AST RESEARCH, INC. TECHNICAL BULLETIN #TB-0339 12/10/87
|
||
|
||
|
||
AST-5250 ASYNC DIALUP - POSSIBLE CONFIGURATION PROBLEMS
|
||
|
||
|
||
Here is some additional information that is not contained in
|
||
the file README that comes on the software diskette. (The
|
||
version that this information was obtained from was version
|
||
4.14 of the AST-5250 Async. Dialup).
|
||
|
||
The setup for AST modems operating at speeds greater than 2400
|
||
baud includes a command for MNP error correction in reliable
|
||
mode (\N2). MNP error correction has been found to cause
|
||
problems on certain kinds of calls with the AST-5250 Async
|
||
Dialup. Several examples include: Canadian phone lines and
|
||
long-distance calls that use TASI multiplexing. It appears
|
||
that the telephone company equipment is filtering part of the
|
||
signal in these cases. This can lead to communications errors
|
||
such as "Master not communicating with PC" or cause System/3X
|
||
screens to be sent as many as 18 times as reported from a
|
||
Canadian site that examined the signals with a protocol
|
||
analyzer. If these errors occur, it may be necessary to change
|
||
the modem initialization string so that (\N2) becomes (\N1).
|
||
|
||
Additionally, problems have been reported with some modems
|
||
timing out before the slave sends its identification. There
|
||
have also been problems reported when customers have used
|
||
hardware flow control with their modems. Hayes and AST modems
|
||
appear to function properly with no errors of these types.
|
||
|
||
|
||
References:
|
||
----------
|
||
-AT&T Technical Journal
|
||
-AST 2400, 2X2400, 2X9600 modem user's manuals
|
||
-Hayes Smartmodem 2400 user's manual
|
||
|
||
|
||
|
||
|