Abbrevations for ISDN and Data Communications
|
||
|
1991/01/28, Goetz Kluge Seoul
|
||
|
cdp!anlyyao@labrea.stanford.edu
|
||
|
------------------------------------------------------------------------------
|
||
|
This list has been compiled during my work for a German semiconductor maker
|
||
|
at its Seoul branch. So you also will find some abbrevations related to that
|
||
|
products of that company. But the larger part of this collection is not rela-
|
||
|
ted to my employer. - During my work I got quite fed up with those many abbre-
|
||
|
vations which quite often are not explained in the literature. So allways when
|
||
|
one of these crossed my way, I filed it in this file. There might be some mis-
|
||
|
takes: (a) Sometimes I could not verify which of different explanaitions given
|
||
|
for an abbrevation was the right one. (b) I am Gerrrrman, so is my English.
|
||
|
------------------------------------------------------------------------------
|
||
|
1TR6 (Ger) FTZ regulation (close to CCITT Q.930/931)
|
||
|
2B1Q 2 binary data, 1 quarternary redundance
|
||
|
3PTY Three Party Service (I.254 B)
|
||
|
4B3T 4 binary data, 3 ternary redundance (MMS43)
|
||
|
5B6B 5 binary data, 6 binary redundance (code for OFT lines)
|
||
|
a/b two wire phone connection (T&R)
|
||
|
ABM Asynchronous Balanced Mode ( -> SABME)
|
||
|
ABME ABM extended
|
||
|
ACA Asynchronous Communication Adapter
|
||
|
ACD Automatic Call Distribution
|
||
|
ACFA Advanced CMOS Frame Aligner PEB2030
|
||
|
ACI Answer Controller Interface (IOM2 Monitor Command)
|
||
|
ACIA Asynchronous Communications Interface Adapter
|
||
|
ACK Acknowledge
|
||
|
ACM Address Complete Msg. (SS7: in ISUP)
|
||
|
ACSE Association Control Service Element
|
||
|
ACU Automatic Calling Unit
|
||
|
ADC American Digital Cellular
|
||
|
ADC Analog to Digital Converter
|
||
|
ADCCP Advanced Data Communication Controll Procedure
|
||
|
ADMA Advanced DMA Controller SAB82258
|
||
|
ADPCM Adaptive PCM
|
||
|
AERM Alignment Error Rate Monitor
|
||
|
AFE Analog Front End
|
||
|
AFI Authority and Format Identifier (ISO 7498)
|
||
|
AGND Analog Ground
|
||
|
AI Activate Indication (C/I channel code)
|
||
|
AI Artificial Intelligence
|
||
|
AIS Alarm Indication Signal
|
||
|
AIU AI Upstream
|
||
|
ALE Adress Latch Enable
|
||
|
AM Amplitude Modulation
|
||
|
AMC Add-on Module Connector (-> SIPB)
|
||
|
AMI Alternate Mark Inversion Code
|
||
|
ANM Answer Msg. (SS7: in ISUP)
|
||
|
ANS Answer Msg.
|
||
|
ANSI American National Standards Institute
|
||
|
AOC Advice of Charge (I.256 B)
|
||
|
AP Application (OSI Layer 7)
|
||
|
APD Avalanche Photo Diode
|
||
|
API Application Interface
|
||
|
APPC Advanced Program to Program Communication (IBM)
|
||
|
AR Activation Request (C/I channel code)
|
||
|
ARCOFI Audio Ringing Codec Filter PSB2160
|
||
|
ARCOFI-SP ARCOFI + speakerphone function PSB2165
|
||
|
ARCOS ARCOFI Coefficient Support Program
|
||
|
ARCOTI SIPB Telephone Module
|
||
|
ARD AR Downstream
|
||
|
ARL Activation Request Local loop (C/I channel code)
|
||
|
ARM Activation Request Maintenance (C/I channel code)
|
||
|
ARM Asynchronous Response Mode
|
||
|
ARN Activation Request
|
||
|
ARQ Automatic Repeat Request
|
||
|
ARU Activation Request Upstream
|
||
|
ASCC2 Advanced Serial Communication Controller SAB825??
|
||
|
ASCII American Ntl. Standard Code for Information Interchange
|
||
|
ASE Application Service Element
|
||
|
ASIC Application Specific Integrated Circuit
|
||
|
ASM Analog Subscriber Module
|
||
|
ASP ARCOFI Signal Processor
|
||
|
AT&T American Telephone & Telegraph
|
||
|
ATD Async. TDM
|
||
|
ATI Awake TI
|
||
|
ATM Analog Trunk Module
|
||
|
ATM Asynchronous Transfer Mode
|
||
|
AU Access Unit
|
||
|
AUP Access Unit Port
|
||
|
AW (Ger) termination resistor
|
||
|
AWI Awake Indication
|
||
|
B8ZS Bipolar with 8 Zeros Substitution (T1 PRI)
|
||
|
BA Basic Access
|
||
|
BAKT (Ger) Basic Access Concentrator
|
||
|
BAMX (Ger) Basic Access MUX
|
||
|
BAS Basic Activity Subset (T.62, BAS of OSI session layer)
|
||
|
BBD0/1 Binary 0s or 1s detected in B and D channels
|
||
|
BCC Block Check Character
|
||
|
BCCP Bearer CCP
|
||
|
BDS Basic Data Service
|
||
|
BEL Bell
|
||
|
BER Bit Error Rate
|
||
|
BHC Busy Hour Call
|
||
|
BIB Backward Indicator Bit (SS7)
|
||
|
BICU Bus Interface Control Unit
|
||
|
BIFIFO Bidirectional FIFO
|
||
|
BIR Bit Receiver
|
||
|
BIR Bus Interface Register
|
||
|
BISDN Broadband ISDN
|
||
|
BISYNC Binary Synchronous Communications
|
||
|
BIT Bit Transmitter
|
||
|
BITR Bit Transceiver
|
||
|
BLA Blocking Acknowledgement (SS7: in ISUP)
|
||
|
BLO Blocking (SS7: in ISUP)
|
||
|
BMU Basic Measurement Unit (DIP)
|
||
|
BOC Bell Operating Companies
|
||
|
BORSCHT Battery, Overvoltage, Ringing, Supervision, Coding, Hybrid, Testing
|
||
|
BOP Byte Oriented Protocol
|
||
|
BOS Bit Oriented Signaling
|
||
|
BPSK Binary PSK
|
||
|
BR Bit Robbing (CAS-BR)
|
||
|
BRG Baud Rate Generator
|
||
|
BS Backspace
|
||
|
BSI British Standards Institution
|
||
|
BSN Backward Sequence Number (SS7)
|
||
|
BT British Telecom
|
||
|
BVS Basic Voice Service
|
||
|
C/I Command/Indicate
|
||
|
CA Collision Avoidance (->CSMA/)
|
||
|
CAM Communication Access Method
|
||
|
CAM Computer Aided Manufacturing
|
||
|
CAM Content Adressable Memory
|
||
|
CAM Control Administration Module
|
||
|
CAN Cancel
|
||
|
CANC Cancel (I.451)
|
||
|
CAS Cannel Associated Signaling
|
||
|
CBA Change Back Acknowledgement (SS7: in MTP)
|
||
|
CBD Change Back Declaration (SS7: in MTP)
|
||
|
CBEMA Computer and Business Equipment Manufacturers' Assc.
|
||
|
CC Common Channel (CAS-CC)
|
||
|
CC Connection Confirm
|
||
|
CC Country Code (ISO 7498)
|
||
|
CC1 Call Control 1 (IOS)
|
||
|
CCA Computer Content Architecture (ISO 8637/2)
|
||
|
CCBS Completion of Call to Busy Subscribers (I.253 C)
|
||
|
CCIR Consultative Committee for Radiocomunication
|
||
|
(International Radio Consultative Committee)
|
||
|
CCIS #7 Common Channel Interoffice Signaling (Japan, SS #7 Subset)
|
||
|
CCITT Consultative Committee for Internat. Telephone and Telegraph
|
||
|
CCNC CCS Network Control
|
||
|
CCP Call Control Part
|
||
|
CCR Clock Configuration Register
|
||
|
CCR Continuity Check Request (SS7: in ISUP)
|
||
|
CCRC Corrupt CRC (IOM2 Monitor Command)
|
||
|
CCS Common Channel Signaling
|
||
|
CCU Communication Control Unit
|
||
|
CD Call Deflection (I.252 E)
|
||
|
CD Collision Detection (->CSMA/)
|
||
|
CDI Connected Line Identification (I.251 C/E)
|
||
|
CDMA Code Division MA
|
||
|
CDR Collision Detect input line
|
||
|
CE Conducted Emission (EME)
|
||
|
CE Collision Elimination (->CSMA/)
|
||
|
CEI Comparable Efficient Interconnection
|
||
|
CEN European Committee of Standards
|
||
|
CENELEC European Committee of Standards (Electrotechnics)
|
||
|
CEP Connection Endpoint
|
||
|
CEPT European Conference of Post/Telecom Administrations
|
||
|
CFI Configurable Interface (SIPB)
|
||
|
CFNR Call Forwarding No Reply (I.252 C)
|
||
|
CFP Call Forwarding Busy (I.252 B)
|
||
|
CFU Call Forwarding Unconditional (I.252 D)
|
||
|
CGB Circuit Group Blocking (SS7: in ISUP)
|
||
|
CGBA CGB Acknowledgement
|
||
|
CGM Computer Graphics Metafile (ISO DIS 8632)
|
||
|
CGU Circuit Group Unblocking (SS7: in ISUP)
|
||
|
CGUA CGU Acknowledgement
|
||
|
CIF Common Intermediate Format (for ISDN high end video)
|
||
|
CIC Circuit Identification Code
|
||
|
CID Connection Identification
|
||
|
CIP Control Interface Port
|
||
|
CIP Control Interface Port
|
||
|
CIRR C/I Receive Register
|
||
|
CIXR C/I Transmit Register
|
||
|
CK Checkbits
|
||
|
CKS Clock select bit
|
||
|
CLIP Calling Line Identification Presentation (I.251 C)
|
||
|
CLIR Calling Line Identification Restriction (I.251 D)
|
||
|
CLK Clock
|
||
|
CLS Connectless-Mode Service
|
||
|
CLT Communications Line Terminal
|
||
|
CM Connection Memory
|
||
|
CMC Call Modification Completed (SS7: in ISUP)
|
||
|
CMR Call Modification Request (SS7: in ISUP)
|
||
|
CMRJ CMR reject (SS7: in ISUP)
|
||
|
CN Connection
|
||
|
CO Central Office
|
||
|
COA Change Over Acknowledgement (SS7: in MTP)
|
||
|
COO Change Over Order (SS7: in MTP)
|
||
|
CODEC Coder/Decoder
|
||
|
COLP Connected Line Identification Presentation (I.251 E)
|
||
|
COLR Connected Line Identification Restriction (I.251 F)
|
||
|
COM/EXP PCM-Compander/Expander
|
||
|
CONF Conference Calling (I.254 A)
|
||
|
CONN Connect Msg. (I.451)
|
||
|
COP Call Offering Procedure
|
||
|
CORC Commands and Responses Definition and Compressing Program (IOS)
|
||
|
CorNet Corporate Network Protocol (ECMA and CCITT Q.930/931 oriented)
|
||
|
D-channel layer 3 protocol for private IPABX
|
||
|
COS Connection-Mode Service
|
||
|
COT Central Office Terminal (opposite to RT)
|
||
|
COT Continuity (SS7: in ISUP)
|
||
|
CPD Common Packet Data Channels
|
||
|
CPE Customer Premises Equipment
|
||
|
CPG Call Progress (SS7: in ISUP)
|
||
|
CPU Central Processing Unit SAB80188-2
|
||
|
SAB80C166
|
||
|
SAB80C5xx
|
||
|
CQM Circuit Group Query (SS7: in ISUP)
|
||
|
CQR CQM Response
|
||
|
CR Carriage Return
|
||
|
CR Control Response
|
||
|
CRC Cyclic Redundancy Check
|
||
|
CRCOK CRC ok! (C/I channel code)
|
||
|
CRED Credit Card Calling (I.256 A)
|
||
|
CREF Connection Refused
|
||
|
CS Cable Switching
|
||
|
CS Conducted Susceptibility (EMS)
|
||
|
CSMA/ Carrier Sense Multiple Access
|
||
|
CSO Cold Start Only (in EOC)
|
||
|
CSDN Circuit-Switched Data Network (T.70)
|
||
|
CSPDN Circuit-Switched Public Data Network
|
||
|
CSR Clock Shift Register
|
||
|
CST Call State or Current State or Change State (quasi SDL)
|
||
|
CT Call Transfer (I.252 A)
|
||
|
CTMC Communications Terminal Module Controller
|
||
|
CTS Clear to Send
|
||
|
CUG Closed User Group (I.255 A)
|
||
|
CW Call Waiting (I.253 A)
|
||
|
D-CTL D Channel Controller (IDEC)
|
||
|
DAC Digital to Analog Converter
|
||
|
DACOM Data Communictions Corp. of Korea (ROK)
|
||
|
DACK DMA ACK
|
||
|
DAEDR Delimitation, Alignment and Error Detection Procedure
|
||
|
in Receive Direction
|
||
|
DAML Digital Added Main Line (pair gain)
|
||
|
DAP Document Application Profile
|
||
|
DASS2 Digital Access Signaling System 2 (BT, DPNSS subset)
|
||
|
DBCS Data Bank Control System
|
||
|
DBOS Data Bank Organization System
|
||
|
DBSS Data Bank Security System
|
||
|
DBP (Ger) German Federal Post
|
||
|
DC Device Cinfirmation (C/I channel code)
|
||
|
DCn Device Control n
|
||
|
DCC Data Country Code (ISO 7498)
|
||
|
DCE Data Circuit-terminating Equipment
|
||
|
DCE Data Communications Equipment
|
||
|
DCH D-Channel Handling bit
|
||
|
DCL Data Clock (i.e. IOM2)
|
||
|
DCME Digital Circuit Multiplexing Equipment
|
||
|
DCS Data Communications Subsystem
|
||
|
DD Data Downstream (i.e. IOM2)
|
||
|
DDI Direct Dialing-In (I.251 A)
|
||
|
DDN Defense Data Network
|
||
|
DDS Dataphone Digital Service
|
||
|
DDX Digital Data Exchange
|
||
|
DEAC Deactivation (C/I channel code)
|
||
|
DECT Digital European Cellular Phone
|
||
|
DEE (Ger) data terminal
|
||
|
DEL Delete
|
||
|
DET Detatch Msg. (I.451)
|
||
|
DI Deactivation Indication (C/I channel code)
|
||
|
DIA Document Interchange Architecture
|
||
|
DIC Digital Concentrator
|
||
|
DID DI Downstream
|
||
|
DID Direct Inward Dialing
|
||
|
DIF Digital Interface
|
||
|
DIGON (Ger) digital local network (Berlin)
|
||
|
DIP Document Interchange Protocol (lower sublayer of OSI layer 6)
|
||
|
DIR Direction
|
||
|
DIS Disconnect
|
||
|
DISC Disconnect (LAP-D Command, I.451)
|
||
|
DISD Direct Inward Subscriber Access
|
||
|
DIU Deactivate Indication
|
||
|
DIU Digital Interface Unit
|
||
|
DIV (Ger) digital exchange
|
||
|
DIVF (Ger) DIV for long distance service
|
||
|
DIVO (Ger) DIV for local service
|
||
|
DL5MDA someone who collects each ISDN abbrevation crossing his way
|
||
|
DLAB Divisor Latch Access Bit
|
||
|
DLC Data Link Control
|
||
|
DLCI Data Link Connection Identifier (I.440: SAPI+TEI)
|
||
|
DLE Data Link Escape (ASCII Control)
|
||
|
DLE Delete
|
||
|
DLS Digital Line Section
|
||
|
DLUC Digital Line Unit Control
|
||
|
DM Disconnected Mode (LAP-D Response)
|
||
|
DMA Direct Memory Access
|
||
|
DNHR Dynamic Nonhierarchical Routing
|
||
|
DNIC Data Network Identification Code (ISO 7498)
|
||
|
DOD (USA) Dept. of Defense
|
||
|
DPC Destination Point Code (SS7)
|
||
|
DPCM Differential PCM
|
||
|
DPLL Digital Phase Locked Loop
|
||
|
DPNSS Digital Private Network Signaling System (BT)
|
||
|
DPSK Differential Phase Shift Keying
|
||
|
DR Deactivate Request (C/I channel code)
|
||
|
DRAM Dynamic RAM
|
||
|
DRCS Dynamically Redefinable Character Sets
|
||
|
DR Deactivation Request
|
||
|
DRE Direction
|
||
|
DSC Digital Subscriber Controller Am79C30A
|
||
|
DSGLA (Ger) DLS
|
||
|
DSI Digital Speech Interpolation
|
||
|
DSM Digital Switching Module
|
||
|
DSMX (Ger) digital signal multiplexer
|
||
|
DSP Digital Signal Processing
|
||
|
DSP Domain Specific Part (ISO 7498)
|
||
|
DSR Data Set Ready
|
||
|
DSU Data Servicing Unit
|
||
|
DT Data Through (C/I channel code in test mode)
|
||
|
DT1 Data Form Class 1
|
||
|
DTAM Document Transfer Access and Manipulation
|
||
|
DTC Digital Telephone Controller (ARCOFI + IBC + ICC)
|
||
|
DTE Data Terminal Equipment
|
||
|
DTM Digital Trunk Module
|
||
|
DTMF Dual Tone Multi Frequency (Dial) PSB8593
|
||
|
DTR Data Terminal Ready
|
||
|
DU Data Upstream (i.e. IOM2)
|
||
|
DU Deactivation Request Upstream (C/I channel code)
|
||
|
DUP Data User Part
|
||
|
DVA (Ger) data processing equipment
|
||
|
DYRECT SIDES Dynamic Real Time Communication Tester
|
||
|
(in SITEST, tests IOS on Board)
|
||
|
EA Expedited Data Acknowledgement (SS7: in SCCP)
|
||
|
EA Extended Adress
|
||
|
EBCDIC Extended Binary Coded Decimal Interchange Code
|
||
|
EC Echo Canceller
|
||
|
EC European Community
|
||
|
ECL Emitter Coupled Logic
|
||
|
ECMA European Computer Manufactueres Association
|
||
|
EDI Electronic Data Interchange
|
||
|
EEPROM Electrically Erasable Programmable Read Only Memory
|
||
|
EIn Error Indication n (C/I channel code)
|
||
|
EM Encription Module
|
||
|
EM End of Medium (ASCII Control)
|
||
|
EMC Electromagnetic Compatibility
|
||
|
EME Electromagnetic Emission
|
||
|
EMI Electromagnetic Interference
|
||
|
EMS Electromagnetic Susceptibility
|
||
|
EMV EMC (German)
|
||
|
ENQ Enquiry
|
||
|
EO End Office
|
||
|
EOC Embedded Operation Channel
|
||
|
EOM End of Message
|
||
|
EP Expedited Data (SS7: in SCCP)
|
||
|
EPIC Extended PIC PEB2055
|
||
|
EQ Equalizer
|
||
|
ERC Error Control (IOS)
|
||
|
ESC Enhanced Speech Circuit PSB4505/6
|
||
|
ESC Escape (ASCII Control)
|
||
|
ESCC2 Extended high level Serial Communication Controller SAB82532
|
||
|
(2 channel multi protocol controller)
|
||
|
ESCC8 like ESCC2, but 8 channels SAB82538
|
||
|
ESF Extended Super Frame
|
||
|
EST established
|
||
|
ET Exchange Termination
|
||
|
ETB End of Transmission Block
|
||
|
ETRI Electronics and Telecommunications
|
||
|
Research Institute (ROK)
|
||
|
ETX End of Text
|
||
|
EVST (Ger) end exchange
|
||
|
EWSD (Ger) electronic dialing system (Digital)
|
||
|
FA Frame Aligner
|
||
|
FAA Facility Accepted (SS7: in ISUP)
|
||
|
FAC Facility
|
||
|
FACD Facility Changed Msg.
|
||
|
FAR Facility Request (SS7: in ISUP)
|
||
|
FAS Frame Alignment Signal
|
||
|
FAX Faximile
|
||
|
FC Feature Control
|
||
|
FC Frame Control
|
||
|
FCC Federal Communications Comission (USA)
|
||
|
FCS Frame Check Sequence
|
||
|
FDDI Fiber Distributed Data Interface (X3T9.5)
|
||
|
FDM Frequency Division Multiplex
|
||
|
FDMA FDM Access
|
||
|
FEBE Far End Block Error (IOM2 Monitor Message)
|
||
|
FEC Forward Error Correction
|
||
|
FECC Front End Communication Computer
|
||
|
FF Form Feed
|
||
|
FIB Forward Indication Bit (SS7)
|
||
|
FIFO First In First Out (storage)
|
||
|
FIN Facility Information Msg.
|
||
|
FISU Fill In Signal Unit (SS7)
|
||
|
FJ Frame Jump (C/I channel code)
|
||
|
FM Frequency Modulation
|
||
|
FMM Finite Message Machine
|
||
|
FNBE Far and Near end Block Error (IOM2 Monitor Message)
|
||
|
FOT Forward Transfer (SS7: in ISUP)
|
||
|
FP Functional Protocol
|
||
|
FPC Frequency Comparison Pilots
|
||
|
FPS Fast Packet Switching
|
||
|
FRAC Frame Aligner Circuit PEB2030
|
||
|
FRJ Facility Rejected Msg. (SS7: in ISUP)
|
||
|
FRMR Frame Reject (LAP-D Response)
|
||
|
FRQ Facility Request Message
|
||
|
FS File Separator
|
||
|
FSC Frame Synchronization Clock (i.e. IOM2)
|
||
|
FSN Forward Sequence Number
|
||
|
FTP File Transfer Protocol (DOD)
|
||
|
FTZ (Ger) Central Telecom Technical Office (of DBP)
|
||
|
GAP (EC) Group of Analysis and Provision (for ONP)
|
||
|
GB Great Britain
|
||
|
GC Group Card
|
||
|
GCI General Circuit Interface (IOM/U(k0)-Interface)
|
||
|
GCR General Configuration Register
|
||
|
Ger German
|
||
|
GP Group Processor
|
||
|
GPPC General Purpose Power Controller PSB2121
|
||
|
GPS Global Positioning System
|
||
|
GRA GRS Acknowledgement
|
||
|
GRS Circuit Group Reset (SS7: in ISUP)
|
||
|
GS Group Separator
|
||
|
GTEI Global TEI
|
||
|
GWY Gateway
|
||
|
H Hold state (in EOC)
|
||
|
H- High-
|
||
|
HAC Hands-Free Add-On Circuit (for speakerphone) PSB45030
|
||
|
HDB3 High-Density Bipolar 3 (CEPT PRI)
|
||
|
HDLC High Level DLC
|
||
|
HDTV High Definition TV
|
||
|
HFR Hardwara Failure Rate
|
||
|
HI High Impedance (C/I channel code)
|
||
|
HI Highway Interrupt
|
||
|
HL IT Siemens Semiconductors (HL), Info Technics (IT)
|
||
|
HOLD Call Hold (I.253 B)
|
||
|
HSCC High Level Serial Communication Controller SAB82520
|
||
|
HSCX extended HSCC SAB82525
|
||
|
HT Horizontal Tabulator
|
||
|
HTI Highway Transfer Interrupt
|
||
|
HU High-Usage trunk
|
||
|
HW PCM Highway
|
||
|
I Information (LAP-D Command)
|
||
|
I- Information (numbered I-Frames)
|
||
|
I/O Input/Output
|
||
|
IAM Initial Address Msg. (SS7: in ISUP)
|
||
|
IBC ISDN Burst Transceiver Circuit PEB2095
|
||
|
IBFN (Ger) integrated high bandwith long distance network
|
||
|
IC Incoming Call (X.25)
|
||
|
ICOM (Taiwan) Integrated Communication
|
||
|
ICAO International Civil Aviation Organization
|
||
|
ICC ISDN Communications Controller PEB2070
|
||
|
IDA (GB) Interated Digital Access (B64+B8+D8)
|
||
|
IDEC ISDN D-channel Exchange Controller PEB2075
|
||
|
IDI Initial Domain Identifier (ISO 7498)
|
||
|
IDN (Ger) integrated data network
|
||
|
IDPC Integrated Data Protocol Controller SAB79C401
|
||
|
IEC International Electrotechnical Comission
|
||
|
IEC ISDN Echo Cancellation Circuit
|
||
|
IEC-T IEC for 4B3T PEB2090
|
||
|
IEC-Q1 IEC for 2B1Q PEB2091
|
||
|
IEC-Q2 IEC-Q specially for LT and NT1 (without microprocessor) PEB2092
|
||
|
IEC-Q3 IEC-Q with parallel processor interface (i.e. for DAML) PEB2093
|
||
|
IEC-P (old name of IEC-Q3)
|
||
|
IEPC ISDN Exchange Power Controller PEB2025
|
||
|
IFRB International Frecuency Registration Board
|
||
|
IFS (Switzerland) integrated telecom service
|
||
|
IGS Idenitfy Graphic Subrepertoire (Teletex)
|
||
|
IKZ (Ger) pulse dial
|
||
|
ILC ISDN Link Controller
|
||
|
IM Input MUX
|
||
|
IMC IOS Mailbox Control
|
||
|
IMMU IOS Memory Management Unit
|
||
|
IMP Interpersonal Messaging Protocol (X.420: P2)
|
||
|
INF Information (SS7: in ISUP)
|
||
|
INR Information Request (SS7: in ISUP)
|
||
|
INS (Japan) Information Network System (B64+B16+D8)
|
||
|
INT Interrupt (i.e. C/I channel code)
|
||
|
IOC Integrated Optical Circuit
|
||
|
IOM ISDN-Oriented Modular (Architecture and Interfaces)
|
||
|
IOM2 extended IOM
|
||
|
IOS ISDN Operational Software SIPB6013
|
||
|
IP Intermediate Point
|
||
|
IP Internet Protocol (TCP/IP, DOD)
|
||
|
IPABX ISDN PABX
|
||
|
IPAC ISDN PC Adapter Circuit PEB21??
|
||
|
IPAT ISDN Primary Access Transceiver PEB2235
|
||
|
IPB SIPB
|
||
|
IPBC IOM2 PBC (old name for EPIC)
|
||
|
IPC Interprocess Communication
|
||
|
IPCS IOS Process Control System
|
||
|
IPP IOS Protocol Part
|
||
|
IRPC ISDN Remote Power Control PSB2120
|
||
|
ISAC-P ISDN Subscriber Access Controller (S Bus, PABX, U) PEB20950
|
||
|
ISAC-S ISDN Subscriber Access Controller (S Interface ICC+SBC) PEB2085
|
||
|
ISDN Integrated Services Digital Network
|
||
|
ISM ISDN Switching Module
|
||
|
ISO International Organization for Standardization
|
||
|
ISP Intermediate Service Part
|
||
|
ISPC International Signaling Point Code (SS7)
|
||
|
ISPBX Integrated Systems PBX
|
||
|
ISSS ISDN Supporting System
|
||
|
ISTA Interrupt Status Register
|
||
|
ISUP ISDN User Part (SS7: Q.76X)
|
||
|
IT Inactivity Test (SS7: in SCCP)
|
||
|
ITAC ISDN Terminal Adaptor Circuit PEB2110
|
||
|
ITSTC Information Technology Steering Committee
|
||
|
(CEN, CENELEC, CEPT)
|
||
|
ITU International Telecommunication Union
|
||
|
IVD Integrated Voice Data
|
||
|
IWF Interworking Facility (Gateway)
|
||
|
IWU Interworking Unit (Gateway)
|
||
|
JDC Japan Digital Cellular
|
||
|
KTA Korea Telecommunication Authority (ROK)
|
||
|
KVST (Ger) node exchange
|
||
|
KZU (Ger) signaling converter
|
||
|
L3-ERC Layer 3 Error Control (IOS)
|
||
|
L3M Layer 3 Mgr. (IOS)
|
||
|
LAN Local Area Network
|
||
|
LAPB (LAP-B) Link Access Procedure of Balanced Mode
|
||
|
LAPD (LAP-D) Link Access Procedure of D-Channels
|
||
|
LAPM (LAP-M) Link Access Protocol for Modems
|
||
|
LAPX LAPB extended (T.71, for half duplex teleservice)
|
||
|
LATA Local Access and Transport Areas
|
||
|
LBBD Loopback B1, B2 and D channel request
|
||
|
(Command in IOM2 Monitor and EOC)
|
||
|
LBn Loopback channel Bn request
|
||
|
(Command in IOM2 Monitor and EOC)
|
||
|
LC Line Card
|
||
|
LCN Logical Channel Number
|
||
|
LCS7 Link Controller for Signaling System No.7 PEB3040
|
||
|
(layer 2, CCITT Q.703, upgraded HSCX, pin compatible)
|
||
|
LE Local Exchange (contains D-CTL)
|
||
|
LF Line Feed
|
||
|
LH Line Hunting (I.252 F)
|
||
|
LI Length Indicator (SS7)
|
||
|
LIU Line Interface Unit
|
||
|
LL Logical Link
|
||
|
LLC Low Level Controller SIPx6100
|
||
|
LLD Low Level Device Drivers (IOS)
|
||
|
LLID LL Identifier
|
||
|
LLL Last Look Logic
|
||
|
LLP Link Layer Protocol (LAPD)
|
||
|
LNA Low Noise Amplifier
|
||
|
LOF Loss of Frame
|
||
|
LRC Longitudinal Redundancy Check
|
||
|
LRN Local Reference Number
|
||
|
LSEC Loss of SEC (C/I channel code)
|
||
|
LSL Loss of Signal Level (C/I channel code)
|
||
|
LSSU Link State Signal Unit (SS7)
|
||
|
LSU Loss of Signal level of U interface (C/I channel code)
|
||
|
LSUE LSU Error condition (C/I channel code)
|
||
|
LT Line Termination
|
||
|
LT-S LT on S bus
|
||
|
LT-T LT on T interface
|
||
|
LTD LT Disable (C/I channel code)
|
||
|
LTG Line Trunk Group
|
||
|
LTU Line Trunk Unit
|
||
|
LTUC LTU Control
|
||
|
LU 6.2 protocol for APPC
|
||
|
LWL (Ger) OFT
|
||
|
MA Multiple Access (Primary)
|
||
|
MAP Manufacturing Automation Protocol
|
||
|
MAP Mobile Application Part
|
||
|
MCI Malicious Call Identification (I.251 G)
|
||
|
MDF Main Distribution Frame
|
||
|
MF Mainboard Firmware (IOS)
|
||
|
MF Multi Frame
|
||
|
MFJ Modification of Final Judgement
|
||
|
MFC Multiple Frame operation Control (IOS)
|
||
|
MH Modified Huffman code (FAX)
|
||
|
MHS Message Handling Service
|
||
|
MIP Microprocessor Interface Port
|
||
|
MIPS Million Instructions per Second
|
||
|
MML Man Machine Language
|
||
|
MMS43 Modified Monitoring State 43 Code (4B3T)
|
||
|
MMU Memory Management Unit (IOS)
|
||
|
MNP Microcom Networking Protocol
|
||
|
MOC Ministery of Communication
|
||
|
MOD Ministery of Defense
|
||
|
MON Monitor Channel (i.e. IOM2)
|
||
|
MP Microprocessor
|
||
|
MPC MP Command
|
||
|
MPDU Message Protocpl Data Units (X.411)
|
||
|
MR Modified READ (Relative element address designate, FAX)
|
||
|
MR Monitor Read (flow control bit in IOM2)
|
||
|
MS Menue Software (SIPB.EXE)
|
||
|
Msg Message
|
||
|
MSN Multiple Subscriber Number (I.251 B)
|
||
|
MSU Msg. Signal Unit (SS7)
|
||
|
MTA Message Transfer Agent (X.400)
|
||
|
MTAE Message Transfer Agent Entity (X.400)
|
||
|
MTP Message Transfer Part (SS7: Q.701-Q.710)
|
||
|
MTP Message Transfer Protocol (X.411: P1)
|
||
|
MTS Memory Time Swich PEB2040
|
||
|
MTSC MTS CMOS (512 incoming channels) PEB2045
|
||
|
MTSL MTS Large (1024 incoming channels) PEB2047
|
||
|
MTSS MTS Small (256 incoming channels) PEB2046
|
||
|
MUNICH Multichannel (32) Network Interface Controller SAB20320
|
||
|
MUSAC Multipoint Switching and Conferencing Unit PEB2245
|
||
|
MUX Multiplexer
|
||
|
MW (Ger) service word
|
||
|
MX Monitor Transmit (flow control bit in IOM2)
|
||
|
N(R) (NR) Receive Sequence Number
|
||
|
N(S) (NS) Transmit Sequence Number
|
||
|
NAK Negative Acknowledge
|
||
|
NB Narrow Band
|
||
|
NCC Notify Corrupted CRC (in EOC)
|
||
|
NCU Network Control Unit
|
||
|
NCP Network Control Point (in a SDN)
|
||
|
NCTE Network Channel Terminating Equipment (FCC: NT1)
|
||
|
NDC National Destination Code (i.e. area code)
|
||
|
NDU Network Data Unit
|
||
|
NEBE Near End Block Error (IOM2 Monitor Message)
|
||
|
NET (EC) European standards of telecommunication
|
||
|
NF (Ger) low frequency
|
||
|
NFS Network File System
|
||
|
NFT Network File Transfer
|
||
|
NLP Network Layer Protocol
|
||
|
NORM return to Normal (IOM2 Monitor Command/Message)
|
||
|
NRM Normal Response Mode (HSCX)
|
||
|
NRZ Non Return to Zero
|
||
|
NRZC NRZ Change
|
||
|
NRZI NRZ Inverted
|
||
|
NRZM NRZ Mark
|
||
|
NSP Network Service Part (SS7: SCCP+MTP)
|
||
|
NStA (Ger) PBX
|
||
|
NT Network Termination
|
||
|
NT1 NT serving Layer 1 (NCTE, network interface of NT,
|
||
|
between reference points T and U)
|
||
|
NT2 NT serving Layer 1 to 3 (subscriber interface of NT,
|
||
|
between reference points S and T)
|
||
|
NT/S NT Simulator SIPB7020
|
||
|
NTM NT Test Mode (IOM2 Monitor Message)
|
||
|
NUC Nailed-up Connection
|
||
|
NUA (international) Network User Address
|
||
|
NUI Network User Identification
|
||
|
NUL Null
|
||
|
NUP National User Part
|
||
|
NVM Non Volatile Memory (EEPROM)
|
||
|
NWI Network Interface
|
||
|
OA&M Operations, Administration & Maintenance (SS7: Q.79X)
|
||
|
OC Office Communication
|
||
|
OCP Origination Point Code (SS7)
|
||
|
ODA Office Document Architecture
|
||
|
OEIC Optoelectronic Integrated Circiut
|
||
|
OFT Optical Fiber Tube
|
||
|
OM Output MUX
|
||
|
OMAP Operations and Maintanance Application Part
|
||
|
OMC Operating and Maintainance center
|
||
|
ONA Open Network Architecture (FCC: Computer Inquiry III)
|
||
|
ONP Open Network Provision
|
||
|
OPC Originating Point Code
|
||
|
OPDU Operations Protocol Data Unit (X.411: P3)
|
||
|
OSI Open Systems Interconnection
|
||
|
OVST (Ger) local exchange
|
||
|
OWG Optical Wave Guide
|
||
|
P/F Poll/Final Bit
|
||
|
PABX Private Automatic Branch Exchange
|
||
|
PAD Packet Assembly/Disassembly Device
|
||
|
PAM Pass Along Method (SS7: in ISUP)
|
||
|
PAM Primary Access Method
|
||
|
PAS Protocol Architecture Specification for IOS (PCT)
|
||
|
PBC Peripheral Board Controller PEB2050/51
|
||
|
PBX Private Branch Exchange
|
||
|
PC Power Controller
|
||
|
PC Primary Center
|
||
|
PCL PCM data Clock
|
||
|
PCM Pulse Code Modulation
|
||
|
PCN Personal Communication Network (UK, mobile comm.)
|
||
|
PCR Preventive Cyclic Retransmission (SS7: in MTP)
|
||
|
PCSN Public Circuit Switched Network (?)
|
||
|
PCT IOS Program Coding Tools (SDL oriented) SIPO6021
|
||
|
PDC Primary Digital Carrier
|
||
|
PDM Power Down Mode
|
||
|
PDU Protocol Data Unit (X.400)
|
||
|
PDN Public Data Network
|
||
|
PFOFF Power Feed OFF (C/I channel code)
|
||
|
PFS Page Format Selection (Teletex)
|
||
|
PFS PCM Frame Synchronisation Signal
|
||
|
PH Packet Handler
|
||
|
PH- Physical-
|
||
|
PIC PCM Interface Controller PEB2052
|
||
|
PIOCS Physical I/O System
|
||
|
PIP PCM Interface Port
|
||
|
PIU PCM Interface Unit
|
||
|
PKT Packet
|
||
|
PLC Physical Link Control (IOS)
|
||
|
PLD Partial Line Down (Teletex)
|
||
|
PLIC PCM Line Interface
|
||
|
PLL Phase Locked Loop
|
||
|
PLU Partial Line Up (Teletex)
|
||
|
PM Phase Modulation
|
||
|
PN Pseudo Noise (Code)
|
||
|
PNP Private Numbering Plan (I.255 B)
|
||
|
PPU Power Providing Unit
|
||
|
PRI Primary Rate Interface
|
||
|
PS Packet Switching
|
||
|
PSDN Packed-Switched Data Network (T.70)
|
||
|
PSF Packet Switching Facility
|
||
|
PSK Phase Shift Keying
|
||
|
PSL IOS Protocol Source Library
|
||
|
PSPDN Packed-Switched Public Data Network
|
||
|
PSR Phase Shift Register
|
||
|
PST SIDES Protocol Software Development
|
||
|
PSTN Public Switched Telephone Network (T.70)
|
||
|
PU Power Up (C/I channel code)
|
||
|
PUM PU Mode
|
||
|
PVC Permanent Virtual Circuit
|
||
|
Q-CIF Quarter CIF (for ISDN low end video)
|
||
|
QSC Quad S Interface Circuit PEB2084
|
||
|
QTAM Queued Telecom Access Method
|
||
|
RA Rate Adaption
|
||
|
RAD Receive Adress
|
||
|
RAM Random Access Memory
|
||
|
RBEF Read Block Error counter for Far end (IOM2 Monitor Command)
|
||
|
RBEN Read Block Error counter for Near end (IOM2 Monitor Command)
|
||
|
RBOC Regional BOC
|
||
|
RC Regional Center
|
||
|
RCC Request Corrupted CRC (in EOC)
|
||
|
RCL Route Clock
|
||
|
RCI Read Controller Interface (IOM2 Monitor Command)
|
||
|
RCP Remote Copy
|
||
|
RCRE Receive Corrected Reference Equivalent
|
||
|
RCU Repeater Control Unit (i.e. ASIC between two IEC-Q2s)
|
||
|
RDS Running Digital Sum
|
||
|
RDY Resynchonisation indication after loss of framing
|
||
|
(C/I channel code)
|
||
|
RE Radiated Emission (EME)
|
||
|
REC Receiver
|
||
|
REJ Reject (LAP-D Command/Response, I.451)
|
||
|
REL Release (I.451)
|
||
|
RES Reset (C/I channel code)
|
||
|
RES Resume (I.451)
|
||
|
RES1 Reset receiver (C/I channel code)
|
||
|
REMSH Remote Shell
|
||
|
REV Reverse Charging (I.256 C)
|
||
|
RFI Radio Frequency Interference
|
||
|
RID Read Identification (IOM2 Monitor Command)
|
||
|
RKW (Ger PCM30) FAS
|
||
|
RL Return Loss
|
||
|
RLC Release Complete Msg. (SS7: in SCCP)
|
||
|
RLOGIN Remote Login
|
||
|
RLSD Released Msg. (SS7: in SCCP)
|
||
|
RNR Receive Not Ready (LAP-D Command/Response)
|
||
|
ROK Republic of Korea
|
||
|
ROSE Remote Operation Service Element (TCAP subset)
|
||
|
RP Repeater
|
||
|
RPFC Read Power Feed Current value (IOM2 Monitor Command)
|
||
|
RPOA Recognized Private Operating Agency
|
||
|
RR Receive Ready (LAP-D Command/Response)
|
||
|
RS Radiated Susceptibiltiy (EMS)
|
||
|
RS Record Separator (ASCII Control)
|
||
|
RS Reset
|
||
|
RSC Reset Confirm (SS7: in SCCP and ISUP)
|
||
|
RSY Resynchronizing (C/I channel code)
|
||
|
RSYD RSY Downstream
|
||
|
RSYU RSY Upstream
|
||
|
RT Remote Terminal (opposite to COT)
|
||
|
RTB Retransmission Buffer
|
||
|
RTCA Radio Technical Commission of Aeronautics
|
||
|
RTN Return to Normal (in EOC)
|
||
|
RTS Request to Send
|
||
|
RTSE Reliable Transfer Service Element
|
||
|
RxSD Receive Serial Data
|
||
|
RZ Return to Zero (-> NRZ)
|
||
|
S- Supervisory (S-Frames)
|
||
|
SAA System Applications Architecture (for PS/2)
|
||
|
SABME Set Asynchronous Balanced Mode (ABM) Extended (LAP-D Command)
|
||
|
SAC Service Access Connector (-> SIPB)
|
||
|
SAI S Activity Indicator (in EOC)
|
||
|
SAM Subsequent Address Msg. (SS7: in ISUP)
|
||
|
SANE Signaling Area/Network Code (SS7)
|
||
|
SAP Service Access Point
|
||
|
SAPI Service Access Point Identifier
|
||
|
SAW Surface Acoustic Wafe (Filter) B5534
|
||
|
SBC S Bus Interface Circuit PEB2080
|
||
|
SBCX SBC extended PEB2081
|
||
|
SBUC S Bus Connector
|
||
|
SC Sectional Center
|
||
|
SCCP Signaling CCP (SS7: Q.71X)
|
||
|
SCL Station Clock
|
||
|
SCLK Slave CLK
|
||
|
SCM Scramble Coder Multiplexer
|
||
|
SCP Service Control Point
|
||
|
SCR Signaling Configuration Register
|
||
|
SCRC Send Corrected Reference Equivalent
|
||
|
SD Slip Detected
|
||
|
SDE Submission/Delivery Entity (X.400)
|
||
|
SDL Specification and Description Language
|
||
|
SDLC Synchronous DLC
|
||
|
SDM Space Division Multiplex
|
||
|
SDN Software Defined Network
|
||
|
SDP Submission and Delivery Protocol (X.411)
|
||
|
SDT Software Development Tools
|
||
|
SEC Signal level behind the Echo Canceller (C/I channel code)
|
||
|
SEL digital Selector (in TMS)
|
||
|
SF Service Field
|
||
|
SF Status Field (SS7)
|
||
|
SFB Set next FEBE to zero
|
||
|
SFD Superframe Detected (C/I channel code)
|
||
|
SGC Switching Group Control
|
||
|
SGH Select Graphic Rendition (Teletex)
|
||
|
SHI Select Horizontal Spacing (Teletex)
|
||
|
SI Sequenced Information
|
||
|
SI Service Indicator
|
||
|
SI Shift In (ASCII Control)
|
||
|
SICOFI Signal Processing Codec Filter PEB2060
|
||
|
SICOFI2 2 channel SICOFI PEB2260
|
||
|
SIDES Siemens ISDN Software Development and Evaluation System
|
||
|
SIF Signaling Information Field (SS7)
|
||
|
SIG Signaling equipment (in a trunk)
|
||
|
SIGS Signaling Strobe
|
||
|
SIN Status Indication Normal Alignment
|
||
|
SIO Service Information Octet (SS7)
|
||
|
SIP Serial Interface Port
|
||
|
SIPB Siemens ISDN PC User Board
|
||
|
SIPB 5XXX SIPB Modules
|
||
|
SIPB 7XXX SIPB Configurations
|
||
|
SIPMOS Siemens P MOS BUZ...
|
||
|
BSS...
|
||
|
BSP...
|
||
|
SIPO 6XXX Siemens ISDN PC Software Object Code
|
||
|
SIPS 6XXX Siemens ISDN PC Software Source Code
|
||
|
SITAC Siemens Isolated Thyristor AC
|
||
|
SITEST Siemens ISDN Protocol Software Test Tools SIPO6022
|
||
|
SIU Subscriber Line Interface Unit
|
||
|
SL Subscriber Line
|
||
|
SLA Subscriber Line Adress
|
||
|
SLC Signaling Link Code (SS7)
|
||
|
SLD Subscriber Line Data (Bus)
|
||
|
SLIC Subscriber Line Interface Circuit
|
||
|
SLM Subscriber Line Module
|
||
|
SLMA SLM Analog
|
||
|
SLMD SLM Digital
|
||
|
SLS Signaling Link Selection (SS7)
|
||
|
SM Service Module
|
||
|
SM Speech Memory
|
||
|
SMD Surface Mounted Device
|
||
|
SMF Sub Multi Frame
|
||
|
SMS Service Management System
|
||
|
SMTP Simple Mail Transfer Protocol
|
||
|
SNA System Network Architecture (IBM)
|
||
|
SO Shift Out
|
||
|
SOH Start of Header
|
||
|
SP (Ger) storage
|
||
|
SP Signal Point (Switching Office in SS7)
|
||
|
SP Stimulus Protocol
|
||
|
SPC Signaling Poiny Code (SS7)
|
||
|
SPC Stored Program Controlled
|
||
|
SPCR Serial Port Control Register
|
||
|
SQD Signal Quality Detector
|
||
|
SRAM Static RAM
|
||
|
SS7 Signaling System #7 (CCITT)
|
||
|
SSC Standard Speech Circuit PSB4500/-1
|
||
|
SSF Sub Service Field
|
||
|
SSI Serial Signal Interface
|
||
|
SSN Subsystem Number
|
||
|
SSP Send Single Pulses (C/I channel code for test mode)
|
||
|
SSP Service Switching Point
|
||
|
ST Self Test request NT (IOM2 Monitor Message)
|
||
|
ST Subscriber Terminal
|
||
|
STP Self Test Pass (IOM2 Monitor Message)
|
||
|
STATMUX Statistical Multiplexer
|
||
|
STCR Syncron Transfer Control Register
|
||
|
STEP SIDES Static Test of IOS and MF on board (in SITEST)
|
||
|
STM Synchronous Transfer Mode
|
||
|
STORY Screening Tool for Report Files (IOS)
|
||
|
STP Signal Transfer Point (SS7)
|
||
|
STS Space-Time-Space switch (TMS-TSI-TMS)
|
||
|
STS Steered Tenant Service
|
||
|
STS 2060 SICOFI software
|
||
|
STU 2000 stand alone ISDN user board
|
||
|
STU 2040 stand alone MTS user board
|
||
|
STU 2050 stand alone PBC user board
|
||
|
STU 2060 stand alone SICOF user board
|
||
|
STUDIALO PC Software for STU 2XXX
|
||
|
STX Start of Test
|
||
|
SU Signaling Unit
|
||
|
SUB Sub-addressing (I.251)
|
||
|
SUB Substitute Character (Teletex)
|
||
|
SUERM SU Error Rate Monitor
|
||
|
SUS Suspend (SS7: in ISUP)
|
||
|
SUSP Suspend (I.451)
|
||
|
SVC Switched Virtual Circuit
|
||
|
SVM Service Module
|
||
|
SVP Surge Voltage Protector various
|
||
|
SVS Select Vertical Spacing (Teletex)
|
||
|
SWFC Sliding-Window Flow Control
|
||
|
SYN Synchronous Idle
|
||
|
SYP Synchronisation Pulse
|
||
|
T double wire pair
|
||
|
T- Transportfunction-
|
||
|
T&R two wire phone connection
|
||
|
TA Terminal Adaption
|
||
|
TAC TEI Assignment Control (IOS)
|
||
|
TAC Technical Assistance Center
|
||
|
TAP Teletex Access Protocol (X.430: P5)
|
||
|
TC Toll Center
|
||
|
TC Transaction Capabilities
|
||
|
TCAP Transaction Capabilities Application Part
|
||
|
TCM Time Compression Multiplexing
|
||
|
(also "ping pong" or "burst" transmission, used in IBC)
|
||
|
TCP Transport Control Protocol (DOD, IP)
|
||
|
TCU Timing Control Unit
|
||
|
TDC Telex Destination Code (ISO 7498)
|
||
|
TDM Time Division Multiplex
|
||
|
TDMA TDM Access
|
||
|
TE Terminal Equipment
|
||
|
TE Transit Exchange (contains PSF)
|
||
|
TEI Terminal Endpoint Identifier
|
||
|
TELEKOM (Ger) telecom division of DBP
|
||
|
TELEX Teleprinter Exchange
|
||
|
TELNET virtual terminal protocol
|
||
|
TF (Ger) carrier frequency
|
||
|
THL Trans Hybrid Loss
|
||
|
TI Test Indication
|
||
|
TIC Telecom IC (IOM-Bus)
|
||
|
TIM Timing
|
||
|
TKO (Ger) telecom regulations
|
||
|
TM Testmode
|
||
|
TM Trasfer Modus
|
||
|
TM1 Terminal 1 (IOS)
|
||
|
TMA Trunk Module Analog
|
||
|
TMD Trunk Module Digital
|
||
|
TMS Time-Multiplexed Switching
|
||
|
TMX Trunk Module with X-interface
|
||
|
TN Tone (C/I channel code: wake up signal)
|
||
|
TNC Terminal Node Controller
|
||
|
TOP Technical Office Protocol
|
||
|
TOPQ Top of Queue (quasi SDL)
|
||
|
TRI Tone Ringer PSB652x
|
||
|
TS Time Slot
|
||
|
TSA Time Slot Assignment
|
||
|
TSC Tristate Control
|
||
|
TSI Time-Slot Interchange
|
||
|
TST Time-Space-Time switch (TSI-TMS-TSI)
|
||
|
TUP Telephone User Part (SS7: Q.72X)
|
||
|
TWX Teletype Writer Exchange
|
||
|
TxSD Transmit Serial Data
|
||
|
U single wire pair
|
||
|
U- Unnumbered (U-Frames)
|
||
|
U(k0) (Ger) U0 echo cancellation Interface
|
||
|
U(p0) (Ger) U0 burst mode Interface
|
||
|
UA Unnumbered ACK (LAP-D Response)
|
||
|
UA User Agent (X.400)
|
||
|
UAE User Application Entity or User Agent Entity (X.400)
|
||
|
UAI U Activation Indication (C/I channel code)
|
||
|
UBA Unblocking Acknowledgement
|
||
|
UBL Unblocling (SS7: in ISUP)
|
||
|
UDLC Universal DLC
|
||
|
UDT Unidata (SS7: in SCCP)
|
||
|
UDTS Unidata Servive (SS7: in SCCP)
|
||
|
UDP User Datagram Protocol
|
||
|
UI Unnumbered Information (LAP-D Command)
|
||
|
UIC U-Interface Unit
|
||
|
ULCU User Level Control/Command Unit
|
||
|
UOA U Interface Only Activation (in EOC)
|
||
|
UP User Part
|
||
|
US Unit Separator
|
||
|
USART Universal Synchrounous/Asynchrounous Receiver/Transmitter
|
||
|
USR User-to-User Information (SS7: in ISUP)
|
||
|
UTC Unable to Comply Ack (in EOC)
|
||
|
UTC Unacknowledged (Unnumbered) Information Transfer Control (IOS)
|
||
|
UTM Universal Transaction Monitor
|
||
|
UUCP Unix-System to Unix-System Copy
|
||
|
UUS User-to-User Signaling (I.257 A)
|
||
|
V(R) Receive Sequence Counter
|
||
|
V(S) Transmit Sequence Counter
|
||
|
VAC Vacuumschmelze (produces cores and transformers)
|
||
|
VANS Value Added Network Service
|
||
|
VAP Value Added Process
|
||
|
VAP Videotext Access Point
|
||
|
VC Virtual Call
|
||
|
VCB Virtual Circuit Bearer
|
||
|
VFAC Verified and Forced Account Codes
|
||
|
VFN Vendor Feature Node
|
||
|
VHDL Very High Scale IC Description Language (DOD)
|
||
|
VL (Ger) connecting cable
|
||
|
VPT Virtual Private Network
|
||
|
VSAT Very Small Aperture Terminal (for satellite communication)
|
||
|
VSP (Ger) full frame storage
|
||
|
VSt (Ger) exchange unit
|
||
|
VT Vertical Tabulator
|
||
|
VT Virtual Terminal
|
||
|
VTAM Virtual Telecom Access Method
|
||
|
WADS Wide Area Data Service
|
||
|
WATS Wide Area Telephone Service
|
||
|
WCI Write Controller Interface (IOM2 Monitor Command)
|
||
|
WDFHP recursive high pass filter + decimation filter
|
||
|
WDFLP recursive low pass filter + decimation filter
|
||
|
WDM Wavelength Division Multiplex
|
||
|
XAD Transmit Adress
|
||
|
XFIFO Transmit FIFO
|
||
|
XID Exchange Identification (LAP-D Command/Response)
|
||
|
XOFF Transmission Off (DC1)
|
||
|
XON Transmission On (DC3)
|
||
|
XPL Cross Reference Protocol Listing (PCT)
|
||
|
ZCS Zero Code Suppression
|
||
|
ZSP (Ger) intermediate (buffer) storage
|
||
|
ZWR (Ger) intermediate regenerator
|
||
|
ZZF (Ger) central office for approvals in telecommunications (DBP)
|
||
|
ZZK (Ger) central signaling channel
|
||
|
|
||
|
|
||
|
|