! Bell Telephone Info !
|
|||
|
\-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-/
|
|||
|
|
|||
|
|
|||
|
***************************************
|
|||
|
|
|||
|
BRIDGING HEADS, RESIDENTIAL AND
|
|||
|
BUSINESS MULTILINE DISTRIBUTION BOXES,
|
|||
|
LINE AND TRUNK SPLITTERS, AND
|
|||
|
OTHER BELL SYSTEM WIRE TERMINATIONS.
|
|||
|
|
|||
|
- HOW TO USE, AND/OR ABUSE THEM -
|
|||
|
|
|||
|
(INCLUDING A TUTORIAL ON BASIC TELE-
|
|||
|
PHONE EAVESDROPPING TECHNIQUES.)
|
|||
|
|
|||
|
***************************************
|
|||
|
|
|||
|
WRITTEN BY : PHUCKED
|
|||
|
AGENT
|
|||
|
04
|
|||
|
|
|||
|
***************************************
|
|||
|
|
|||
|
IN THIS ARTICLE, I WILL FIRST
|
|||
|
BESCRIBE THE TERMINATION, WIRING, AND
|
|||
|
TERMINAL HARDWARE MOST COMMONLY USED
|
|||
|
IN THE BELL SYSTEM, AND I WILL INCLUDE
|
|||
|
A SECTION ON METHODS OF USING THEM.
|
|||
|
|
|||
|
***************************************
|
|||
|
|
|||
|
-------------
|
|||
|
LOCAL NETWORK
|
|||
|
-------------
|
|||
|
|
|||
|
THE LOCAL TELEPHONE NETWORK
|
|||
|
BETWEEN THE CENTRAL OFFICE/EXCHANGE AND
|
|||
|
THE TELEPHONE SUBSCRIBERS CAN BE
|
|||
|
BREIFLY DESCRIBED AS FOLLOWS:
|
|||
|
FROM THE CENTRAL OFFICE (OR
|
|||
|
LOCAL EXCHANGE) OF A CERTAIN PREFIX
|
|||
|
(ES), UNDERGROUND AREA FEEDER TRUNKS
|
|||
|
GO TO EACH AREA THAT HAS THAT PREFIX.
|
|||
|
(USUALLY MORE THAN ONE PREFIX PER AREA)
|
|||
|
AT EVERY FEW STREETS OR TRACT AREAS,
|
|||
|
THE UNDERGROUND CABLES SURFACE. THEY
|
|||
|
THEN GO TO THE SECONDARY TERMINATION,
|
|||
|
(THE AERIAL TELEPHONE FEEDER CABLE)
|
|||
|
(OR BACK UNDERGROUND, DEPENDING ON THE
|
|||
|
AREA) AND THEN TO THE SUBSRIBERS HOUSE
|
|||
|
(OR IN THE CASE OF AN APARTMENT
|
|||
|
BUILDING OR MUTLILINE BUSINESS, TO
|
|||
|
A SPLITTER OR DISTRIBUTION BOX/PANEL).
|
|||
|
|
|||
|
****************************************
|
|||
|
NOW THAT WE HAVE THE BASICS, I'LL TRY
|
|||
|
AND GO IN-DEPTH ON THE SUBJECT.
|
|||
|
|
|||
|
------------------
|
|||
|
UNDERGROUND CABLES
|
|||
|
------------------
|
|||
|
|
|||
|
THESE ARE SOMETIMES INTER-
|
|||
|
OFFICE TRUNKS, BUT USUALLY IN A RESID-
|
|||
|
ENTIAL AREA THEY ARE FEEDER GROUPS THAT
|
|||
|
GO OTO BRIDGING HEADS OR DISTRIBUTION
|
|||
|
CASES. THE CABLES ARE ABOUT 2-3 INCHES
|
|||
|
THICK (VARIES), AND ARE EITHER IN A
|
|||
|
METAL OR PVC-TYPE PIPE (OR SIMILAR).
|
|||
|
RARELY (MAYBE NOT IN SOME REMOTE RURAL
|
|||
|
AREAS) ARE THE CABLES JUST 'ALONE' IN
|
|||
|
THE GROUND. INSTEAD, THEY ARE USUALLY
|
|||
|
IN AN UNDERGROUND CEMENT TUNNEL
|
|||
|
(RESEMBLES A SMALL SEWER OR STORMDRAIN)
|
|||
|
. THE MANHOLES ARE >HEAVY< AND WILL SAY
|
|||
|
'BELL SYSTEM' ON THEM. THEY CAN BE OPEN
|
|||
|
ED WITH A 1/2 INCH WIDE CROWBAR (HOOK
|
|||
|
SIDE) INSERTED IN THE TOP RECTANGULAR
|
|||
|
HOLE. IF YOU GET IT OPEN, GO INSIDE!!
|
|||
|
THERE ARE LADDER RUNGS TO HELP YOU
|
|||
|
CLIMB DOWN. YOU WILL SEE THE CABLE
|
|||
|
PIPES ON THE WALL, WITH THE BLUE AND
|
|||
|
WHITE STRIPED ONE BEING THE INTER-
|
|||
|
OFFICE TRUNK GRP (AT LEAST IN MY AREA).
|
|||
|
THE OTHERS ARE LOCAL LINES, AND ARE
|
|||
|
USUALLY MARKED OR COLOR CODED. THERE
|
|||
|
IS ALMOST ALWAYS A POSTED COLOR CODE
|
|||
|
CHART ON THE WALL, NOT TO MENTION
|
|||
|
TELCO MANUALS DESCRIBING THE CABLES
|
|||
|
AND TERMINALS, SO I NEED NOT GET INTO
|
|||
|
DETAIL. AGAIN: >IF YOU CAN GET INTO A
|
|||
|
BELL MANHOLE, DO IT!, IT WILL PAY OFF
|
|||
|
<. ALSO, THERE IS USUALLY SOME KIND
|
|||
|
OF TEST EQUIPMENT, AND OFTEN BELL
|
|||
|
TEST SETS ARE LEFT IN THERE.
|
|||
|
SO GET YOUR CROWBARS!
|
|||
|
|
|||
|
****************************************
|
|||
|
--------------
|
|||
|
BRIDGING HEADS - (WE MS2'S)
|
|||
|
--------------
|
|||
|
|
|||
|
THE INNOCENT-LOOKING GRAYISH-
|
|||
|
GREEN BOXES.
|
|||
|
WHEN IN GROUPS OF TWO OR THREE, THEY
|
|||
|
ARE FOR SECONDAY/TERTIARY TERMINATION
|
|||
|
AND ACCESS POINTS (BRIDGED ACCESS).
|
|||
|
THESE ARE THE WESTERN ELECTRIC SAI
|
|||
|
55 OR 22/E TERMINAL CASES. THEY HOLD
|
|||
|
ON THE ORDER OF 900-1200 CABLE PAIRS.
|
|||
|
THIS IS USUALLY THE SECOND TERM. POSI
|
|||
|
TION ON THE LOCAL LOOP (AFTER THE MTF
|
|||
|
FRAME AT THE CO/ OR THE UNDERGROUND
|
|||
|
'FTP' POSITION).
|
|||
|
THESE CAN BE EITHER
|
|||
|
TRUNK BRIDGES OR BRIDGING FOR RESIDEN
|
|||
|
CES. THE AREA FEEDER BRIDGING HEADS
|
|||
|
ARE USUALLY LARGER, AND THEY HAVE THE
|
|||
|
'WESTERN ELECTRIC' LOGO AT THE BOTTOM,
|
|||
|
WHEREAS THE NORMAL BRIDGING HEADS
|
|||
|
(WHICH MAY BE DIFFERENT IN SOME AREAS-
|
|||
|
DEPENDING ON THE COMPANY YOU ARE
|
|||
|
SERVED BY. GTE B.H'S LOOK SLIGHTLY
|
|||
|
DIFFERENT. ALSO, DO NOT BE FOOLED
|
|||
|
BY SPRINKLER BOXES!)
|
|||
|
CAN BE FOUND IN JUST ABOUT EVERY CITY.
|
|||
|
TO OPEN A BRIDGING HEAD:
|
|||
|
IF IT IS LOCKED (AND YOU'RE FEELING
|
|||
|
DESTRUCTIVE), PUT A HAMMER OR CROWBAR
|
|||
|
(THE SAME ONE YOU USED ON THE MANHOLE
|
|||
|
) IN THE SLOT ABOVE THE TOP HINGE OF
|
|||
|
THE RIGHT DOOR. PULL HARD, AND THE
|
|||
|
DORR WILL RIP OFF. VERY EFFECTIVE!
|
|||
|
IF IT ISN'T LOCKED (AS USUAL),
|
|||
|
TAKE A 7/16 INCH HEX SOCKET AND
|
|||
|
WITH IT, TURN THE BOLT ABOUT 1/8 OF A
|
|||
|
TURN TO THE LEFT (YOU SHOULD HEAR
|
|||
|
A SPRING RELEASE INSIDE). HOLDING THE
|
|||
|
BOLT, TURN THE HANDLE ALL THE WAY TO
|
|||
|
THE RIGHT AND PULL OUT.
|
|||
|
NOW INSIDE, FIRST CHECK FOR
|
|||
|
A TEST-SET (WHICH ARE OFTEN LEFT BY
|
|||
|
BELL EMPLOYEES). THERE SHOULD BE A
|
|||
|
PANEL OF CABLE PAIRS + SCREW TERMINALS
|
|||
|
(TYPE 45/47IB REGULAR BINDERS) . PUSH
|
|||
|
THE PANEL BACK ABOUT AN INCH OR SO,
|
|||
|
AND ROTATE THE TOP LATCH (ROUND WITH
|
|||
|
A FLAT SECTION) DOWNWARD. RELEASE THE
|
|||
|
PANEL AND IT WILL FALL ALL THE WAY
|
|||
|
FORWARD. THERE IS USUALLY A LARGE AMO-
|
|||
|
UNT OF WIRE AND EXTRA TERMINALS.
|
|||
|
THE TEST-SETS ARE OFTEN HIDDEN HERE,
|
|||
|
SO DONT OVERLOOK IT (400 FOOT ROLLS OF
|
|||
|
#22 SOLID WIRE ARE OFTEN NEAR THE TOP
|
|||
|
IN THE BACK OF THE BOX. 'BORROW THEM')
|
|||
|
. ON THE RIGHT DOOR IS A METAL BOX OF
|
|||
|
INSULATORS, BINDERS, CLIPS, ETC. TAKE
|
|||
|
A FEW (COMPLIMENTS OF BELL...). ON EACH
|
|||
|
DOOR IS A USEFUL ROUND METAL DEVICE.
|
|||
|
(SAYS 'INSERT GENTLY' OR 'CLAMP GENTLY
|
|||
|
- DO NOT OVERTIGHTEN' ETC..) ON THE
|
|||
|
FRONT OF THE DISC, YOU SHOULD FIND TWO
|
|||
|
TERMINALS. THESE ARE FOR YOUR TEST SET.
|
|||
|
(IF YOU DONT HAVE ONE, DONT DEPAIR -
|
|||
|
I'LL SHOW YOU WAYS TO MAKE BASIC TEST
|
|||
|
SETS LATER IN THIS ARTICLE).
|
|||
|
HOOKING THE RING (-) WIRE TO THE
|
|||
|
'R' TERMINAL; AND THE TIP (+) WIRE
|
|||
|
TO THE OTHER. (BY THE WAY, AN EASY WAY
|
|||
|
TO DETERMINE THE CORRECT POLARITY IS
|
|||
|
WITH A 1.5V LED. TAP IT TO THE TERM.
|
|||
|
PAIR, IF I DOESNT LIGHT, SWITCH THE
|
|||
|
POLES UNTIL IT DOES. WHEN IT LIGHTS,
|
|||
|
FIND THE LONGER OF THE TWO LED POLES.
|
|||
|
THIS ONE WILL BE ON THE TIP WIRE (+))
|
|||
|
BEHIND THE DISC IS A COILED UP CORD.
|
|||
|
THIS SHOULD HAVE A SPECIALIZED CONNECT-
|
|||
|
OR. ITS VERY USEFUL, BECAUSE YOU
|
|||
|
DONT HAVE TO KEEP CONNECTING AND
|
|||
|
DISCONNECTING THE FONE (TEST SET)
|
|||
|
ITSELF, AND THE CLIP IS DESIGNED TO AID
|
|||
|
IN LOCATING THE PAIR AND ASSURING THE
|
|||
|
CORRECT POLARITY.
|
|||
|
ON THE TERMINAL BOARD, THERE
|
|||
|
SHOULD BE ABOUT 20 PAIRS (RED/WHITE)
|
|||
|
PER ROW PER SIDE.
|
|||
|
HOOK THE CLIP TO ANY TERMINAL PAIR
|
|||
|
, AND YOU'RE SET! DIAL OUT IF YOU WANT,
|
|||
|
OR JUST LISTEN (IF SOMEONE'S ON THE
|
|||
|
LINE). LATER, I'LL SHOW YOU A WAY TO
|
|||
|
SET UP A TRUE 'TAP' THAT YOU CAN SET
|
|||
|
UP, AND WILL LET THE PERSON DIAL OUT
|
|||
|
ON HIS LINE AND RECEIVE CALLS AS
|
|||
|
NORMAL, AND YOU CAN LISTEN IN THE
|
|||
|
WHOLE TIME. MORE ABOUT THIS LATER...
|
|||
|
ON MAJOR PREFIX-AREA BRIDGING
|
|||
|
HEADS ('SAI' FOR AREA C.O. FEEDER CABLE
|
|||
|
) YOU CAN SEE TEMPORARY 'LOCAL LOOPS',
|
|||
|
WHICH ARE TWO CABLE PAIRS (CABLE
|
|||
|
PAIR = RING+TIP, A FONE LINE) THAT
|
|||
|
ARE DIRECTLY CONNECTED TO EACH OTHER
|
|||
|
ON THE TERMINAL BOARD. THESE 'CHEAP
|
|||
|
LOOPS' AS THEY ARE CALLED, DO NOT
|
|||
|
WORK NEARLY AS WELL AS THE EXISTING
|
|||
|
ONES SET UP IN THE SWITCHING HARDWARE
|
|||
|
AT THE EXCHANGE OFFICE. (TRY SCANNING
|
|||
|
YOUR PREFIXES' 00XX OR 99XX #'S.
|
|||
|
THE TONE SIDES WILL ANNOUNCE THEMSELVES
|
|||
|
WITH THE 1000 HZ LOOP TONE, AND THE
|
|||
|
HANG SIDE WILL GIVE NO RESPONSE. THE
|
|||
|
FIRST PERSON SHOULD DIAL THE 'HANG'
|
|||
|
SIDE, AND THE OTHER PERSON DIAL THE,
|
|||
|
TONE SIDE, AND THE TONE SHOULD STOP
|
|||
|
IF YOU HAVE GOT THE RIGHT LOOP).
|
|||
|
THE LOOPS ARE USED IN FRAME TERMINATI
|
|||
|
ON AND IN SONIC/600 OHM TERM. TESTING
|
|||
|
AND LINE/CABLE/FEEDER LOCATION.
|
|||
|
IF YOU WANT TO FIND THE NUMBER
|
|||
|
OF THE LINE THAT YOU'RE ON, YOU CAN
|
|||
|
EITHER TRY TO DECIPHER THE 'BRIDGING
|
|||
|
LOG' (OR WHATEVER), WHICH IS ON THE
|
|||
|
LEFT DOOR. IF THAT DOESNT WORK, YOU
|
|||
|
CAN USE THE FOLLWING:
|
|||
|
|
|||
|
---
|
|||
|
ANI # (AUTOMATIC NUMBER INDENTICATION)
|
|||
|
---
|
|||
|
THIS IS A TELCO TEST NUMBER
|
|||
|
THAT REPORTS TO YOU THE NUMBER THAT
|
|||
|
YOURE CALLING FROM (IT'S THE SAME,
|
|||
|
CHOPPY 'BELL BITCH' VOICE THAT YOU
|
|||
|
GET WHEN YOU REACH A DISCONNECTED #)
|
|||
|
(PIP OR ONE OF THE 11X SERIES ANNOUNCE
|
|||
|
MENT FRAME MACHINES.)
|
|||
|
|
|||
|
FOR THE 213 NPA - DIAL 1223
|
|||
|
213 NPA - (GTE AREAS) DIAL 114
|
|||
|
408 NPA - DIAL 760
|
|||
|
914 NPA - DIAL 990
|
|||
|
|
|||
|
THESE ARE EXTREMELY USEFUL WHEN MESSING
|
|||
|
WITH ANY KIND OF LINE TERMINALS,
|
|||
|
FEEDER BOXES, ETC.
|
|||
|
|
|||
|
----------
|
|||
|
|
|||
|
WHEN FINISHED, BE SURE TO CUT
|
|||
|
OFF THE CONNECTOR AND TAKE IT WITH YOU
|
|||
|
(THEY ARE VERY HANDY), AND CLOSE/LATCH
|
|||
|
THE BOX TO AVOID SUSPICION.
|
|||
|
|
|||
|
***************************************
|
|||
|
|
|||
|
------
|
|||
|
"CANS" - AERIAL-MOUNTED (TELEPHONE POLE
|
|||
|
------ TERMINAL) BRANCH FEEDER CABLE
|
|||
|
SPLITTER.
|
|||
|
|
|||
|
BASICALLY, TWO TYPES:
|
|||
|
|
|||
|
1> MS3A SERVICE AREA INTERFACE.
|
|||
|
(LARGE, RECTANGULAR SILVER BOX AT
|
|||
|
THE END OF EACH STREET.)
|
|||
|
|
|||
|
2> SERIES 600 LOADING COIL, INCLUDES
|
|||
|
THE MSX AERIAL DROP SPLITTER.
|
|||
|
(BLACK, ROUND OR RECTANGULAR THING
|
|||
|
AT EVERY TELEPHONE POLE.)
|
|||
|
|
|||
|
--------
|
|||
|
|
|||
|
TYPE 1 - THIS IS THE CASE THAT TAKES
|
|||
|
THE UNDERGROUND CABLE FROM THE BRIDGER
|
|||
|
AND RUNS IT TO THE AERIAL BRANCH FEEDER
|
|||
|
CABLE (THE LOWEST, LARGEST WIRE ON THE
|
|||
|
TELEPHONE POLE). THE BOX IS ALWAYS ON
|
|||
|
THE POLE NEAREST THE BRIGING HEAD,
|
|||
|
WHERE THE LINE COMES UP. LOOK FOR THE
|
|||
|
'CALL BEFORE YOU DIG - UNDERGROUND
|
|||
|
CABLE' STICKERS..
|
|||
|
THE CASE BOX IS HINGED, SO IF
|
|||
|
YOU WANT TO CLIMB THE POLE, YOU CAN
|
|||
|
OPEN IT WITH NO PROBLEMS. THESE USUALLY
|
|||
|
HAVE 2 ROWS OF TERMINAL SETS.
|
|||
|
(TOTAL APPROX. 200-600 PAIRS, DEPENDING
|
|||
|
ON THE AREA.) THESE ARE ALL THE CABLE
|
|||
|
PAIRS FOR YOUR STREET.
|
|||
|
. (ITS SIMILAR TO A MINIATURE BRIDGING
|
|||
|
HEAD). USE/ABUSE IT IN THE SAME MANNER
|
|||
|
AS WE DID BEFORE. (NOTE: ALL THE ACTIVE
|
|||
|
LINES CARRY FROM 15 TO 48 VDC, AND
|
|||
|
EVEN 90VAC (WHEN RINGING), SO BE
|
|||
|
CAREFUL - IT'S NOT GOING TO HURT YOU,
|
|||
|
BUT IT CAN SURPRISE YOU (AND IF
|
|||
|
YOU'RE HANGING BY ONE HAND FROM A TEL.
|
|||
|
POLE, IT >CAN< BE HARMFUL!))
|
|||
|
OH, BY THE WAY, IF YOU USE
|
|||
|
ANI ON EVERY PAIR AND YOU FIND ONE
|
|||
|
THAT ISNT IN USE ON YOUR STREET, YOU
|
|||
|
CAN HOOK IT UP FOR YOURSELF (ALMOST).
|
|||
|
ALSO, YOU HAVE TO BE ABLE TO IMPER-
|
|||
|
SONATE A TELCO TECHNICIAN AND REPORT
|
|||
|
THE NUMBER AS 'NEW ACTIVE' (GIVING
|
|||
|
A FAKE NAME AND FAKE REPORT, ETC)
|
|||
|
I DONT RECOMMEND THIS AND IT PROBABLY
|
|||
|
WONT (ALMOST POSITIVELY WONT) WORK,
|
|||
|
BUT THIS IS BASICALLY WHAT TELCO
|
|||
|
LINEMEN DO).*
|
|||
|
|
|||
|
|
|||
|
* THE USE OF THE 'TEST BOARD'
|
|||
|
(A 7D# FOR LINEMEN TESTS, OFTEN FOUND
|
|||
|
NXX-0003 OR NXX-0004) IS BEYOND THE
|
|||
|
SCOPE OF THIS ARTICLE, BUT WILL BE
|
|||
|
COVERED IN A FUTURE ARTICLE.
|
|||
|
|
|||
|
----
|
|||
|
|
|||
|
TYPE 2 - THIS IS THE SPLITTER BOX FOR
|
|||
|
THE AERIAL DROP WIRES FOR THE GROUP OF
|
|||
|
HOUSES AROUND THE POLE.
|
|||
|
(USUALLY 4 OR 5 HOUSES). USE IT
|
|||
|
LIKE I MENTIONED BEFORE. THE TERMINALS
|
|||
|
(20 OR SO) WILL BE IN 2 HORIZONTAL
|
|||
|
ROWS OF SETS. THE EXTRA WIRES THAT ARE
|
|||
|
JUST 'HANGING THERE' ARE PROVISIONS
|
|||
|
FOR EXTRA LINES TO RESIDENCES (1 EXTRA
|
|||
|
LINE PER HOUSE, THATS WHY THE INSANE
|
|||
|
CHARGE FOR LINE #3). IF ITS THE BOX FOR
|
|||
|
YOUR HOUSE ALSO, HAVE FUN AND SWAP
|
|||
|
LINES WITH YOUR NEIGHBOR! 'PIGGYBACK'
|
|||
|
THEM OR USE A CHEESEBOX FOR A LOOP-ARO
|
|||
|
UND, ETC.
|
|||
|
AGAIN, I DONT RECOMMEND THIS, AND ITS
|
|||
|
DIFFICULT TO DO IT CORRECTLY. (ALTHOUGH
|
|||
|
USEFUL)
|
|||
|
|
|||
|
***************************************
|
|||
|
---------------------------------------
|
|||
|
|
|||
|
|
|||
|
DOWNLOADED FROM P-80 SYSTEMS.
|
|||
|
|
|||
|
|