AST RESEARCH, INC. TECHNICAL BULLETIN #0719 11-07-91
=============================================================================
AST ETHERNODE AND SMC CONCENTRATORS/HUBS
PROBLEM: When connecting multiple NetWare servers using SMC's (Standard
Microsystems Corporation) Concentrators/hubs, the error "file
server not found" is displayed on the workstation. If only
one file server is connected, a connection can be made.
CAUSE: SMC has a documented bug which does not allow connecting
multiple servers via their earlier concentrators/hubs.
SOLUTION: Customers experiencing this problem should contact SMC for an
upgrade to a revision G or higher.