AST RESEARCH TECHNICAL BULLETIN TB-0113 9-06-85
|
||
|
||
|
||
PCNET (COAX) SELFTEST PROBLEM
|
||
|
||
|
||
The PCnet SELFTEST program will, under certain conditions, give a
|
||
false indication of failure when operated with Release 3.0 or
|
||
above. Only a few boards have experienced this problem, and can
|
||
be attributed to a build-up of tolerances of components used in
|
||
the construction of these boards. There is no components
|
||
associated with any range of serial numbers, so the problem may
|
||
be experienced with new or old boards.
|
||
|
||
If the following message is displayed after the Interrput
|
||
selection is made:
|
||
|
||
Select Interrupt 2 (Default), 3, 4, or 5> (n)
|
||
|
||
*Response to unexpected interrupt 0**
|
||
*No response from selected interrupt (n) **
|
||
|
||
1. Stop test and reconnect the system cable or terminator
|
||
plug to the BNC connector of the PCB.
|
||
|
||
2. Restart the test.
|
||
|
||
3. If test runs successfully, consider the board as having
|
||
passed Selftest.
|
||
|
||
4. To insure correct Network operation, Nettest should also
|
||
be run.
|
||
|
||
A note should be entered into the PCnet Users Manual under the
|
||
"SELFTEST" command description referencing the above information.
|
||
|