must have an incoming RTS in order to transmit (although
|
||
this is not strictly according to the standard). In this
|
||
case, this signal must either be brought across from the
|
||
DTE, or provided by a wraparound (e.g. from DSR) locally at
|
||
the DCE end of the cable.
|
||
|
||
5 CTS Clear To Send
|
||
|
||
This circuit is the signal that indicates that the DCE is
|
||
ready to accept data from the DTE. In normal operation, the
|
||
CTS line will be in the OFF state. When the DTE asserts RTS,
|
||
the DCE will do whatever is necessary to allow data to be
|
||
sent (e.g. a modem would raise carrier, and wait until it
|
||
stabilized). At this time, the DCE would set CTS to the ON
|
||
state, which would then allow the DTE to send data. When the
|
||
RTS from the DTE returns to the OFF state, the DCE releases
|
||
the channel (e.g. a modem would drop carrier), and then set
|
||
CTS back to the OFF state. Note that a typical DTE must have
|
||
an incoming CTS before it can transmit. This signal must
|
||
either be brought over from the DCE, or provided by a
|
||
wraparound (e.g. from DTR) locally at the DTE end of the
|
||
cable.
|
||
|
||
6 DSR Data Set Ready
|
||
|
||
This circuit is the signal that informs the DTE that the DCE
|
||
is alive and well. It is normally set to the ON state by the
|
||
DCE upon power-up and left there. Note that a typical DTE
|
||
must have an incoming DSR in order to function normally.
|
||
This line must either be brought over from the DCE, or
|
||
provided by a wraparound (e.g. from DTR) locally at the DTE
|
||
end of the cable. On the DCE end of the interface, this
|
||
signal is almost always present, and may be wrapped back
|
||
around (to DTR and/or RTS) to satisfy required signals whose
|
||
normal function is not required.
|
||
|
||
7 SG Signal Ground
|
||
|
||
This circuit is the ground to which all other voltages are
|
||
relative. It must be present in any RS-232 interface.
|
||
|
||
8 DCD Data Carrier Detect
|
||
|
||
This circuit is the signal whereby the DCE informs the DTE
|
||
that it has an incoming carrier. It may be used by the DTE
|
||
to determine if the channel is idle, so that the DTE can
|
||
request it with RTS. Note that some DTEs must have an
|
||
incoming DCD before they will operate. In this case, this
|
||
signal must either be brought over from the DCE, or provided
|
||
locally by a wraparound (e.g. from DTR) locally at the DTE
|
||
end of the cable.
|
||
|
||
15 TC Transmit Clock
|
||
|
||
This circuit provides the clock for the transmitter section
|
||
of a synchronous DTE. It may or may not be running at the
|
||
same rate as the receiver clock. This circuit must be
|
||
present on synchronous interfaces.
|
||
|
||
17 RC Receiver Clock
|
||
|
||
This circuit provides the clock for the receiver section of
|
||
a synchronous DTE. It may of may not be running at the same
|
||
rate as the transmitter clock. Note that both TC and RC are
|
||
sourced by the DCE. This circuit must be present on
|
||
synchronous interfaces.
|
||
|
||
20 DTR Data Terminal Ready
|
||
|
||
This circuit provides the signal that informs the DCE that
|
||
the DTE is alive and well. It is normally set to the ON
|
||
state by the DTE at power-up and left there. Note that a
|
||
typical DCE must have an incoming DTR before it will
|
||
function normally. This signal must either be brought over
|
||
from the DTE, or provided by a wraparound (e.g. from DSR)
|
||
locally at the DCE end of the cable. On the DTE side of the
|
||
interface, this signal is almost always present, and may be
|
||
wrapped back around to other circuits (e.g. DSR, CTS and/or
|
||
DCD) to satisfy required hand-shaking signals if their
|
||
normal function is not required.
|
||
|
||
Note that in an asynchronous channel, both ends provide their
|
||
own internal timing, which (as long as they are within 5% of each
|
||
other) is sufficient for them to agree when the bits occur within
|
||
a single character. In this case, no timing information need be
|
||
sent over the interface between the two devices. In a synchronous
|
||
channel, however, both ends must agree when the bits occur over
|
||
possibly thousands of characters. In this case, both devices must
|
||
use the same clocks. Note that the transmitter and receiver may
|
||
be running at different rates. Note also that BOTH clocks are
|
||
provided by the DCE. When one has a synchronous terminal tied
|
||
into a synchronous port on a computer via two synchronous modems,
|
||
for example, and the terminal is transmitting, the terminal's
|
||
modem supplies the Transmit Clock, which is brought directly out
|
||
to the terminal at its end, and encodes the clock with the data,
|
||
sends it to the computer's modem, which recovers the clock and
|
||
brings it out as the Receive Clock to the computer. When the
|
||
computer is transmitting, the same thing happens in the other
|
||
direction. Hence, whichever modem is transmitting must supply the
|
||
clock for that direction, but on each end, the DCE device
|
||
supplies both clocks to the DTE device.
|
||
|
||
All of the above applies to interfacing a DTE device to a DCE
|
||
device. In order to interface two DTE devices, it is usually
|
||
sufficient to provide a 'flipped' cable, in which the pairs (TD,
|
||
RD), (RTS,CTS) and (DTR,DSR) have been flipped. Hence, the TD of
|
||
one DTE is connected to the RD of the other DTE, and vica versa.
|
||
It may be necessary to wrap various of the hand-shaking lines
|
||
back around from the DTR on each end in order to have both ends
|
||
work. In a similar manner, two DCE devices can be interfaced to
|
||
each other.
|
||
|
||
An RS-232 'break-out box' is particularly useful in solving
|
||
interfacing problems. This is a device which is inserted between
|
||
the DTE and DCE. Firstly, it allows you to monitor the state of
|
||
the various hand-shaking lines (light on = signal ON / logic 0),
|
||
and watch the serial data flicker on TD and/or RD. Secondly, it
|
||
allows you to break the connection on one or more of the lines
|
||
(with dip-switches), and make any kind of cross-connections
|
||
and/or wraparounds (with jumper wires). Using this, it is fairly
|
||
easy to determine which line(s) are not functioning as required,
|
||
and quickly build a prototype of a cable that will serve to
|
||
interface the two devices. At this point, the break-out box can
|
||
be removed and a real cable built that performs the same
|
||
function. An example of this kind of device is the International
|
||
Data Sciences, Inc. Model 60 'Modem and Terminal Interface Pocket
|
||
Analyzer' (also called a 'bluebox'). Care should be taken with
|
||
this type of device to connect the correct end of it to the DTE
|
||
device, or the lights and switches do not correspond to the
|
||
actual signals.
|
||
|
||
|