AST RESEARCH, INC. TECHNICAL BULLETIN #0720 11-12-91
|
|
|
|
=============================================================================
|
|
|
|
|
|
AST PREMIUM 486/33 TOWER EISA AND DPTFMT PROGRAM
|
|
|
|
|
|
PROBLEM: When installing SCO UNIX software on a Premium 486/33 Tower
|
|
EISA system with the DPT Host Bus adapter provided by AST, the
|
|
following error will be displayed during installation:
|
|
|
|
"WARNING: No Configuration Information for SDisk Unit 0."
|
|
|
|
AFFECTED
|
|
SYSTEMS: AST Premium 486/33 Tower EISA with the following system board:
|
|
|
|
202377-001
|
|
|
|
CAUSE: AST's DPTFMT program does not configure the hard drive type
|
|
properly.
|
|
|
|
SOLUTION: This problem has been resolved with release 1.01 of AST's
|
|
Driver Support Diskette. Customers experiencing this problem
|
|
should contact AST and order the following Software upgrade
|
|
and Installation Reference document:
|
|
|
|
PART NUMBER DESCRIPTION
|
|
|
|
910452-005 Software upgrade Revision A Release 1.01
|
|
001436-001A Installation Reference document
|