AST RESEARCH TECHNICAL BULLETIN TB-0012 5-16-84
|
||
|
||
|
||
MEGAPLUS II IRQ SILKSCREEN CONFLICT
|
||
|
||
|
||
In certain revisions of the MegaPlus II, the silkscreen for the
|
||
IRQ block is in error. The correct silkscreen for the IRQ jumper
|
||
block should be:
|
||
|
||
* * * * * * * * *
|
||
< JUMPER BLOCK
|
||
* * * * * * * * *
|
||
CORRECT
|
||
2 2 3 3 4 4 5 5 7
|
||
|
||
S C S C C S C
|
||
|
||
The incorrect silkscreen is as follows:
|
||
|
||
* * * * * * * * *
|
||
< JUMPER BLOCK
|
||
* * * * * * * * *
|
||
INCORRECT
|
||
2 2 3 3 4 4 5 5 7
|
||
|
||
S C S S C C S C
|
||
|
||
Notice that the position labeled 3S and 3 are swapped, and 4 was
|
||
changed to 4S.
|
||
|
||
Listed below are the revision levels that have the incorrect
|
||
silkscreen for ASSY 03-01165-01 MegaPlus II board:
|
||
|
||
REV AO
|
||
|
||
REV C
|
||
|
||
REV D
|
||
|
||
REV E
|
||
|