AUDIOVOX MVX 500/50, SP95, BC65, TRANS65/420, PRO98, PRT75, CMT420
|
|||
|
|
|||
|
NOTES: These are single NAM units.
|
|||
|
The ESN prefix is 138 decimal, 8A hex (Toshiba)
|
|||
|
This unit has an excessive number of "security" features,
|
|||
|
You MUST know the lock code or the "reprograming" code and you
|
|||
|
may also need an "activation" code. Take care not to program
|
|||
|
these options unless you're sure the numbers will not be mislaid.
|
|||
|
Audiovox: 516-231-6051/213-926-7758
|
|||
|
|
|||
|
NAM programing:
|
|||
|
|
|||
|
1. With the power turned on enter N N N FUNC # 1, where NNN is the three
|
|||
|
digit lock code. The manufacturers default is 000. If a reprograming
|
|||
|
code has been entered in step 41 (see below) this code must be used in
|
|||
|
place of the three digit lock code. If "CODE ?" appears when the phone
|
|||
|
is powered up then you must enter the 7 digit "Activation Code" before
|
|||
|
entering programing mode, (see step 45).
|
|||
|
|
|||
|
2. The # key increments the step number.
|
|||
|
|
|||
|
3. The * key decrements the step number.
|
|||
|
|
|||
|
4. STO enters the data for each step.
|
|||
|
|
|||
|
5. You MAY directly access any step by pressing RCL followed by the step
|
|||
|
number.
|
|||
|
|
|||
|
6. FUNC SND completes programing.
|
|||
|
|
|||
|
7. FUNC CLR exits programing mode.
|
|||
|
|
|||
|
PROGRAMMING DATA:
|
|||
|
|
|||
|
STEP# #OF DIGITS/RANGE DESCRIPTION
|
|||
|
|
|||
|
01 10 DIGITS MIN (AREA CODE & PHONE NUMBER)
|
|||
|
02 3 DIGITS LOCK CODE
|
|||
|
03 00000 - 99999 SYSTEM ID
|
|||
|
04 00 - 15 ACCESS OVERLOAD CLASS
|
|||
|
05 00 - 15 GROUP ID (10 FOR USA)
|
|||
|
06 0 OR 1 LOCAL USE MARK
|
|||
|
07 0 OR 1 MIN MARK
|
|||
|
08 0333 OR 0334 INITIAL PAGING CHANNEL, AUTO SET
|
|||
|
09 0 OR 1 PREFERRED SYSTEM, AUTO SET
|
|||
|
10 4 DIGITS STATION CLASS MARK, AUTO SET
|
|||
|
11 8 BINARY DIGITS FUNCTION 1, SEE NOTE 1 BELOW
|
|||
|
12 8 BINARY DIGITS FUNCTION 2, SEE NOTE 2 BELOW
|
|||
|
13 00 TO 31 HOURS POWER OFF TIMER (NOT USED IN MVX 500)
|
|||
|
14 000 TO 255 SECS NO CHARGE AIR TIMER DELAY (NOT USED IN MVX 500)
|
|||
|
15 3 DIGITS CALL TIMER RESET CODE
|
|||
|
16 - 40 00000 - 99999 SIDH INHIBIT # 1 THRU # 5
|
|||
|
41 3 DIGITS NAM PROGRAMMING CODE (LEAVE BLANK, SEE ABOVE)
|
|||
|
42 - 44 NOT USED FUTURE USE
|
|||
|
45 7 DIGITS ACTIVATION CODE (LEAVE BLANK, SEE ABOVE)
|
|||
|
|
|||
|
NOTES:
|
|||
|
|
|||
|
1. This is an eight digit binary field.
|
|||
|
|
|||
|
10000000 = CALL TIMER BEEP
|
|||
|
01000000 = AUTO LOCK
|
|||
|
00100000 = AUTO SYSTEM REDIAL
|
|||
|
00010000 = CALL RESTRICTION
|
|||
|
00001000 = 32 DIGIT DIALING CAPABILITY
|
|||
|
00000100 = AUTO ANSWER
|
|||
|
00000010 = AUTO ANSWER FOR DATA
|
|||
|
00000001 = ANY KEY ANSWER
|
|||
|
11111000 = ALL OF THE ABOVE
|
|||
|
|
|||
|
|
|||
|
2. As above but options are:
|
|||
|
|
|||
|
10000000 = HANDS FREE
|
|||
|
01000000 = CONTINUOUS DTMF
|
|||
|
00100000 = REPERTORY DIALING
|
|||
|
00010000 = HORN ALERT
|
|||
|
00001000 = ALLOWS 911 CALLING WHEN UNIT IS LOCKED
|
|||
|
01101000 = ALL OF THE ABOVE
|
|||
|
|
|||
|
A/B SYSTEM SELECT:
|
|||
|
|
|||
|
FCN 0 4 DISPLAYS CURRENT MODE,
|
|||
|
FCN 0 0 = PREFERRED/NON-PREFERRED,
|
|||
|
FCN 0 1 = PREFERRED ONLY,
|
|||
|
FCN 0 2 = HOME ONLY
|
|||
|
FCN 0 3 = NON PREFERRED ONLY,
|
|||
|
|
|||
|
LOCK: Press LOCK. UNLOCK: Enter three digit code.
|