CM TELECOM AR3800
|
|||
|
|
|||
|
NOTES: This is a dual NAM unit.
|
|||
|
The ESN prefix is 153 decimal and 99 hex.
|
|||
|
This unit was only imported for a short time and is no longer
|
|||
|
supported in the USA.
|
|||
|
Several different software versions have been available and not
|
|||
|
every phone will follow these steps... Good Luck!
|
|||
|
Leave NAM 2 data at factory default If NAM 2 is not used.
|
|||
|
|
|||
|
1. Turn on power.
|
|||
|
|
|||
|
2. Lock phone by pressing FUNC 1, then 1 repeatedly until the phone
|
|||
|
displays F-LOCK, press SND.
|
|||
|
|
|||
|
3. Enter * 5 9 6 5, display will show "CONF 3800", if not try entering
|
|||
|
* 4 0 1 8 which is the master reset code.
|
|||
|
|
|||
|
4. Volume up and down keys step through the programing data. You may
|
|||
|
also directly access any step by pressing RCL NN, where NN is the
|
|||
|
step number. Some single digit options toggle by pressing STO (?).
|
|||
|
|
|||
|
5. Press SND to store each step.
|
|||
|
|
|||
|
6. Press END to complete programing and exit at any time.
|
|||
|
|
|||
|
PROGRAMING DATA:
|
|||
|
|
|||
|
STEP# #OF DIGITS/RANGE DISPLAY DESCRIPTION
|
|||
|
|
|||
|
01 10 DIGITS MINA NAM 1 AREA CODE & PHONE NUMBER
|
|||
|
02 00000 - 99999 SIDA NAM 1 SYSTEM ID
|
|||
|
03 0333 OR 0334 IPCHA NAM 1 INITIAL PAGING CHANNEL
|
|||
|
04 2 DIGITS ACOLCA NAM 1 ACCESS OVERLOAD CLASS
|
|||
|
05 2 DIGITS GIMA NAM 1 GROUP ID (10 IN USA)
|
|||
|
06 0 OR 1 L CTLA NAM 1 LOCAL USE MARK
|
|||
|
07 0 - 4 MINA NAM 1 PREFERRED SYSTEM
|
|||
|
0 = Prefer A
|
|||
|
1 = Prefer B
|
|||
|
2 = A only
|
|||
|
3 = B only
|
|||
|
4 = Home only
|
|||
|
08 UNKNOWN (LOCK CODE?)
|
|||
|
09 UNKNOWN
|
|||
|
10 10 DIGITS MINB NAM 2 AREA CODE & PHONE NUMBER
|
|||
|
11 00000 - 99999 SIDAB NAM 2 SYSTEM ID
|
|||
|
12 0333 OR 0334 IPCHB NAM 2 INITIAL PAGING CHANNEL
|
|||
|
13 2 DIGITS AOLCB NAM 2 ACCESS OVERLOAD CLASS
|
|||
|
14 2 DIGITS GIMB NAM 2 GROUP ID (10 IN USA)
|
|||
|
15 0 OR 1 L CTLB NAM 2 LOCAL USE MARK
|
|||
|
16 0 - 4 MINB NAM 2 PREFERRED SYSTEM
|
|||
|
0 = Prefer A
|
|||
|
1 = Prefer B
|
|||
|
2 = A only
|
|||
|
3 = B only
|
|||
|
4 = Home only
|
|||
|
17 0 ONLY E ADDR LEAVE AT 0
|
|||
|
18 0 OR 1 PWR SAVE AUTO POWER OFF OPTION
|
|||
|
19 00000 - 99999 ISID INHIBIT SYSTEM ID
|
|||
|
20 4 DIGITS PCAC PROGRAMING PASSWORD
|