Title: Bugging, detecting bugs
|
||
|
|
||
|
|
||
|
|
||
|
[ Detecting Bugs on Home Phones ]
|
||
|
[ By: Dr. Jimmy and Mr. Jim ]
|
||
|
|
||
|
|
||
|
FIRST OF ALL TO TEST FOR BUGS, YOU NEED A VOM (MULTIMETER) THE HIGHER
|
||
|
THE IMPEDANCE THE BETTER (A DIGITAL WITH FET CIRCUITRY OR A VACUUM TUBE
|
||
|
VOLT METER IS THE BEST).
|
||
|
|
||
|
FIRST DISCONNECT THE PHONE LINE(S) AT BOTH ENDS. UNDO THE PHONE INSTRUMENT
|
||
|
AND HOOK IT UP TO THE ENTRY POINT OF THE PHONE LINE FROM THE OUTSIDE WORLD
|
||
|
(MA BELL DOES NOT LIKE YOU CUT HER OFF COMPLETELY.) THE SCHEME IS THE PHYSI-
|
||
|
CALLY ISOLATE YOUR HOUSE, APARTMENT, FROM THE OUTSIDE WORLD. BUT BEFORE YOU
|
||
|
DO THIS MEASURE THE LINE VOLTAGE (IT SHOULD BE APPROXIMATELY 48 VOLTS).
|
||
|
|
||
|
NOW WITH THE WIRES DISCONNECTED AT BOTH ENDS SET YOUR RESISTANCE SCALE TO A
|
||
|
HIGH READING AND MEASURE THE RESISTANCE OF THE PHONE LINE, IT SHOULD BE VERY
|
||
|
HIGH ON THE ORDER OF MILLION OHMS OR MORE, THIS IS THE NORMAL CONDITION,
|
||
|
SINCE YOU ARE MEASURING THE RESISTANCE OF AN OPEN CIRCUIT. IF IT IS MUCH LESS,
|
||
|
SAY 50-100KOHMS THEN YOU HAVE A DEVICE ON THE LINE THAT DOES NOT BELONG THERE,
|
||
|
PROBABLY A PARALLEL BUG.
|
||
|
|
||
|
NOW TWIST THE END OF THE DISCONNECTED WIRE AND GO TO THE OTHER END AND
|
||
|
MEASURE THE RESISTANCE OF THIS. THIS RESISTANCE SHOULD BE ABOUT ONE OHM OR
|
||
|
TWO AT THE MOST IN A BIG HOUSE WITH A LOT OF PHONES. IF IT IS MORE, THEN
|
||
|
YOU PROBABLY HAVE A SERIES BUG.
|
||
|
|
||
|
IF IN THE FIRST CASE, TAKING PARALLEL MEASUREMENTS USING A METER (NOT LED/
|
||
|
LCD) AND YOU NOTICE A "KICK" IN THE NEEDLE, YOU PROBABLY HAVE A LINE TAP
|
||
|
|
||
|
NOW IF YOU ALSO MAKE A MEASUREMENT WITH THE WIRE END TWISTED TOGETHER AND YOU
|
||
|
NOTICE THE RESISTANCE READS ABOUT 1-2KOHMS, THEN YOU MAY HAVE A DROP-OUT
|
||
|
RELAY. A DROP-OUT RELAY IS A RELAY THAT SENSES A PHONE GOING OFF HOOK, AND
|
||
|
SIGNALS A TAPE RECORDER TO START RECORDING.
|
||
|
|
||
|
ANOTHER TEST TO DO WITH THE PHONES STIL HOOKED UP TO THE OUTSIDE WORLD, ON HOOK
|
||
|
VOLTAGE IS ABOUT 48 VOLTS AND OFF HOOK IS ABOUT 6-10 VOLTS. ANY OTHER CON-
|
||
|
DITIONS MAY MEAN TELEPHONE SURVEILLANCE
|
||
|
|
||
|
IF YOU USE A WIDE RANGE AUDIO FREQUENCY GENERATOR AND CALL YOU HOUSE, APARTMENT
|
||
|
ETC. FROM ANOTHER PHONE AND SWEEP UP AN DOWN TE SPECTRUM, AND YOU NOTICE THE
|
||
|
PHONE ANSWERS ITSELF SOMEWHERE IN THE SWEEP YOU PROBABLY HAVE AN INFINITY
|
||
|
TRANSMITTER ON YOUR LINE.
|
||
|
|
||
|
THE ABOVE INFORMATION TELLS NOTHING BUT TELCO TAPS AT THE CENTRAL OFFICE,
|
||
|
OR ANYWHERE ELSE ALONG THE LINE, BUT THIS INFORMATION MAY TELL YOU THAT YOUR
|
||
|
WIFE, GIRLFRIEND(BOYFRIEND), OR BUSINES ASSOCIATE MAY BE MONITORING YOUR PHONE
|
||
|
ACTIVITIES.
|
||
|
|
||
|
AN INFINITY TRANSMITTER,IS A NEAT DEVICE IT ALLOWS YOU TO CALL THE BUGGED PLACE
|
||
|
AND IT SHUTS OFF THE RINGER AND DEFEATS THE SWITCHHOOK, SO THE MOUTHPIECE NOW
|
||
|
BECOMES A ROOM BUG. IT WAS ORGINALLY SOLD FROM THE TRAVELLING BUSINESS MAN
|
||
|
TO MAKE SURE HIS WIFE WAS SAFE AT HOME NOT BEING ATTAKCED...
|
||
|
|
||
|
[ DETECTING PHONE BUGS - DR. JIMMY & MR. JIM ]
|
||
|
|
||
|
|
||
|
Downloaded From P-80 International Information Systems 304-744-2253
|