AST RESEARCH, INC. TECHNICAL BULLETIN #0773 08-25-92
|
|
|
|
=============================================================================
|
|
|
|
|
|
3COM COMPATIBILITY IN AST EISA SYSTEMS
|
|
|
|
|
|
PROBLEM: There is a bus timing problem with 3COM's 3C507 Coax board
|
|
previous to modification 11, revision B and on the 3C507 TP
|
|
board modification 4, revision B.
|
|
|
|
CAUSE: When 3COM 3C507 Coax and 3C507 TP network interface cards are
|
|
installed in AST EISA based systems, the following symptoms
|
|
will occur:
|
|
|
|
- Intermittent lock ups
|
|
- Unreliable performance
|
|
- ABEND (NetWare)
|
|
- Trap Errors (OS/2)
|
|
|
|
SYSTEMS
|
|
AFFECTED: 386 Tower EISA, 486 Tower EISA, Premium SE, Power Premium, and
|
|
486 Desktop EISA.
|
|
|
|
SOLUTION: The following revisions must be installed to fix the problem:
|
|
|
|
The 3C507 Coax board must be a modification 11 or higher and
|
|
of revision B or higher. This information is located in the
|
|
upper right hand column of the board and is displayed as
|
|
follows:
|
|
|
|
ASSY 6750-11 REV B
|
|
|
|
The 3C507 TP board must be a modification 04 or higher and of
|
|
revision B or higher. This information is located in the
|
|
upper right hand column of the board and is displayed as
|
|
follows:
|
|
|
|
ASSY 7508-04 REV B
|
|
|
|
Customers with the above problem should call 3COM's RMA
|
|
department for an upgrade at (800) 876-3266.
|