AST RESEARCH TECHNICAL BULLETIN TB-0269 03/31/87
|
||
|
||
|
||
AST TURBOLASER / HARVARD PRESENTATION GRAPHICS
|
||
|
||
|
||
PROBLEM: When plotting a chart or graphics using TurboLaser
|
||
plotter emulations in HPGL mode, the output is printed in reverse
|
||
image. Diagrams, charts and characters are white on a black
|
||
background instead of black on a white background.
|
||
|
||
AST Systems Engineering attributes this problem to nonstandard
|
||
plotter commands being sent to the printer from the Harvard
|
||
Presentation program.
|
||
|
||
CONFIGURATION:
|
||
|
||
AST TurboLaser Model 800
|
||
|
||
Software Versions 1.10 or 1.21
|
||
|
||
HPGL Emulations HP 7440, 7470A, 7475A, 7510, 7550A
|
||
IBM 7371 and 7372
|
||
|
||
Harvard Presentation Graphics Revision A
|
||
|
||
IBM PC/AT, AST PREMIUM/286
|
||
|
||
|
||
ALTERNATE METHOD OF PRINTING:
|
||
|
||
The user can obtain a satisfactory output using the TurboLaser
|
||
Epson emulations and selecting the "High" resolution option for
|
||
printer output.
|
||
|