31 lines
1.2 KiB
Plaintext
31 lines
1.2 KiB
Plaintext
![]() |
HR2600.1
|
|||
|
|
|||
|
|
|||
|
AFTER HOOKING UP MY HR-2600 TO MY PK-232, I FOUND I HAD SOME PROBLEMS USING
|
|||
|
IT IN AMTOR. SINCE I LOVE TO MODIFY AND "FIX" RIGS, I GRABBED MY TEST
|
|||
|
EQUIPMENT AND SET OUT TO FIND OUT WHY THERE WAS A LONG SWITCH-OVER DELAY TIME.
|
|||
|
|
|||
|
AFTER A FEW MINUTES, I FOUND OUT THAT THE RECIEVER WAS COMMING UP OK. IT WAS
|
|||
|
THE MUTE CIRCUT THAT WAS SLOW. I FOUND TWO CAPACITORS THAT WERE RESPONSIBLE
|
|||
|
FOR THE DELAY IN THE MUTE CIRCUT.
|
|||
|
|
|||
|
TO FIX THE PROBLEM, CHANGE OUT C74 AND C99 (BOTH ARE 4.7uf @ 50VDC) WITH .01uf
|
|||
|
DISC CAPACITORS WITH A VOLTAGE RATING GREATER THAN 15VDC. THESE CAPACITORS ARE
|
|||
|
ALSO FOUND IN THE HR-2510 AS WELL. THESE SEEM TO BE C139 AND C99 IN THE HR-2510
|
|||
|
IF MY COPY IS RIGHT.
|
|||
|
|
|||
|
THESE CAPACITORS ARE LOCATED NEXT TO THE AUDIO OUTPUT IC (TDA1905) IN THE
|
|||
|
RADIO. THIS I.C. IS LISTED AS IC2 IN THE HR-2600 AND IC103 IN THE HR-2510.
|
|||
|
|
|||
|
I ALSO FOUND THE S/RF METER TO BE VERY SLOW IN MY RIG. I FIXED THIS BY CHANGING
|
|||
|
C302 ON THE CONTROL UNIT (LOCATED NEXT TO J304) TO A .01uf DISC CAPACITOR ALSO.
|
|||
|
THIS CAPACITOR IS ALSO IN THE HR-2510.
|
|||
|
|
|||
|
AFTER THESE MODIFICATIONS, I HAD NO MORE PROBLEMS MAKING ANY CONNECTS IN ANY
|
|||
|
MODE.
|
|||
|
|
|||
|
73'S AND ENJOY THE UNIDEN!
|
|||
|
|
|||
|
CRAIG/N7ETV @ WB6MQM
|
|||
|
LAS VEGAS, NEVADA. 89121
|
|||
|
|