AST RESEARCH, INC. TECHNICAL BULLETIN #0678A 02-05-92
|
|
|
|
=============================================================================
|
|
|
|
|
|
PREMIUM EXEC BATTERY MANAGEMENT CONTROLLER
|
|
|
|
|
|
Under certain circumstances, some Premium Exec 386SX/20 computers may exhibit
|
|
one or more of the following problems when connected to the AC adapter after
|
|
the battery has been completely discharged:
|
|
|
|
- Battery will not charge completely.
|
|
|
|
- Over charge of battery.
|
|
|
|
- Erroneous battery charge level indicators (LED) when connected to the
|
|
AC Adapter.
|
|
|
|
- Low battery alarm when connected to the AC Adapter.
|
|
|
|
- Intermittent loss of display when booting.
|
|
|
|
To resolve these problems, it is necessary to reset the Battery Management
|
|
Controller (BMC) chip. To accomplish this, follow the steps listed below:
|
|
|
|
1. Power off the Premium Exec.
|
|
|
|
2. Disconnect the AC Adapter from the Premium Exec.
|
|
|
|
3. Wait approximately 10 to 15 seconds, reconnect the AC Adapter to the
|
|
Premium Exec.
|
|
|
|
4. Power the Premium Exec back on.
|
|
|
|
If this does not resolve the problem, the system may have a defective BMC
|
|
chip. Contact AST or your nearest AST Authorized Service Center to have this
|
|
chip replaced (re: Field Change Notice #0058).
|