272 lines
9.4 KiB
Plaintext
272 lines
9.4 KiB
Plaintext
|
||
FORVAL MODEMS
|
||
Super High-Speed,
|
||
Internal / External, Dial-up Modems
|
||
For IBM PC / Compatibles
|
||
|
||
Forval's full-duplex IM / SA series of dial-up modems are quality
|
||
engineered for super high-speeds. The IM14400 (Internal) at 14.4 kbps
|
||
and the SA14400 (External) at 14.4 kbps are versatile full duplex
|
||
V.32bis / V.42bis modems for personal computers with industry-standard
|
||
speeds of 14400 / 12000 / 9600 / 4800 / 2400 / 1200 / 300 bps.
|
||
|
||
These models offer data compression for throughput up to FOUR TIMES
|
||
FASTER than the base speed and advanced error correction for exceptional
|
||
accuracy.
|
||
|
||
The IM Series is designed to expand its capabilities as your needs
|
||
change. With the exclusive " FORVAL-LINK (tm) software, upgrades can be
|
||
made in a matter of minutes over the phone line.
|
||
|
||
With FORVAL, you have the MODEM-With-A-Future!
|
||
|
||
FEATURES:
|
||
|
||
-14.4 bps ( New V.32bis CCITT standard ) Fully compatible with all
|
||
other brand v.32bis modems.
|
||
-l9.2 bps Proprietary mode ( IM19200 / SA19200 models only. ) This code
|
||
will be changed to be fully compatible with the CCITT standard when
|
||
approved for 19.2 Kbps.
|
||
|
||
* Super high speeds - up to 57.6 Kbps with data compression
|
||
* All standard dial-up speeds- complies with both CCITT and Bell
|
||
standards. Compatible with all major modems.
|
||
* FORVAL LINK (tm) upgrades - download new features, speeds and
|
||
capabilities over the phone.
|
||
* FORVAL TURBO INTERFACE (tm) provides absolute data integrity between
|
||
your PC and the IM14400 at all speeds.
|
||
* Compatible with the Hayes (tm) "AT" command set and a wide range of
|
||
communications software.
|
||
* Built in self-test and diagnostics
|
||
* The SA14400 has an LCD display providing complete insight into modem
|
||
operations. Can be positioned horizontally or vertically.
|
||
* 5 year warranty ( one of the few manufacturers that offer this )
|
||
|
||
|
||
INFORMATION:
|
||
|
||
The IM14400 / SA14400 modems comply with the V.32bis standard for
|
||
data transmission, V.42 error correction and V.42.bis, the newest
|
||
data compression standard. By combining the latest industry standards
|
||
with intelligent engineering, the asynchronous IM14400 / SA14400
|
||
deliver data at an impressive base speed of 14,400 bps. And the
|
||
V.42bis provides a 4:1 data compression ratio with speeds exceeding
|
||
57.6Kbps-transmitting over six times faster than 9600 bps modems.
|
||
|
||
COMPATIBILITY:
|
||
|
||
When connecting with slower modems, the IM14400/SA14400 modems offer
|
||
excellent compatibility and high data performance over a broad range
|
||
of transmission speeds. Equipped with automatic step-down via CCITT
|
||
standards, the IM14400/SA14400 ensure data transference at the highest
|
||
levels of speed, compression and error correction possible.
|
||
|
||
For custom modem configurations, the IM14400/SA14400 feature user-
|
||
selectable options for setting speed rates, data compression levels
|
||
and error handling methods.
|
||
|
||
SOPHISTICATED ERROR CORRECTION AND HANDLING:
|
||
|
||
When exchanging critical data at accelerated speeds, accuracy is
|
||
imperative. With the IM14400/SA14400 modems, sophisticated error
|
||
correction and data handling capability, data integrity is preserved
|
||
under the worst line conditions. The built-in Turbo Interface on the
|
||
IM14400 provides absolute data integrity at all speeds along with
|
||
full flow control of remote modems. The SA14400 modem has the optional
|
||
Turbo Interface Card that can be purchased to provide the same reliability
|
||
as the Internal modem.
|
||
|
||
PRODUCT SPECIFICATIONS
|
||
IM14400/SA14400
|
||
|
||
SPEED/COMPATABIITY
|
||
DATA TRANSMISSION SPEED:
|
||
Base Speed: 14,400bps
|
||
Maximim Compressed: 115,200
|
||
Asynchronous
|
||
Transmission: DTE to Modem
|
||
|
||
COMPATABILITY SPEEDS
|
||
CCITT V.32bis 14,400/12000bps
|
||
CCITT V.32 9600/4800bps
|
||
CCITT V.22bis 2400/1200bps
|
||
Bell 212A 1200bps
|
||
Bell 103 300bps
|
||
|
||
COMMAND SET:
|
||
Hayes AT command set with MNP and V.42/V.42bis Extensions
|
||
|
||
THROUGHPUT CONTROL:
|
||
Automatic fallback via CCITT standards
|
||
|
||
TRANSMIT AND RECEIVE LEVELS:
|
||
Trasmit: - 10dBm
|
||
receive: - 6dBm to -45dBm
|
||
|
||
DATA FORMAT:
|
||
Asynchronous 7,8 bits: 1 or 2 stop bits
|
||
Parity: Even, odd, mark, space or none
|
||
Uses: AT/PC COM1, COM2, COM3 or COM4
|
||
DTE speed conversions
|
||
|
||
FLOW CONTROL:
|
||
XON/XOFF, RTS/CTS
|
||
|
||
DATA COMPRESION/ERROR CONTROL:
|
||
Error control
|
||
V.42(LAPM and MNP Class 2-4)
|
||
trellis Encoding with Viterbi decoding
|
||
FORVAL Turbo Interface
|
||
|
||
DATA COMPRESSION:
|
||
V.42bis: Compression up to 4:1
|
||
Throughput up to 57.6Kps
|
||
MNP Class 5: Compression up to 2:1
|
||
Throughput up to 28.8Kbps
|
||
|
||
EQUALIZATION:
|
||
Automatic adaptive equalizer with retrain
|
||
|
||
ECHO CANCELLATION:
|
||
Far end: 25ms echo span
|
||
Near end: Less than 17ms echo span
|
||
far end frequency offset compensation
|
||
Two-hop satellite delay capability
|
||
|
||
DIAGNOSTICS:
|
||
Local analog loopback (V.54 loop 3)
|
||
Local analog loopback with self-test
|
||
Local digital loopback (V.54 loop 1)
|
||
Remote digital loopback (V.54 loop2)
|
||
Remote digital loopback with self-test
|
||
|
||
OPERATING FEATURES:
|
||
LINE INTERFACE:
|
||
2-wire dail-up telephone lines
|
||
Tone and pulse dialing support
|
||
Auto-dial/Auto-answer
|
||
|
||
HARDWARE REQUIRMENTS:
|
||
IBM PC/XT/AT 386/486 or equivalent
|
||
|
||
PHYSICAL DIMENSIONS:
|
||
Internal:
|
||
Height: 4.0 inches (10.16cm)
|
||
depth: 13.3 inches (33.78cm)
|
||
|
||
External:
|
||
Height: 2.0 inches (5.1cm)
|
||
Depth: 8.0 inches (20.3cm)
|
||
Width: 10.0 inches (25.4cm)
|
||
|
||
REGULATORY COMPLIENCE:
|
||
Internal/External
|
||
FCC Part 68
|
||
FCC Part 15, Sub part J, Class A
|
||
CSA/DOC (Canada)
|
||
External
|
||
Enclosure & PCB assembly UL 1459 compliant
|
||
Wall-mount, plug-in power supply: UL, CSA registered
|
||
|
||
POWER (External):
|
||
60 Hz, 120VAC
|
||
22W(max) 14W(nominal)
|
||
|
||
ENGINEERING DESIGN:
|
||
16 bit microprocessor-based modem engine
|
||
Digital signal processor-based data pump
|
||
Data Access Arrangement (DAA)
|
||
256K non-volatile memory
|
||
|
||
WARRANTY:
|
||
5 years limited
|
||
|
||
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
|
||
FORVAL is a trademark of FORVAL AMERICA INC.
|
||
All product names are trademarks or registered trademarks of their
|
||
respective manufacturers
|
||
|
||
******************************************************************************
|
||
LOOKING INTO THE FUTURE:
|
||
|
||
IM19200 / SA19200 ULTRA HIGH SPEED MODEMS.
|
||
|
||
* Available the early part of this year.
|
||
* Transmission of 21.6Kbps allowing throughput of over 57.6 Kbps with
|
||
data compression.
|
||
* FORVAL LINK (tm) upgrades modem performance over the phone.
|
||
* Advanced error correction for protection of data at all speeds.
|
||
* Compatibility with CCITT dial-up standards
|
||
* Compatibility with the Hayes (tm) "AT" command set and a wide range
|
||
of communications software.
|
||
* SA19200 has the LCD display providing complete insight into modem
|
||
operations. Can be positioned horizontally or vertically.
|
||
* 5 Year Warranty
|
||
|
||
|
||
PERFORMANCE WITHOUT COMPROMISE:
|
||
|
||
The V.42 error correction and V.42bis data compression ensure data
|
||
integrity at any speed. Sophisticated engineering and CCITT standards
|
||
are built into the modems. The modems automatically negotiate CCITT
|
||
standards when connecting with slower modems at fall-back speeds
|
||
ranging from 14400, 12000, 9600, 4800, 2400, 1200 to 300 bps. You can
|
||
also set these levels manually.
|
||
|
||
UPGRADES ARE JUST A PHONE CALL AWAY:
|
||
|
||
With FORVAL-LINK (tm) software and a phone call to our headquarters,
|
||
you can upgrade your modem instantly and maintain the technological
|
||
edge. Costly obsolescence is virtually eliminated.
|
||
|
||
SA19200 MODEMS
|
||
|
||
Like all Forval stand-alone modems, the SA19200 can be adapted with a
|
||
bookend base for use as a slimline tower. When desktop space is at a
|
||
premium, this tower configuration has a footprint of only 16 square
|
||
inches. Of course, you can also set it in the standard horizontal
|
||
position.
|
||
|
||
COMPATIBILITY: SPEEDS:
|
||
|
||
21,600 BPS
|
||
Proprietary mode 21.6 Kbps
|
||
19.2 Kbps
|
||
16.8 Kbps
|
||
14.4 Kbps
|
||
CCITT V.32Bis 14400/12000 bps
|
||
CCITT V.32 9600/4800 bps
|
||
CCITT V.22Bis 2400/1200 bps
|
||
BELL 212A 1200 bps
|
||
BELL 103 300 bps
|
||
|
||
|
||
|
||
INFORMATION:
|
||
|
||
|
||
The IM19200/SA19200 modems will be a proprietary speed, however when
|
||
the CCITT approves a 19.2 Kbps, this modem will be able to be configured
|
||
via the FORVAL-LINK (tm) to be fully compatible with the new standard.
|
||
Which means that when the standard is approved, this modem will not be
|
||
obsolete.
|
||
|
||
The IM14400/SA14400 modems are also fully capabable of being upgraded
|
||
via the FORVAL-LINK (tm) to make them fully compatible at the 19.2 Kbps
|
||
speeds.
|
||
|
||
All these modems will also be able to be upgraded in the later part of
|
||
this year to have FAX capabilities. Again by use of the FORVAL-LINK (tm)
|
||
|
||
I guess it is easy to see why they say:
|
||
|
||
" FORVAL MODEMS ARE THE MODEMS WITH A FUTURE "
|
||
|
||
|
||
|
||
Contact Suburban Software BBS for pricing and availability:
|
||
|
||
(708)636-6694 FORVAL IM14400 (Internal)
|
||
(708)636-6695 FORVAL SA14400 (External)
|
||
(708)636-6697 US Robotics DS
|
||
|