textfiles/computers/ASTRESEARCH/0246.tb

28 lines
1.0 KiB
Plaintext
Raw Permalink Normal View History

2021-04-15 11:31:59 -07:00
AST RESEARCH TECHNICAL BULLETIN TB-0246 11/19/86
AST-3G PLUS/MEMORY ERROR MESSAGE
A problem has been discovered when using AST-3G Plus
emulation when the board is installed in IBM Model 339 AT or
compatible PC's. This problem could occur in either "CGA"
or "HERCULES/PREVIEW" emulation modes.
The problem occurs when the PC is warm booted. On a cold
boot the problem does not occur. Depending on the type of
machine, either the message "CONFIGURATION TOO LARGE FOR
MEMORY" or "PARITY CHECK TWO" will appear after a warm boot.
The PC will "lock" and will have to be powered down.
To prevent this from occuring, AST-3G diagnostics diskette
version 2.26 is required. After cold booting the machine,
run the program "EMUL ON", which is contained on the
diagnostics diskette. This will load a keyboard intercept
routine, which will prevent the memory error from occuring
after a warm boot. This program must be run every time the
machine is powered on to prevent the recurrence of the
problem.