! BUSY VERIFICATION CIRCUIT part ][ By: The Wizard of the World of Cryton!
|
|||
|
! !
|
|||
|
+============================================================================+
|
|||
|
|
|||
|
|
|||
|
[1]: Busy Verification circuits allow an operator to bridge the path between
|
|||
|
two connected ports, to verify that either or both are busy, and to speak to
|
|||
|
parties using the monitored ports (3-way conference). These circuits are
|
|||
|
considered to be service port circuits. One complete busy verification circuit
|
|||
|
consists of two PWBA's: 814434-026 and 814434-046. This figure shows the
|
|||
|
difference between a normal call connection and a busy verification connection
|
|||
|
as well as showing the interconnection of circuits associated with a busy
|
|||
|
verification call.
|
|||
|
|
|||
|
Normal Call Connection Versus Busy Verification Connection
|
|||
|
----------------------------------------------------------
|
|||
|
|
|||
|
NORMAL CALL CONNECTION:
|
|||
|
+----------+ +----------+ +-----------+
|
|||
|
+------+ | | | | | TIMESLOT |
|
|||
|
Phone<--->|PORT A|<------>|- - - - - |<--->|- - - - - |<--->|- - - + |
|
|||
|
+------+ |PORT GROUP| |PORT GROUP| | ! |
|
|||
|
-------+ |MUX/DEMUX | | CONTROL | | ! |
|
|||
|
Phone<--->|PORT A|<------>|- - - - - |<--->|- - - - - |<--->|- - - + |
|
|||
|
+------+ | | | | |INTERCHANGE|
|
|||
|
+----------+ +----------+ +-----------+
|
|||
|
|
|||
|
BUSY VERIFICATION CONNECTION:
|
|||
|
|
|||
|
+----------+ +----------+ +-----------+
|
|||
|
+------+ | | | | | TIMESLOT |
|
|||
|
Phone<--->|PORT A|<------>|- - - - - |<--->|- - - - - |<--->|- - - + |
|
|||
|
+------+ |PORT GROUP| |PORT GROUP| | ! |
|
|||
|
-------+ |MUX/DEMUX | | CONTROL | | ! |
|
|||
|
Phone<--->|PORT A|<------>|- - - - - |<--->|- - - - - |<--->|- + + |
|
|||
|
+------+ | | | | | ! ! |
|
|||
|
| | | | | ! ! |
|
|||
|
BUSY +--------+ | | | | | ! ! |
|
|||
|
VERIFI- | + - - -|<----->|- - - - - |<--->|- - - - - |<--->|- + ! |
|
|||
|
CATION | * - - -|<----->|- - - - - |<--->|- - - - - |<--->|- - - + |
|
|||
|
CURCUIT | + - - -|<----->|- - - - - |<--->|- - - - - |<--->|- + |
|
|||
|
+--------+ | | | | | ! |
|
|||
|
| | | | | ! |
|
|||
|
TO/FROM +------+ | | | | | ! |
|
|||
|
MONITOR<->|PORT C|<------>|- - - - - |<--->|- - - - - |<--->|- + |
|
|||
|
ING OP. +------+ | | | | |INTERCHANGE|
|
|||
|
+----------+ +----------+ +-----------+
|
|||
|
|
|||
|
[2]: The busy verification circuit consists of three operational amplifiers
|
|||
|
and three sets of XMT OUT and RCV IN leads. See diagram...
|
|||
|
|
|||
|
Busy Verification Circuit, Block Diagram
|
|||
|
----------------------------------------
|
|||
|
|
|||
|
Amplifier A
|
|||
|
|\ +-----+
|
|||
|
+------------>| \_____XMT_OUT_\| |
|
|||
|
! +------->| / /| |
|
|||
|
! ! |/ |CODEC|
|
|||
|
! ! RCV IN | |
|
|||
|
! ! +---------------------| |
|
|||
|
! ! ! Amplifier B +-----+
|
|||
|
! ! ! |\ +-----+
|
|||
|
*------------->| \____XMT_OUT_\| |
|
|||
|
| ! *---->| / /| |
|
|||
|
! ! ! |/ |CODEC|
|
|||
|
! ! ! RCV IN | |
|
|||
|
! *-------------------------| |
|
|||
|
! ! ! Amplifier C +-----+
|
|||
|
! ! ! |\ +-----+
|
|||
|
! ! +---->| \____XMT_OUT_\| |
|
|||
|
! +-------->| / /| |
|
|||
|
! |/ |CODEC|
|
|||
|
! RCV IN | |
|
|||
|
+------------------------------| |
|
|||
|
+-----+
|
|||
|
|
|||
|
The inputs to each amplifier are the RCV IN signals from the two sets of leads
|
|||
|
not associated with that amplifier. Each RCV IN signal is the output of one of
|
|||
|
three CODEC's on PWBA 814434-026. The output of each amplifier is an XMT OUT
|
|||
|
signal, which is the input to one of three CODEC's. With this arrangement, two
|
|||
|
of the sets of busy verification circuit leads are switched into the two
|
|||
|
conversation paths that provide two-way communication between the two ports to
|
|||
|
be monitored. Signals on both paths then are fed into the amplifier associated
|
|||
|
with the third set of leads. This third set of leads is switched to the port
|
|||
|
that serves the monitoring operator. Thus, the XMT OUT lead from the third set
|
|||
|
carries voice signals from both monitored ports for transfer to the operator.
|
|||
|
The RCV IN lead of the third set carries the operators message to the parties
|
|||
|
on both monitored ports.
|
|||
|
|
|||
|
[3]: Each of the operational amplifiers has unity gain. A coupling capacitor
|
|||
|
and voltage divider on the RCV IN analog input provides the proper frequency
|
|||
|
response and signal level for the amplifier inputs.
|
|||
|
|
|||
|
[4]: The busy verification circuit is an optional and nonredundant portion of
|
|||
|
line and/or line and service group cells, using three port positions per cell.
|
|||
|
A component failure on this circuit never affects service to more then three
|
|||
|
ports and, therefore, is considered to be a minor failure. A component failure
|
|||
|
can cause loss of busy verification monitoring and/or loss of voice
|
|||
|
transmission through up to three ports.
|
|||
|
|
|||
|
Thats all for this time, stay tuned for Part 3!!! Phreak on dudes!
|
|||
|
|
|||
|
\
|
|||
|
-===THE=WIZARD=]>>>)}
|
|||
|
/
|
|||
|
|
|||
|
(*)- The *ELITE* Phreaker's Club -(*)
|