AST RESEARCH, INC. TECHNICAL BULLETIN #0743 01-24-92
|
|
|
|
=============================================================================
|
|
|
|
|
|
AST PREMIUM EXEC 386 AND HEALTHDYNE SOFTWARE
|
|
|
|
|
|
PROBLEM: When the Healthdyne database software accesses the math co-
|
|
processor in a Premium Exec 386/SX-20 the following error
|
|
message "Stack Frame Error" displays and then returns to a dos
|
|
prompt.
|
|
|
|
AFFECTED
|
|
SYSTEMS: Premium Exec 386/SX-20 and Premium Exec 386SX-25
|
|
|
|
CAUSE: The software when started with a batch file "GO 1" mis-
|
|
identifies the L.C.D. screen and the environment created is
|
|
incorrect. The correct environment is created by the software
|
|
if the screen is identified as color CGA, EGA, or VGA display.
|
|
|
|
SOLUTION: Revision "B" of the software has been released by Healthdyne
|
|
that detects the display attached thereby correcting the above
|
|
problem. A temporary solution is to start the program with
|
|
the "GO 2" batch file, which identifies the screen as a VGA
|
|
display.
|