AST RESEARCH TECHNICAL BULLETIN TB-0210A 09/19/86
|
|||
|
|
|||
|
|
|||
|
AST3270/FTS-C / TELEX 3274 CONTROLLERS
|
|||
|
|
|||
|
|
|||
|
|
|||
|
The purpose of this Technical Bulletin is to help the user of
|
|||
|
AST3270/FTS-C resolve a "nanoprocessor error" when connected to a
|
|||
|
Telex controller.
|
|||
|
|
|||
|
Utilizing AST3270/FTS-C Version 1.15 with the standard ASTPCOX
|
|||
|
and AST3270 COAX, 1A board, a problem can occur connected to a
|
|||
|
Telex 3274 controller. When FTS-C is executed, it will report a
|
|||
|
"nanoprocessor error" and abort to DOS. This happens due to an
|
|||
|
incompatibility between the 1A board and Telex controllers.
|
|||
|
|
|||
|
To resolve the conflict, an exchange of boards will be required.
|
|||
|
The board which will operate in this environment is the 1B board
|
|||
|
available in the AST3270 COAX / with IRMA product, and the
|
|||
|
ASTPCOX / with IRMA product. Call Technical Support to obtain a
|
|||
|
Return Authorization Number for the exchange of the board. This
|
|||
|
is a no cost exchange and the user will have all the functions of
|
|||
|
the standard AST3270 products along with additional features.
|
|||
|
|